Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

BECC TEST 6 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | UPDATED 2024, Exams of Advanced Education

BECC TEST 6 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | UPDATED 2024 Required procedures for safe fuel system operation - Correct Answer-Contains all required procedures for the fuel system's safe operation Service tanks - Correct Answer-Tanks that hold enough purified fuel for steady flow Navy's preferred fuel oil - Correct Answer-F-76, for shipboard power plants Maximum fill level of fuel storage tanks - Correct Answer-95% during replenishment at sea Expansion tank - Correct Answer-Prevents fuel in storage tanks from spilling Emergency cut out valve - Correct Answer-Stops fuel flow in an emergency Acceptable fuel substitute for F-76 - Correct Answer-JP-5 Gauge measuring tape on a reel - Correct Answer-Sounding tape with swivel snap and brass plumb bob Free water detector contamination range - Correct Answer-Reliably detects 0-20 PPM Indication of contamination by highly volatile product - Correct Answer-Flashpoin

Typology: Exams

2023/2024

Available from 07/16/2024

professoraxel
professoraxel 🇺🇸

3.7

(26)

9.1K documents

1 / 4

Toggle sidebar

Related documents


Partial preview of the text

Download BECC TEST 6 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | UPDATED 2024 and more Exams Advanced Education in PDF only on Docsity! BECC TEST 6 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | UPDATED 2024 Required procedures for safe fuel system operation - Correct Answer-Contains all required procedures for the fuel system's safe operation Service tanks - Correct Answer-Tanks that hold enough purified fuel for steady flow Navy's preferred fuel oil - Correct Answer-F-76, for shipboard power plants Maximum fill level of fuel storage tanks - Correct Answer-95% during replenishment at sea Expansion tank - Correct Answer-Prevents fuel in storage tanks from spilling Emergency cut out valve - Correct Answer-Stops fuel flow in an emergency Acceptable fuel substitute for F-76 - Correct Answer-JP-5 Gauge measuring tape on a reel - Correct Answer-Sounding tape with swivel snap and brass plumb bob Free water detector contamination range - Correct Answer-Reliably detects 0-20 PPM Indication of contamination by highly volatile product - Correct Answer-Flashpoint of fuel Minimum flashpoint for F-76 and JP-5 fuels - Correct Answer-140 degrees Lowest temperature fuel ignites without spark or flame - Correct Answer-Autoignition temperature (AIT) Overboard oil spill response kit - Correct Answer-Used for spills and contains sorbent sweeps GFE Gas Free Engineer - Correct Answer-Ensures confined spaces are safe for entry Biggest hazard with shipboard fuels - Correct Answer-Fire or explosions Water indicating paste - Correct Answer-Changes color to indicate water depth in tank Absence of visible suspended water in sample - Correct Answer-Bright (term) Washing or cleaning fuel-soaked clothing - Correct Answer-ASAP Bypass valve - Correct Answer-Allows fuel to be routed to purifier without heating Fuel stripping system - Correct Answer-Removes water and sediment from fuel tanks Fuel oil self-cleaning purifier rating - Correct Answer-1800 RPM Re-purified fuel destination after purification - Correct Answer-Return to the same service tanks Function of spray shields - Correct Answer-Blocks potential spray of fuel Storage of hazardous material by Work Center - Correct Answer-Properly labeled container Document with status update of fuel and water supplies - Correct Answer-Fuel and water report Final disposal process for fuel-contaminated waste - Correct Answer-Record the disposal Rigorous periodic examination of an area - Correct Answer-Zone inspection Test to detect unintended open valves - Correct Answer-Integrity test Procedure for system alignments - Correct Answer-EOSS (Engineering Operational Sequencing System) Energizing a misaligned system - Correct Answer-Operator error Planning and scheduling a zone inspection - Correct Answer-PMS annual check Separation of intermixed water and oils - Correct Answer-OWS oil water separator Standardized document with material information - Correct Answer-SDS safety data sheet Completion of daily Fuel and Water Report - Correct Answer-Oil King Sequence of combustion events in engine cylinder - Correct Answer-Cycles Number of strokes in a four-stroke diesel engine - Correct Answer-Four Number of revolutions per cycle in a four-stroke diesel engine - Correct Answer-Two