A comprehensive set of practice questions and verified answers for the 3rd class stationary steam engineer license exam. It covers a wide range of topics related to boiler operation, steam generation, and safety procedures. The questions are designed to test the understanding of fundamental concepts and practical applications in the field of stationary steam engineering.
Typology: Exams
1 / 19
_________ are necessary for complete combustion - Correct answer time, temperature, mixture, and atomization if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - Correct answer 214. A boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes at 398 PSI. The blow down is______psi - Correct answer 12 an oil cooler is commonly used with a(n) ________ when operating in conjunction with a turbo-generator - Correct answer steam turbine A boiler is producing 40,000lb of steam/hr. at a pressure of 100 PSI and a steam temperature of 500 degrees Fahrenheit. The steam produced is _______ steam - Correct answer superheated the economizer on a boiler is used to _______ - Correct answer add heat to the feed water blowers are normally used with________ boilers - Correct answer water tube overheating of tubes on a boiler can be caused by________ - Correct answer scale on tubes carbon dioxide in a condensate return system causes_________ - Correct answer channeling a ________ pump is a positive displacement pump - Correct answer reciprocating a boiler generating 6000 lb. of steam/hr. produces _______but/hr. - Correct answer 6,000, a bottom blow down is performed on a boiler to _____ - Correct answer discharge sludge and sediment
water columns are connected to the boiler with a minimum of _______" pipe - Correct answer 1 The minimum size of a water column blow down valve is_______". - Correct answer 3/ The maximum size bottom blow down valve on a boiler is_________". - Correct answer 2 1/ A ________ allows condensate to pass through, but stops Steam. - Correct answer a steam trap when taking over a shift, the first thing to do is check the________ - Correct answer water level in each boiler according to the same code, a high-pressure boiler having more than 500 square feet of heating surface shall have________ - Correct answer two or more safety valves the probable cause of an increase in temperature of gases of combustion at the boiler Outlet is____ - Correct answer dirty heating services boilers in battery equipped with________ must have two main steam stop valves and a free-flowing drain between them - Correct answer manhole openings in order to be sure the gauge glass is indicating an accurate water level reading, the stationary engineer should______ - Correct answer blow down the gauge glass a continuous blow down line is located___ - Correct answer in the Steam and water drum well below the now a temperature reading of 80 degrees Celsius is equal to_________°f - Correct answer 176 a chimney temperature of 250 degrees Fahrenheit above steam temperature indicates_______ - Correct answer poor efficiency a manometer is red in________ - Correct answer inches of water the boiling point of water will____ with an increase in pressure - Correct answer be raised
hard scale formed on the inside of tubes is best removed by________ - Correct answer air- or water-driven turbines to correct a low water condition,_____ - Correct answer secure fires desuperheater drain is used to_______ - Correct answer establish steam flow a sudden rise in chimney temperature with no increase in load indicates______ - Correct answer there is a broken baffle the but content of natural gas is_____ - Correct answer 100,000 but/thermo the safety valve setting on the Steam and water drum is ________ a superheated safety valve - Correct answer higher than The but content of number 6 fuel oil is approximately - Correct answer 18750 BTU / lb. chemicals can be added to a boiler by a______pump - Correct answer proportioning the feed water stop valve is found between the____ - Correct answer boiler and check valve sensible heat is______ - Correct answer heat that can be measured with a thermometer balanced draft is______ - Correct answer constant furnace pressure slightly below atmospheric pressure a flame rod_______ - Correct answer ensures that the gas pilot is lighted there are approximately_____but in 1 cu ft. of Natural Gas - Correct answer 1000 the pH of boiler water may be controlled by using ______ - Correct answer caustic soda boiler water with a pH of 11 is________ - Correct answer alkaline a scotch Marine boiler is easily identified because it_____ - Correct answer has a cylindrical internal furnace
the air flow switch at the burner fan housing________ - Correct answer and shows the primary air fan is functioning the same code recommends that low water fuel cutoff switch be tested by an evaporation test__________ - Correct answer monthly a neutral solution is_______ on the pH scale - Correct answer 7 a dry pipe separator _____ - Correct answer delivers higher-quality steam to the header draft is carefully controlled to_____ - Correct answer completely burn fuel supplied to the burner draft is measured with a_________ - Correct answer manometer a rangeland test is used to determine_______ - Correct answer smoke density a flame scanner proves (verifies) __________ - Correct answer pilot in Maine Flame according to the same code, when warming up a boiler the air cock is closed when_______ - Correct answer the steam pressure gauge reads 25 psi a motor rated at 25 horsepower delivering 20 horsepower is operating at_______% capacity - Correct answer 80 a deposit of scale or mud in an HRT boiler could cause_____ - Correct answer a bag to develop water wall tubes protect the refractory and_____ - Correct answer increase boiler heating surface steam at E250 Pisa and 400 degrees Fahrenheit is considered______ Steam - Correct answer saturated sensible heat is heat that_____ - Correct answer changes a substances temperature but not its state extra-heavy pipe must be used on blow down lines when the steam pressure exceeds______ psi - Correct answer 125
as steam pressure in a boiler increases, there is a corresponding increase in the ______ - Correct answer temperature of steam and water the safety valve on a boiler _____ - Correct answer prevents the boiler from exceeding its map a steam trap ______ - Correct answer automatically remove sand and water without loss of steam the amount of excess air in gases of combustion is normally determined by the analysis of______ - Correct answer O before lighting off a boiler during a cold startup, the operator must first______ - Correct answer check for the correct water level boiler should be warmed up slowly when starting up to ______ - Correct answer allow uniform expansion of drums and tubes combustion requires____ - Correct answer fuel, oxygen, and Heat the three most common fuels used in boilers are _____ - Correct answer gas, fuel oil, and Coal incomplete combustion can be caused by ______ - Correct answer insufficient air after replacing a gauge glass but before placing it in service, it is necessary to ______ - Correct answer crack open the steam valve in warm the gauge glass two bottom blow down valves are required on boilers operating at pressures above______ psi - Correct answer 100 extra heavy steel pipe is required on a boiler bottom blow down line when the pressure is above ____ psi - Correct answer 125 package boilers are programmed to _____ - Correct answer ignite the burner in low fire there are________ sq. ft. of heating surface in a water tube 3 1/2" in diameter and 20' long - Correct answer 18.
to change 1 lb. of water from and at212 °f into steam at atmospheric pressure,______ but are necessary - Correct answer 970. a surface condenser is one that______ - Correct answer has circulating water flowing through the tubes and exhaust steam around the outside of the tubes A boiler is rated at 30,000 lb. /hr. and has a 5% blow down loss. The minimum size feed water pump to supply this boiler is ________ gal./hr. - Correct answer 3795 three types of draft used in power plants are______ - Correct answer natural, forest, and induced in a water tube boiler, heat and gases of combustion pass______ - Correct answer around the tubes when the burner is in high fire, the______ - Correct answer air-fuel ratio is at maximum rate a boiler with a draft gauge showing a positive pressure indicates_____ - Correct answer furnace pressure is above atmospheric pressure down comer tubes are found _____ - Correct answer in a water tube boiler a boiler connected in battery requires a free blowing drain between the two stop valves when the ______ - Correct answer boiler has a manhole opening most furnace explosions are caused by _____ - Correct answer failure to purge the furnace at startup baffles in the boiler are designed to direct gases of combustion for close contact with the ________ - Correct answer boiler heating surface the over speed tripping device on a steam turbine must be tripped when____ - Correct answer shutting down the steam turbine one gallon of no. 6 fuel oil weighs approximately _______ lb. - Correct answer 8. three types of boiler feed water pumps are _____ - Correct answer reciprocating, centrifugal, and turbine
listing lovers on safety valves are used to_____ - Correct answer manually test valves the frequency of performing a bottom blow down is determined by ______ - Correct answer boiler Water Analysis normally a water column and gauge glass should be blown down _____ - Correct answer at the start of a shift in whenever and out of the water level a thermostatic trap opens when the____ - Correct answer the Bellows contract an economizer located in the path of the gases of combustion increased boiler efficiency approximately 1% for each ___°f rise in feed water temperature - Correct answer 10 the purpose of a vent on the open feed water heater is to _____ - Correct answer remove oxygen and non-condensable gases steam pressure gauges are calibrated in____ - Correct answer pounds per square inch bottom blow down lines are located______ - Correct answer at the lowest part of the water side of the boiler sewer lines are protected from pressure and temperature by the _______ when blowing down a boiler - Correct answer blow down tank The upper connection to a gauge glasses closed. If the boiler has a normal water level, the level on the gauge glass will show _______ glass - Correct answer full combustion controls on a boiler are used to _____ - Correct answer control the air fuel ratio ceiling strips that warned of excessive radial tolerance are found on_____ - Correct answer steam turbines pre-purge, air to fuel ratio, and post Purge of the burner are functions of the _______ - Correct answer combustion controls a water column______ - Correct answer reduces fluctuations of water in the gauge glass
the low water fuel cutoff can be tested by _____ - Correct answer allowing the water level to drop boilers that are equipped with air heaters and economizers usually have_____ draft fans - Correct answer forced and induced baffles are used in the Steam and water drum of water tube boilers to _____ - Correct answer prevent water carry over with the steam a closed feed water heater is always installed_______ - Correct answer on the discharge side of the feed water pump the purpose of a burner pressure control is to _____ - Correct answer start and stop the burner firing cycle a gas pressure regulator is used to control the ______ - Correct answer gas pressure at the burner if the chimney temperature is 250 degrees Fahrenheit higher than the Steam and water temperature, the boiler is _______ - Correct answer not operating efficiently the most controllable heat loss in a boiler is from the loss of heat in______ - Correct answer gases of combustion on the feed water line, the valve closest to the boiler shell is a _____ valve - Correct answer stop four basic systems found on boilers are ______< - Correct answer steam, feed water, fuel, and draft if a low-water condition occurs, the operator should first _______ - Correct answer secure the burners A pressure control on a boiler is used to. _______ - Correct answer control the operating range of the boiler sup blowers are most commonly found ______ - Correct answer on water tube boilers
electrostatic precipitators are used in the power plants to ________ - Correct answer remove fly ash from gases of combustion valve located between the boiler and water column must be ______ - Correct answer locked or sealed open The boiling point of water. ________ with an increase in pressure - Correct answer increases a hole is drilled in the end of a stay bolt _______ - Correct answer to warn of a corroded stay When taking a boiler off line, a vacuum is prevented by. _____ - Correct answer opening the air cock a valve that requires five 360° turns of the hand wheel to change from fully open to fully closed is a. _______ valve - Correct answer slow opening a thermostatic steam trap opens when the ______ - Correct answer Bellows contract A combustion control on a boiler. _______ - Correct answer controls the air-fuel ratio when coal is classified, ________ refers to hardness - Correct answer rank _______ gauge glasses are used on boilers with precious exceeding 250 psi - Correct answer flat oxygen and non-condensable gases are removed from feed water by ________ - Correct answer heating the water __________ combustion is when all fuel is burned using only the theoretical amount of air - Correct answer perfect Water tube boilers require less water than. _________ boilers - Correct answer fire tube A boiler equipped with a draft gauge and registering a negative pressure indicates. _________ - Correct answer atmospheric pressure is greater than furnace pressure
pressure atomizing burners atomized fuel oil using _______ - Correct answer a nozzle The. _________ on the steam turbine functions as a limit switch - Correct answer over speed trip Circulating water passes through a surface condenser. ________ - Correct answer inside the tubes The Pour point of a fuel oil is. ________ - Correct answer the lowest temperature at which oil will flow A condensate pump is located 75 ' below the feed water heater and its discharged gauge reads 75 PSI. The pressure at the inlet to the heater is. _______ psi - Correct answer 42. A boiler burning fuel oil and using forced-draft requires. ________ cu ft. a furnace volume per boiler horsepower - Correct answer. A boiler evaporates 48,000 lb. of steam/hr. it evaporates 12 lb. of steam/sq. ft. of heating surface per hour. The boiler has _______ as ft. of heating surface - Correct answer 4000 a steam turbine exhaust end and condenser are prevented from excess pressure by ________ - Correct answer the atmospheric relief valve at 0 psi, _______ but are necessary to change 1 lb. of water from and at 212°f into steam - Correct answer 970. automatic toilets are program to ignite the burner ______ - Correct answer in low fire ________ boilers can operate at higher pressures than fire tube boilers - Correct answer water tube the first step when using a soot blower is ________ - Correct answer open Steam line drain the purpose of a vent on an open feed water heater is to _______ - Correct answer remove air and other non-condensable gases
the tubes in a water tube boiler are fastened by ______ - Correct answer rolling and expanding in drums and headers a dry pipe separator in a boiler _______ - Correct answer maintains a high-quality Steam a (n) ________ valve offers the least resistance to flow - Correct answer gate if valves are installed between the boiler and water column, they must be _______ - Correct answer soy or lever-type, locked or chained open steam withdrawn from a steam turbine under pressure control is __________ Steam - Correct answer extraction in a closed feed water heater, the_______ - Correct answer Steam and water do not mix a compound gauge registers ________% - Correct answer either vacuum or pressure a Norse that analyzer measures _________ in gases of combustion - Correct answer carbon dioxide, oxygen, and carbon monoxide the pyrite analyzer can be used to measure - Correct answer oxygen automatic combustion controls on a boiler control _______ - Correct answer Fuel and air ratio if the firing rate increases on a boiler equipped with a convection type superheated, the superheated temperature will________ - Correct answer increase a thermostatic steam trap can be used _________ - Correct answer on high or low pressure systems heat that changes the temperature of a substance but not its state is_________ - Correct answer sensible heat _________is carrying over particles of water with the steam - Correct answer priming
if a boiler is equipped with an automatic non-return valve, it must be _______ - Correct answer the valve closest to the boiler shell a broken baffle on a water tube boiler would cause ________ - Correct answer increase in chimney temperature a feed water pump will become steam bound if the ________ - Correct answer water temperature in the open feed water heater is too high overheating of tubes in a water tube boiler result if_________ - Correct answer scale builds up on the inside of the tubes complete combustion occurs when ______ - Correct answer all combustible material is burned with a minimum of excess air according to the same code, the adjusting of safety valves should be done by the ______ - Correct answer manufacturer or authorized representative in a steam generating plant, the economizer is used to _______ - Correct answer heat feed water when testing a safety valve by hand, the pressure on the boiler should be at least ___________% are the safety valve set pressure - Correct answer 75 heat absorbed by water when changing from liquid to steam at the boiling point is ______ - Correct answer latent heat to raise the temperature of 1 lb. of water from 32°f to 212°f, ________ but are needed - Correct answer 180 baffles are placed between the tubes of a boiler to _________ - Correct answer direct the travel of gases of combustion In a pressure atomizing fuel oil burner, atomization of fuel oil is produced by the. _________ - Correct answer burner tip and high fuel oil pressure The steam Inlet connections of a condenser should be provided with. _______ - Correct answer an atmospheric relief valve
feed water is treated chemically before it enters the boiler drum to ________ - Correct answer change scale forming salts to a non-adhering sludge