BACKFLOW PREVENTION ASSEMBLY

TESTER EXAM (BPAT)

WHICH OF THE FOLLOWING CONDITIONS COULD RESULT IN WATER

CONTAMINATION THROUGH A CROSS-CONNECTION? - A) A VACUUM

CREATED BY THE IMPROPER USE OF WATER HAMMER ARRESTERS

B) THE USE OF SELF CLOSING LAVATORY FAUCETS

C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND

ALLOWING THE WATER SUPPLY TO DRAIN

D) A VACUUM CREATED BY THE USE OF QUICK CLOSING VALVES ON

THE LOWER FLOORS OF A BUILDING EXCEEDING TEN (10) FLOORS IN

HEIGHT

E) THE INSTALLATION OF WATER CONSERVING FIXTURES, INTO A

BUILDING DESIGNED PRIOR TO THEIR REQUIRED USE

C) TURNING OFF SERVICE TO A MULTI-STORY BUILDING AND

ALLOWING THE WATER SUPPLY TO DRAIN

WHAT IS ANOTHER TERM THAT DESCRIBES WATER QUALITY AS A

HEALTH HAZARD RESULTING FROM BACKFLOW? - A) ISOLATION

B) CONTAMINATION

C) CROSS-CONNECTION

D) POLLUTION

E) CONTAINED

B) CONTAMINATION

THE VENTURI EFFECT STATES THAT WHEN THE WATER VELOCITY

WITHIN THE PIPE INCREASES, THE PRESSURE: - A) WILL INCREASE

PROPORTIONATELY

B) WILL REMAIN CONSTANT

C) COMPRESSES EXCESS VOLUMES OF WATER

D) DECREASES

E) CREATES BACKPRESSURE

D) DECREASES

THE DEGREE OF HAZARD IS: - A) THE ACCEPTABLE TEMPERATURE

RANGE OF A NON-POTABLE WATER SOURCE

B) THE ANGLE OF THE BACKFLOW PREVENTER

C) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE

D) DISTANCE BETWEEN THE CROSS-CONNECTION AND THE BACKFLOW

PREVENTER

E) THE ENGINEER'S SPECIFIED ELEVATION OF NON-POTABLE PIPING

C) BASED UPON THE QUALITY OF A NON POTABLE WATER SOURCE

BACKFLOW MAY BE DESCRIBED AS EITHER: - A) BACKPRESSURE OR

BACKSIPHONAGE

B) CONTAMINATION OR POLLUTION

C) CONTAINMENT AND ISOLATION

D) DIRECT AND/OR INDIRECT

E) HIGH TEMPERATURE OR LOW TEMPERATURE

A) BACKPRESSURE OR BACKSIPHONAGE

THE FEDERAL LAW PLACING RESPONSIBILITY FOR THE PROTECTION OF

THE PUBLIC WATER SUPPLY ON THE PURVEYOR OF WATER IS THE: - A)

ENVIRONMENTAL PROTECTION AGENCY'S PRIMARY DRINKING WATER

REGULATIONS

B) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

REGULATIONS

C) SAFE DRINKING WATER ACT

D) FOOD AND DRUG ADMINISTRATION'S UNIFORM PLUMBING CODE

E) CLEAN WATER ACT

C) SAFE DRINKING WATER ACT

HOW MANY INCHES MUST A PRESSURE TYPE VACUUM BREAKER

ASSEMBLY BE INSTALLED ABOVE ALL DOWNSTREAM PIPING? - A) SIX (6)

B) TWELVE (12)

C) EIGHTEEN (18)

D) TWENTY-FOUR (24)

E) ONE (1)

B) TWELVE (12)

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY WILL PROTECT

THE POTABLE WATER SUPPLY FROM: - A) NON-HEALTH HAZARD -

BACKSIPHONAGE

B) NON-HEALTH HAZARD - BACKPRESSURE

C) NON-HEALTH HAZARD - BACKPRESSURE AND BACKSIPHONAGE

D) HEALTH HAZARD - BACKSIPHONAGE

E) HEALTH HAZARD - BACKPRESSURE

C) NON-HEALTH HAZARD - BACKPRESSURE AND BACKSIPHONAGE

HOW MANY INCHES MUST AN ATMOSPHERIC VACUUM BREAKER BE

INSTALLED ABOVE ALL DOWNSTREAM PIPING AND HIGHEST OPENING?

- A) SIX (6)

B) NINE (9)

C) TWELVE (12)

D) EIGHTEEN (18)

E) ONE (1)

A) SIX (6)

AN ATMOSPHERIC VACUUM BREAKER IS INSTALLED TO PROTECT

AGAINST: - A) BACKPRESSURE - NON-HEALTH HAZARD CONDITIONS

ONLY

B) BACKPRESSURE - HEALTH HAZARD CONDITIONS ONLY

C) BACKSIPHONAGE - NON-HEALTH HAZARD CONDITIONS ONLY

D) BACKSIPHONAGE - HEALTH HAZARD CONDITIONS ONLY

E) BACKSIPHONAGE - HEALTH HAZARD OR NON-HEALTH HAZARD

CONDITIONS

E) BACKSIPHONAGE - HEALTH HAZARD OR NON-HEALTH HAZARD

CONDITIONS

THE TERM "APPROVED REDUCED PRESSURE PRINCIPLE ASSEMBLY",

APPLIES TO AN ASSEMBLY WITH TWO SHUT-OFF VALVES, FOUR TEST

COCKS AND: - A) TWO CHECK VALVES AND AN AIR INLET VALVE

B) TWO APPROVED CHECK VALVES AND AN AIR INLET VALVE

C) TWO APPROVED CHECK VALVES AND A PRESSURE RELIEF VALVE

D) TWO APPROVED CHECK VALVES AND A DIFFERENTIAL PRESSURE

RELIEF VALVE

E) TWO APPROVED CHECK VALVES AND A PRESSURE REGULATING

VALVE

D) TWO APPROVED CHECK VALVES AND A DIFFERENTIAL PRESSURE

RELIEF VALVE

IT IS REQUIRED THAT THE TEST GAUGE BE TESTED FOR ACCURACY AT

LEAST: - A) MONTHLY

B) QUARTERLY

C) SEMI-ANNUALLY

D) ANNUALLY

E) AT THE TIME OF PURCHASE AND PRIOR TO EACH USE FOR TESTING

D) ANNUALLY

UNDERSIZED WATER PIPING CARRYING WATER AT HIGH VELOCITY CAN

CAUSE BACK-SIPHONAGE DUE TO: - A) THE VACUUM EFFECT

B) THE PIVOT EFFECT

C) THE MARGINAL EFFECT

D) THE ASPIRATOR EFFECT

E) THE VELOCITY EFFECT

D) THE ASPIRATOR EFFECT

AN AIR GAP SEPARATION IS MEASURED FROM THE OUTLET OF THE

DISCHARGE PIPE, TO THE: - A) FIXTURE DRAIN PLUG

B) INLET OF THE SUPPLY

C) LEVEL OF THE LIQUID

D) FLOOD LEVEL RIM

E) NONE OF THE ABOVE

D) FLOOD LEVEL RIM

THE MINIMUM TYPE OF CONTAINMENT PROTECTION FOR A NON-

HEALTH HAZARD, NON-CHEMICAL FIRE SPRINKLER SYSTEM IS A(N): - A)

ATMOSPHERIC VACUUM BREAKER

B) DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER

C) PRESSURE VACUUM BREAKER ASSEMBLY

D) REDUCED PRESSURE DETECTOR ASSEMBLY

E) ALL OF THE ABOVE

B) DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER

THE TYPE OF PROTECTION REQUIRED FOR A CLOSED LOOP HEATING

SYSTEM CONTAINING CHEMICALS IS: - A) REDUCED PRESSURE

PRINCIPLE ASSEMBLY

B) DOUBLE CHECK VALVE ASSEMBLY

C) PRESSURE VACUUM BREAKER ASSEMBLY

D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER

E) ALL OF THE ABOVE

A) REDUCED PRESSURE PRINCIPLE ASSEMBLY

FOR CONTAINMENT PROTECTION IN A NON-HEALTH HAZARD

SITUATION, THE MINIMUM PROTECTION REQUIRED SHALL BE: - A)

REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER

B) TWO (2) SINGLE CHECK VALVES IN SERIES

C) DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY

D) ATMOSPHERIC VACUUM BREAKER

E) NONE OF THE ABOVE

C) DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY

WATER CONTINUOUSLY LEAKING FROM TEST COCK #2 DURING A TEST

PROCEDURE OF A PRESSURE VACUUM BREAKER ASSEMBLY IS

PROBABLY CAUSED BY A LEAKING: - A) AIR INLET VALVE

B) TEST COCK

C) INLET SHUT-OFF VALVE

D) OUTLET SHUT-OFF VALVE

E) TEST COCK

C) INLET SHUT-OFF VALVE

THE REQUIRED BACKFLOW PREVENTION ASSEMBLY FOR A FIRE

SUPPRESSION SYSTEM CONTAINING CHEMICALS IS: - A) REDUCED

PRESSURE DETECTOR ASSEMBLY OR REDUCED PRESSURE PRINCIPLE

ASSEMBLY

B) DOUBLE CHECK DETECTOR ASSEMBLY OR DOUBLE CHECK BACKFLOW

PREVENTION ASSEMBLY

C) PRESSURE VACUUM BREAKER ASSEMBLY

D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER

E) NONE OF THE ABOVE

A) REDUCED PRESSURE DETECTOR ASSEMBLY OR REDUCED PRESSURE

PRINCIPLE ASSEMBLY

THE REQUIRED TYPE OF BACKFLOW PROTECTION FOR A CLOSED LOOP

PIPING SYSTEM CONTAINING GLYCOL IS: - A) DOUBLE CHECK VALVE

ASSEMBLY

B) REDUCED PRESSURE PRINCIPLE ASSEMBLY

C) ATMOSPHERIC VACUUM BREAKER

D) DUAL CHECK VALVE TYPE BACKFLOW PREVENTER

E) NONE OF THE ABOVE

B) REDUCED PRESSURE PRINCIPLE ASSEMBLY

THE PRIMARY CONSIDERATION IN DETERMINING WHAT TYPE OF

BACKFLOW PREVENTER TO INSTALL IS: - A) COST

B) CUSTOMER PREFERENCE

C) DEGREE OF HAZARD

D) SYSTEM TEMPERATURE

E) PERSONAL PREFERENCE

C) DEGREE OF HAZARD

WHAT IS THE PROBABLE CAUSE OF A RELIEF VALVE FAILING TO OPEN

DURING A FIELD TEST ON A REDUCED PRESSURE PRINCIPLE BACKFLOW

PREVENTER? - A) A LEAKING #1 SHUT-OFF VALVE

B) LOW WATER SUPPLY PRESSURE

C) AIR TRAPPED INSIDE THE RELIEF VALVE

D) EXCESSIVE BACKPRESSURE

E) A MALFUNCTION OF THE RELIEF VALVE MECHANISM

E) A MALFUNCTION OF THE RELIEF VALVE MECHANISM

THE REQUIRED BACKFLOW PROTECTION FOR A CHEMICALLY CHARGED

SOLAR HEATING SYSTEM WITH AN EXPANSION TANK IS A(N): - A)

REDUCED PRESSURE PRINCIPLE ASSEMBLY

B) ATMOSPHERIC VACUUM BREAKER

C) DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY

D) PRESSURE VACUUM BREAKER ASSEMBLY

E) NONE OF THE ABOVE

A) REDUCED PRESSURE PRINCIPLE ASSEMBLY

THE TYPE OF PROTECTION ASSOCIATED WITH AN AIR GAP SEPARATION

IS: - A) BACKSIPHONAGE - NON-HEALTH HAZARD

B) BACKSIPHONAGE - HEALTH HAZARD

C) BACKPRESSURE - NON-HEALTH HAZARD

D) BACKPRESSURE - HEALTH HAZARD

E) ALL OF THE ABOVE

E) ALL OF THE ABOVE

THE APPLICATION OF A PRESSURE VACUUM BREAKER ASSEMBLY IS

FOR: - A) BACKPRESSURE AND ISOLATION

B) BACKSIPHONAGE AND ISOLATION

C) BACKPRESSURE OR BACKSIPHONAGE AND ISOLATION

D) CONTAINMENT ONLY

E) NONE OF THE ABOVE

B) BACKSIPHONAGE AND ISOLATION

HOW MANY POUNDS OF PRESSURE PER SQUARE INCH ARE EXERTED AT

THE BASE OF A COLUMN OF WATER THAT IS TWO (2) FEET TALL? - A)

0.

B) 0.

C) 0.

D) 1.

E) 1.

C) 0.

A PRESSURE OF 75 PSI WOULD BE EQUIVALENT TO WHAT _________

HEAD OF WATER? - A) 37.5 FEET

B) 75.0 FEET

C) 115.0 FEET

D) 150.0 FEET

E) 173.2 FEET

E) 173.2 FEET

A PRESSURE GAUGE INSTALLED AT THE BOTTOM OF AN OPEN TANK,

CONTAINING WATER TEN (10) FEET DEEP, WOULD INDICATE WHAT

PRESSURE READING? - A) 4.3 PSI

B) 8.6 PSI

C) 12.2 PSI

D) 14.7 PSI

E) 16.9 PSI

A) 4.3 PSI

WHAT EQUIPMENT IS USED TO TEST A PRESSURE VACUUM BREAKER

ASSEMBLY? - A) ATMOSPHERIC VACUUM GAUGE

B) DUPLEX GAUGE

C) DIFFERENTIAL PRESSURE GAUGE

D) PAIR OF BOURBON GAUGES

E) FORTY-TWO INCH SIGHT TUBE

C) DIFFERENTIAL PRESSURE GAUGE

TEST COCK NUMBER __________ MAY BE OPENED TO ESTABLISH FLOW

THROUGH A BACKFLOW PREVENTION ASSEMBLY: - A) ONE (1)

B) TWO (2)

C) THREE (3)

D) FOUR (4)

E) ALL THE ABOVE

D) FOUR (4)

USC, AWWA AND MANUFACTURERS RECOMMEND THAT BACKFLOW

PREVENTION ASSEMBLIES BE INSPECTED, AND THAT THEIR PROPER

OPERATION IS VERIFIED BY A CERTIFIED TESTER AT LEAST: - A) ONCE

EVERY MONTH

B) ONCE EVERY SIX (6) MONTHS

C) ONCE EVERY YEAR

D) ONCE EVERY TWO (2) YEARS

E) ONCE EVERY THREE (3) YEARS

C) ONCE EVERY YEAR

A DIFFERENTIAL PRESSURE GAUGE IS USED IN THE TESTING OF: - A)

DOUBLE CHECK VALVE ASSEMBLY

B) REDUCED PRESSURE PRINCIPLE BACKFLOW ASSEMBLY

C) DUAL CHECK WITH INTERMEDIATE ATMOSPHERIC VENT

D) BOTH A) AND B)

E) ALL OF THE ABOVE

D) BOTH A) AND B)

FROM THE CHOICES LISTED BELOW, WHAT INFORMATION IS REQUIRED

TO PROPERLY IDENTIFY THE BACKFLOW PREVENTION ASSEMBLY TO BE

TESTED? - A) TYPE AND MANUFACTURER OF BACKFLOW PREVENTION

ASSEMBLY

B) LOCATION AND SIZE OF BACKFLOW PREVENTION ASSEMBLY

C) MODEL AND SERIAL NUMBER OF BACKFLOW PREVENTION

ASSEMBLY

D) ALL OF THE ABOVE

E) BOTH A) AND C)

D) ALL OF THE ABOVE

THE ORIGINAL SIGNED AND DATED TEST REPORT MUST BE: - A) GIVEN

TO THE OWNER OF THE PROPERTY

B) SUBMITTED TO THE WATER PURVEYOR

C) KEPT BY THE TESTER FOR THREE YEARS

D) KEPT BY THE TESTER FOR TEN YEARS

E) NONE OF THE ABOVE

B) SUBMITTED TO THE WATER PURVEYOR

THE CRITICAL FINAL STEP IN TESTING A BACKFLOW PREVENTION

ASSEMBLY IS: - A) REMOVING THE TEST COCK ADAPTERS

B) RETURNING THE ASSEMBLY TO NORMAL OPERATING CONDITION

C) RECORDING THE TEST RESULTS

D) REMOVING THE GAUGES

E) MAKING OUT THE BILL

B) RETURNING THE ASSEMBLY TO NORMAL OPERATING CONDITION

THE DIFFERENTIAL PRESSURE RELIEF VALVE ON A REDUCED PRESSURE

PRINCIPLE BACKFLOW ASSEMBLY MUST OPEN BEFORE THE

DIFFERENTIAL PRESSURE ACROSS THE INLET CHECK VALVE DROPS

BELOW: - A) 1.0 PSID

B) 1.5 PSIA

C) 2.0 PSID

D) 2.5 PSIG

E) NONE OF THE ABOVE

C) 2.0 PSID

THE MINIMUM HOSE DIAMETER FOR A PRESSURE DIFFERENTIAL

GAUGE IS ________ INCH: - A) 1/

B) 1/

C) 3/

D) 1/

E) 3/

B) 1/

WHAT ARE THE MINIMUM SCALE INCREMENTS ALLOWED ON

DIFFERENTIAL PRESSURE GAUGES USED FOR TESTING BACKFLOW

PREVENTION ASSEMBLIES AND DEVICES? - A) 0.1 PSIA

B) 0.2 PSID

C) 0.5 PSIG

D) 1.0 PSID

E) 2.0 PSIA

B) 0.2 PSID

WHAT VALVE MUST BE CLOSED WHEN TESTING A REDUCED PRESSURE

PRINCIPLE BACKFLOW ASSEMBLY? - A) NUMBER ONE (1) SHUT-OFF

VALVE

B) SERVICE CONNECTION VALVE

C) PRESSURE REGULATING VALVE

D) FLOW CONTROL VALVE

E) NUMBER TWO (2) SHUT-OFF VALVE

E) NUMBER TWO (2) SHUT-OFF VALVE

AN OCCASIONAL DISCHARGE FROM THE RELIEF VALVE OF A REDUCED

PRESSURE PRINCIPLE BACKFLOW PREVENTER USUALLY INDICATES: - A)

A LEAKING NUMBER ONE (1) CHECK VALVE

B) A LEAKING NUMBER TWO (2) CHECK VALVE

C) A MALFUNCTION IN THE RELIEF VALVE

D) THE DEVICE IS WORKING PROPERLY

E) AN IMPROPER INSTALLATION

D) THE DEVICE IS WORKING PROPERLY

IF THE CHECK VALVE SPRINGS ARE INTERCHANGED ON A DOUBLE

CHECK VALVE ASSEMBLY, THE ASSEMBLY: - A) WILL NOT PROTECT

AGAINST BACKFLOW

B) WILL CREATE A SIGNIFICANT PRESSURE DROP

C) WILL NOT BE ADVERSELY AFFECTED BY THE INTERCHANGE

D) WILL MALFUNCTION DUE TO THE INTERCHANGE

E) WILL CREATE A STATIC CONDITION

C) WILL NOT BE ADVERSELY AFFECTED BY THE INTERCHANGE

CONSTANT DISCHARGE FROM THE RELIEF VALVE OF A REDUCED

PRESSURE PRINCIPLE ASSEMBLY USUALLY INDICATES: - A)

FLUCTUATING INCOMING PRESSURE

B) A LEAKING NUMBER ONE (1) CHECK VALVE

C) FLUCTUATING DOWNSTREAM PRESSURE

D) EXCESSIVE DOWNSTREAM PRESSURE

E) THE SHUT-OFF VALVES ARE NOT OPEN

B) A LEAKING NUMBER ONE (1) CHECK VALVE

THE REQUIRED NUMBER OF TEST COCKS ON A SMALL (3/4"- 2")

PRESSURE VACUUM BREAKER ASSEMBLY IS: - A) NONE

B) ONE (1)

C) TWO (2)

D) THREE (3)

E) FOUR (4)

C) TWO (2)

THE REQUIRED NUMBER OF TEST COCKS ON A LARGE (2½" - 4")

ATMOSPHERIC VACUUM BREAKER IS: - A) NONE

B) ONE (1)

C) TWO (2)

D) THREE (3)

E) FOUR (4)

A) NONE

WHAT CRITICAL COMPONENT OF AN ATMOSPHERIC VACUUM BREAKER

IS SUBJECT TO FAILURE? - A) UPSTREAM SHUT-OFF VALVE

B) LOADED CHECK VALVE

C) CANOPY

D) AIR INLET VALVE

E) DOWNSTREAM SHUT-OFF VALVE

D) AIR INLET VALVE

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND

MAINTENANCE REPORT SHALL INCLUDE ALL OF THE FOLLOWING

INFORMATION EXCEPT THE: - A) ADDRESS OF THE INSTALLATION

B) SERIAL NUMBER OF THE ASSEMBLY

C) TEST RESULTS OF CHECK VALVE NUMBER ONE (1)

D) TEST RESULTS OF CHECK VALVE NUMBER TWO (2)

E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING

E) DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING

THE BY-PASS LINE OF AN APPROVED BACKFLOW PREVENTION

ASSEMBLY MUST CONTAIN AN APPROVED ASSEMBLY OF EQUAL: - A)

CORROSION RESISTANCE

B) FLOW CAPACITY

C) PROTECTION

D) SIZE

E) TEMPERATURE RATING

C) PROTECTION

AN ATMOSPHERIC TYPE VACUUM BREAKER SHALL NOT BE SUBJECTED

TO WATER PRESSURE FOR PERIODS THAN ______ HOURS. - A) SIX (6)

B) EIGHT (8)

C) TWELVE (12)

D) TWENTY-FOUR (24)

E) NONE OF THE ABOVE

C) TWELVE (12)

IT IS POSSIBLE FOR A PERFECT VACUUM AT SEA LEVEL TO RAISE WATER

IN A PIPE APPROXIMATELY _________ FEET. - A) TWENTY-FIVE (25)

B) THIRTY (30)

C) THIRTY-TWO (32)

D) THIRTY-FOUR (34)

E) THIRTY-SIX (36)

D) THIRTY-FOUR (34)

WHAT IS THE MOST DESIRABLE PLACE TO INSTALL A BACKFLOW

PREVENTION DEVICE AND/OR ASSEMBLY? - A) IN A REINFORCED

CONCRETE PIT

B) IN AN ACCESSIBLE LOCATION ABOVE GROUND

C) UNDERGROUND, WITH A MINIMUM OF TWELVE (12) INCHES OF

COVER

D) AT OR ABOVE CEILING HEIGHT, TO PROTECT IT FROM VANDALISM

E) BEHIND THE BOILER OR EQUIPMENT SERVED, SO IT CAN BE WORKED

ON WHEN THE EQUIPMENT IS REMOVED

B) IN AN ACCESSIBLE LOCATION ABOVE GROUND