100 ELEVATORS EXAM WITH 100% CORRECT ANSWERS 2023, Exams of Advanced Education

100 ELEVATORS EXAM WITH 100% CORRECT ANSWERS 2023 Elevators are subject to malfunction from the effects of? - Correct Answer-Heat, smoke, and water on the drive machinery/controls What code provides the requirements for the operation of elevator under fire and emergency conditions? - Correct Answer-Title 24; California administrative code What 3 requirements is the building elevator required to have according to the title 24 of the California administrative code for the operation of elevators under fire and emergency conditions? - Correct Answer-1. Designated level- the floor the elevator will be recalled on 2. Elevator emergency service- recall/override capability 3. Smoke detectors- a smoke detector installed adjacent to the elevator, usually in the vestibule on each floor The smoke detectors are required to be installed near an elevator, usually the vestibule area, what is the exception? - Correct Answer-Lobby What phase is the recall phase? - Correct Answer-Phase 1

Typology: Exams

2023/2024

Available from 08/12/2024

professoraxel
professoraxel 🇺🇸

3.7

(28)

10K documents

1 / 5

Toggle sidebar

Related documents


Partial preview of the text

Download 100 ELEVATORS EXAM WITH 100% CORRECT ANSWERS 2023 and more Exams Advanced Education in PDF only on Docsity!

100 ELEVATORS EXAM WITH 100%

CORRECT ANSWERS 2023

Elevators are subject to malfunction from the effects of? - Correct Answer-Heat, smoke, and water on the drive machinery/controls What code provides the requirements for the operation of elevator under fire and emergency conditions? - Correct Answer-Title 24; California administrative code What 3 requirements is the building elevator required to have according to the title 24 of the California administrative code for the operation of elevators under fire and emergency conditions? - Correct Answer-1. Designated level- the floor the elevator will be recalled on

  1. Elevator emergency service- recall/override capability
  2. Smoke detectors- a smoke detector installed adjacent to the elevator, usually in the vestibule on each floor The smoke detectors are required to be installed near an elevator, usually the vestibule area, what is the exception? - Correct Answer-Lobby What phase is the recall phase? - Correct Answer-Phase 1 What happens during the recall phase? - Correct Answer-Elevators will respond non- stop to the lobby/designated area and ignore all other button requests Elevators traveling more than 50' ( more than 25' if new after oct. '75) may be recalled to the lobby what 2 devices? - Correct Answer-Sensing devices (smoke detectors), or by a 3 position key operated switch in the lobby ( emergency service) A minimum of ____ switch is required per bank is required. - Correct Answer- Normally the building control station is required ______________ in the area of the elevator banks. - Correct Answer-Same floor If the building control station is located on the same floor as the elevator banks, where else could the "emergency service" switch to located? - Correct Answer-Located inside the building control station as opposed to the lobby What is phase II? - Correct Answer-Override phase All elevators having a travel of __________ above the lowest grade level, may be recalled to the lobby by _____ or ________ switch in the lobby. - Correct Answer-70' or more, smoke detectors or 3 position " emergency switch "

What are the 3 positions of the " emergency service " switch? - Correct Answer-On-off- hold Turning both switches ( in car, and lobby switches) " on " operates what phase? - Correct Answer-OVERRIDE PHASE Elevator ascent during investigations or firefighting operations shall only be used when the reporting location is above the _______ floor. - Correct Answer- Elevators should not be taken closer than ____ floors below the fire floor or ______ floors below the lowest indicated alarm floor. - Correct Answer-2, 2 When can elevators be taken below grade? - Correct Answer-If deemed safe for use by fire dept members making a visual assessment of conditions that may affect elevator use. Even if the elevators are automatically recalled, the ________________ shall be activated. - Correct Answer-Lobby elevator recall switch True or false: The use of an elevator not equipped with emergency firefighter service or a freight elevator can be utilized? - Correct Answer-False, under no circumstances can a elevator without a emergency firefighter service or a freight elevator be utilized, unless determined safe by fire department personnel on the desired floor and their use approved by IC When can you use a split bank elevator? - Correct Answer-Only if a lower bank of elevators reaches within 5 floors of the fire floor Elevators that travel through a " blind shaft " should be ______ whenever possible. - Correct Answer-Avoided What tools are used to search the elevator and shaft for smoke, fire, and water before use? - Correct Answer-Flashlight, thermal imaging camera When utilizing an elevator for ascent, all members shall have 6 items with them. - Correct Answer-1. Full turnout ( personal protective equipment)

  1. Donned scba, and prepared to connect if idlh is encountered
  2. Portable radio
  3. Sound powered phone
  4. Forcible entry tool
  5. Equipment for fire suppression operations What extinguishing agent shall remain in the elevator car with the elevator operator? - Correct Answer-Dry chemical extinguisher

Fire attack team shall consist of a minimum of ___ members. - Correct Answer- What is the max personnel that can be in any 1 elevator with equipment? - Correct Answer- What is the minimum amount of fire personnel allowed in a elevator? - Correct Answer- 5, 4 for fire attack team, and 1 for elevator operator Members using the elevator for ascent should also determine the location of ________ in relationship to the elevator. - Correct Answer-Stairways If an engine company is first fire suppression resource at a high rise fire, what needs to happen before the elevator can be used to go aloft? - Correct Answer-Need 1 additional personnel from another company to be designated elevator operator Who can be the designated elevator operators? - Correct Answer-A member of a fire suppression company or from a fire suppression certified rescue ambulance When utilizing elevators for ascent, personnel shall make precautionary stops every ______ floors in order to test and confirm that the elevator is properly operating in the phase II MODE. - Correct Answer- What 5 things will the precautionary stops ensure? - Correct Answer-1. Stops at desired floors

  1. Elevator doors remain closed when elevator stops
  2. Doors open only when the door open button is activated
  3. Doors close when the door open button is released
  4. Performing in phase II operations as designed What should happen when the " emergency switch " is turned on? - Correct Answer-All elevators in the bank will be recalled to the lobby floor and remain there with their doors open What should be done even if the elevators are at the lobby floor with their doors open? - Correct Answer-The " emergency switch " shall still be activated After the key is turned to the " on " position what safety devices are deactivated? - Correct Answer-Photo-electric beams, and other non mechanical door retraction safety devices If the elevator car is a landing at the time the recall phase is activated , what will the car do? - Correct Answer-Start moving to the lobby as soon as the door closes What is the " bypass position" used for? - Correct Answer-Used during and incident to place the elevators in operation on a temporary basis when the building has been

deemed safe for normal use but there is still some residual smoke to actuate the detectors Is the key remove able in the bypass position? - Correct Answer-No, otherwise it would accidentally be left on and incase of an emergency the detectors will be deactivated Is there a means to bypass the alarm system when a fire protection device cannot be reset if the " emergency service " switch has " reset", " off ", and " on "? - Correct Answer-No, there is no " bypass " position How will the car doors be openable if the key inside the car switch is in the " on " position? - Correct Answer-By the elevator operator inside the car In phase II, how is the opening of the power operated doors function? - Correct Answer- By continuous pressure on the " door open " button What will happen if the " door open " button is released before the doors reach the fully open position? - Correct Answer-The doors will automatically re close What is the exception to the " door open " button being released before the doors are fully open, closing again? - Correct Answer-Upon returning to the lobby If a " closed door " button is not available, what is the operation to close the car doors? - Correct Answer-Continuous pressure on the desired floor If multiple floors are selected ( still phase II) what will the car do? - Correct Answer-The car will stop at the first of the selected floors that it reaches, and all other selections will be cancelled Elevators installed after October 1985 must have a separate " _______ " button for use by emergency personnel - Correct Answer-" call cancel " In either phase I or II, the elevator car(s) may be equipped with an " _______________ " mode with or without _______ devices for fire related emergencies. - Correct Answer-" Independent service ", photo-electric ________ use the " independent service " mode - Correct Answer-DO NOT While the car is used in " independent service " mode, they are _____ subject to recall by sensing device or the key operating switches - Correct Answer-Not Under emergency conditions, depressing the " door close " button will cause the door to close, but only after they have reached ____________ position. - Correct Answer-The fully open

If elevators are in recall phase, will returning the elevator car to automatic operation from " independent service ", place the car in recall phase? - Correct Answer-Yes In phase I ( recall ) or phase II ( override ) modes, if for any reason an emergency occurs while you are in the elevator car and the sensing devices don't work, what are the procedures? - Correct Answer-1. In automatic mode (w/o photoelectric devices) depress the " door close " button, but only after they have reached their fully open position

  1. In automatic mode ( w/ photoelectric devices ) it's possible that the photoelectric beam may be blocked by smoke causing the car doors to stay open, drepress the switch marked " TO BE USED IN CASE OF FIRE ONLY ", this action will cause the door to close When should the " emergency stop " button be used? - Correct Answer-As a last resort When the switch is in the " on " position, is the key removable? - Correct Answer-Yes The elevator operator will report and maintain communications with? - Correct Answer- Lobby control Who ultimately determines the use of elevators? - Correct Answer-Fire department personnel The initial fire attack team traveling in elevator cars must be equipped with what equipment? - Correct Answer-Full PPEs, scba, forcible entry tool, dry chemical extinguisher, firefighting hose lines, thermal imaging camera, portable radio