Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024), Exams of Nursing

A wide range of topics related to horizontal cabling, cable installation, testing, and certification for the bicsi in225 7.0, installer 2 exam. It provides detailed information on the purpose of horizontal cabling, the minimum number of cables to be installed, cable color coding, cable length recommendations, and the proper handling and installation techniques to ensure compliance with industry standards and best practices. The document also covers topics such as safety equipment, firestopping, specialty systems, distributed antenna systems, and various communication standards and organizations. By studying this document, students can gain a comprehensive understanding of the knowledge and skills required to successfully install, test, and certify structured cabling systems, preparing them for the bicsi in225 7.0, installer 2 exam and their future career in the information and communication technology (ict) industry.

Typology: Exams

2023/2024

Available from 08/04/2024

Allivia
Allivia 🇺🇸

3.6

(70)

3.7K documents

1 / 69

Toggle sidebar

Related documents


Partial preview of the text

Download BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) and more Exams Nursing in PDF only on Docsity! BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The Decrease in magnitude or power loss of a signal. - Correct Answer ✅Attenuation Unit of measurement for attenuation. - Correct Answer ✅Decibels, dB The numerical system for designating wire diameter. - Correct Answer ✅American Wire Gauge (AWG) American Wire Gauge numbers have this relationship to the wire size. - Correct Answer ✅inverse relationship Type of wiring in which 2 conductors of a single circuit are twisted together in order to minimize EMI - Correct Answer ✅Balanced Twisted-Pair The formula relation between Voltage, impedance, and resistance. - Correct Answer ✅V=I*R BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Measured in Farads, causes a voltage difference between two wires when they are separated by insulation - Correct Answer ✅Capacitance Connector's ability to survive hundreds of insertions and withdrawls - Correct Answer ✅Durability Combined effects of resistance, inductive reactance, and capacitive reactance of a circuit. (Z) - Correct Answer ✅Impedance The two types of Balanced Twisted Pair cable - Correct Answer ✅STP (shielded) and UTP (Unshielded) Nominal characteristic impedance of balanced Twisted-pair cables - Correct Answer ✅100 Ohms at 100 MHz Cat 5e UTP has transmission characteristics up to: - Correct Answer ✅100 MHz BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This ANSI/TIA standard contains administrative information, such as labeling requirements and recommendations for the components of a structured cabling system - Correct Answer ✅ANSI/TIA-606 This ANSI/TIA standard provides recommendations and requirements related to Bonding and Grounding - Correct Answer ✅ANSI/TIA-607 This level of Backbone cabling is between the MC and the IC - Correct Answer ✅First Level Backbone This level of Backbone cabling is between the MC and the HC or IC - Correct Answer ✅First Level Backbone This level of Backbone cabling is between the IC and the HC - Correct Answer ✅Second Level Backbone BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This is the purpose of horizontal Cabling - Correct Answer ✅To distribute signal from the Horizontal Cross-connect in the TR to the work area This is the minimum number of cables to be installed/ran to each work area - Correct Answer ✅2 Cables This color is used to denote a cable demarcation point - Correct Answer ✅Orange This color is used to denote Network connections - Correct Answer ✅Green This color is used to denote Common Equipment - Correct Answer ✅Purple This color is used to denote first-level backbone cabling - Correct Answer ✅White BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This color is used to denote second-level backbone cabling - Correct Answer ✅Gray This color is used to denote Horizontal Cabling - Correct Answer ✅Blue This color is used to denote Inter-Building backbone cabling - Correct Answer ✅Brown This color is used to denote misc. systems, like alarm circuits - Correct Answer ✅Yellow This color is used to denote systems reserved for future used - Correct Answer ✅Red This is the maximum length of both equipment cords and patch cables - Correct Answer ✅5m (16.5ft) This type of cable is not recommended - Correct Answer ✅Undercarpet Cable BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) it's proper operational environment - Correct Answer ✅Computer Room This network type could consist of a very small, bluetooth network, used by a single person. - Correct Answer ✅PAN (Personal Area Network) This type of network could be in a single household - Correct Answer ✅LAN (Local Area Network) This type of network would include a single site with multiple buildings - Correct Answer ✅CAN (Campus Area Network) This type of network would cover an entire city - Correct Answer ✅MAN (Metropolitan Area Network) This type of network could cover a very large geographical area, such as the worldwideweb - Correct Answer ✅WAN (Wide Area Network) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This device manages one or more resources shared by workstation users and administrators on a network - Correct Answer ✅Server This is a network component that makes it possible to segment a network into multiple broadcast domains - Correct Answer ✅Router This is used to transform a standalone computer into a network station - Correct Answer ✅Network Software This device is equipped with features not commonly found on desktop computers - Correct Answer ✅Server This device is used to access a network - Correct Answer ✅Workstation This device is a combination of hardware and software - Correct Answer ✅Router BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This device segments an organizational network into multiple broadcast domains - Correct Answer ✅Router This device provides the user with the necessary interfaces for input and display - Correct Answer ✅Workstation This device provides network access and a centralized point for LAN communications - Correct Answer ✅Switch This device can manage multiple types of resources, or it can be dedicated to a single activity - Correct Answer ✅Server This device is affiliated with subnetworks/subnets - Correct Answer ✅Router This device provides dedicated network connection via a port - Correct Answer ✅Switch This type of station can be local or remote - Correct Answer ✅Workstation BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) What should you not wear when working near ICT circuits or equipment, and why? - Correct Answer ✅Metal jewelry or metal watchbands. They increase the risk of getting caught and they pose electrical hazards These are the four steps you should take when responding to an electrical fire - Correct Answer ✅RACE: Rescue, alarm, contain, extinguish This common item should be used to neutralize a battery Acid spill - Correct Answer ✅Baking Soda What are the Six actions you should take when you work indoors with a product that produces toxic or flammable vapors? - Correct Answer ✅Notify other workers Open Windows Restrict Airflow to other areas Blow toxic air directly outdoors- take care not to send into an office next door BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Blow fresh air into work area (ventilate) Take frequent breaks These measures can be used for identifying existing and potential work hazards - Correct Answer ✅Conduct baseline work surveys Analyze planned and new facilities Perform hazard analysis Conduct task risk assessments Conduct regular site safety inspections Provide a reliable system of problem notification Investigate accidents and incidents promptly Analyze trends over time to detect patterns If the layout of an ER is not provided, you should do this. - Correct Answer ✅Prepare one yourself and get it approved before beginning work BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) How many walls in a TR should have fire-retardent plywood installed on them? - Correct Answer ✅Minimum of 2 walls. Install around the Entire perimeter if possible. In a TR, Fire-retardant plywood should be this thick. - Correct Answer ✅3/4 of an inch The plywood installed in a TR should be what grade at a minimum? - Correct Answer ✅A/C, with the A-grade facing into the room. What Plywood grade has some blemishes and an occasional small knothole? - Correct Answer ✅C Grade You should install the plywood backboard this far Above the Finished Floor in a TR. - Correct Answer ✅8 in. AFF When installing plywood in a TR, if the edges do not align with the wall studs, you should attach it to the wall with: - Correct Answer ✅Toggle Bolts, 2in from the edges. BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This is the purpose of the AC grounding electrode system - Correct Answer ✅1. Establish a 0 volt reference for electrical systems 2. Provide a path for dissipation of currents from lighting or accidental contact with higher-voltage systems 3. Provide a path for the dissipation of electrostatic discharge (ESD) The purpose of an SBB - Correct Answer ✅Provide a bonding connection for telecommunication systems and equipment in the area served by a Telecommunications space The purpose of the TBC - Correct Answer ✅Bonds the electrical systems grounding electrode to the PBB This type of connection attaches the TEBC to the PBB/SBB - Correct Answer ✅Exothermic weld, direct crimp, or a two- hole lug (compression or exothermic type) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) When placing BBC(backbone bonding conductor) in multistory buildings, place them on these floors: - Correct Answer ✅Top floor and every third floor This is the recommended gauge for a BBC(backbone bonding conductor) - Correct Answer ✅6 AWG These are the problems that should be spotted with a visual inspection - Correct Answer ✅Loose Connections Corrosion Physical Damage System modifications This is the maximum allowable resistance between the grounding electrode and the PBB/SBBs - Correct Answer ✅0.1 Ohms (100 milliohms) A primary Protector is required when a circuit is exposed to: - Correct Answer ✅Electrical power faults and lightning BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) What is the recommended location for a Primary Protector to be installed in a circuit? - Correct Answer ✅Immediately adjacent to the exposed cable's point of entry Secondary Protectors are installed to protect against: - Correct Answer ✅Sneak Currents Grounding and Bonding specifications are found in this ANSI standard and these NEC articles - Correct Answer ✅ANSI/TIA-607 NEC articles 250 and 800 This is the preferred directional method for installing vertical backbone cable - Correct Answer ✅From top to bottom When securing a worksite before pulling cable, you should: - Correct Answer ✅Set up cones, signs, barricades and caution tape Place caution tape across the entrance of the work area to restrict access to unauthorized personnel BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) 4. Determine length and slack required 5. Use proper cable management hardware This cable termination configuration uses drain wires - Correct Answer ✅STP When terminating Cat3 cables, ensure the pair twist is maintained within ___ of the termination - Correct Answer ✅3 inches These are 3 tools that can be used to remove the cable sheath - Correct Answer ✅Ringing Tool Slitter tool Electrician's Snips This is the joining together of copper conductors or optical fibers from 2 or more cables at a point that is not considered a termination - Correct Answer ✅Splicing BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) These are 3 types of single splice connectors - Correct Answer ✅Full Pair, Straight Through splice connector Half-tap splice connector Butt splice connector These are 3 types of modular splice connectors - Correct Answer ✅Straight Module Bridge Module Half-Tap module When cables are assembled as 100-pair cable groups, these groups contain 4 units of 25 with these 4 binder colors - Correct Answer ✅Blue, Orange, Green, Brown These are two commonly used pieces of splicing equipment - Correct Answer ✅MS2 (modular splicing system) and 710 Splicing Rig In this type of splice, cables connect through in a line-by-line manner - Correct Answer ✅Straight Splice BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) In this type of splice, 3 or more cables enter the splice from any direction, with at least 1 of the cables entering and splitting into 2 or more when exiting - Correct Answer ✅Branch Splice In this type of splice, two or more cables enter from the same direction - Correct Answer ✅Butt Splice This type of splicing technique features a straight-across arrangement with little wire slack - Correct Answer ✅Inline Splicing This splicing method allows wire slack to be folded up into the splice. - Correct Answer ✅Foldback splicing method This type of modular splice connector joins the ends of binder groups from two cables - Correct Answer ✅Straight Module BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This copper tester piece of equipment is used to detect cable ends between outlets and patch panels - Correct Answer ✅Cable-End locator kit This copper tester has the ability to identify and locate cable defects, splices, connectors, and the location at which impedance changes occur. It can also be used to find the (electrical) length of a cable - Correct Answer ✅Time Domain Reflectometer (TDR) These are problems a Wire Map test can identify in a UTP/STP cable - Correct Answer ✅-Open circuits -Shorted Circuits -Polarity reversal -transposed pairs -split pairs -Drain Wire continuity (STP) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The permanent link test excludes these two things from the test - Correct Answer ✅The test Cable and the connection to the tester The Channel Link test includes ___ and excludes ___ - Correct Answer ✅Includes the customer's equipment cord(s) Excludes the connections to the tester on each end When doing a certification test for a permanent link, if a single parameter fails, the overall test result will be: - Correct Answer ✅FAIL In order to test the length/continuity of coaxial cable with a multimeter, you will need a ___ - Correct Answer ✅Shorting Plug What are the steps for troubleshooting? - Correct Answer ✅VIRT Verify, Isolate, Repair, Test BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The process of installing listed fire-rated materials into penetrations of fire-rated barriers in order to re-establish the barrier's fire rating - Correct Answer ✅Fire Stopping The ___ rating for firestop is the time period, expressed in hours, that it will resist flame passage - Correct Answer ✅F (Flame) Rating The ___ rating for firestop is the time it takes the non-fireside of the assembly to reach 180 degrees C (325 F) above the initial temperature (~400F total) - Correct Answer ✅T (Temperature) rating The ___ rating for firestop is the the amount of air leakage through the system, at both ambient temperatures and 400F, which simulates smoke leakage. - Correct Answer ✅L (leakage) rating The ___ rating for firestop determines if the barrier will be water tight when subjected to a 3ft column of water for 72 hours - Correct Answer ✅W (water) rating BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) 3. Core Bore Seals 4. Sleeve systems to firestop and smoke seal cables through a penetration 5. Cable trays In UL Fire-rated designations, what does the C stand for? - Correct Answer ✅Combination- can be used in floors and walls 4 differences between specialty systems compared to structured cabling systems are? - Correct Answer ✅1. Types of Topologies allowed 2. Cabling and termination practices 3. AHJ requirements 4. Use of industry standards A ___ is to specialty cabling what a consolidation point is to Voice and Data cabling - Correct Answer ✅Horizontal Connection Point (HCP) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) No more than ___ Horizontal Cabling Points (HCPs) should be placed in a single horizontal cabling link - Correct Answer ✅One HCP Maximum power output for Power over Ethernet (PoE) is - Correct Answer ✅15.4 Watts at 44 to 57 Volts What type of security system detects unauthorized entry into protected areas? - Correct Answer ✅Intrusion Detection System (IDS) This type of wireless system connects two locations together through Line-of-Sight (LOS) - Correct Answer ✅Point-to-point (P2P) This type of wireless network can send and receive data to other connected objects without an internet connection? - Correct Answer ✅Mesh Network (Meshnet) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This system retransmits and receives frequencies by means of antennas that are distributed throughout a building to provide even and usable coverage. - Correct Answer ✅Distributed Antenna System (DAS) These are the 4 primary components of a DAS - Correct Answer ✅Amplifiers Cabling Connectors Antennas A 6 dB increase in Antenna Gain will affect the antenna's range how? - Correct Answer ✅It will double the range These are the 4 antenna types - Correct Answer ✅1. Omnidirectional 2. Semi-directional 3. Directional 4. Radiating Cable BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) 2. Industry Standards 3. Building Codes and AHJ requirements 4. BICSI manuals 5. Manufacturer's specifications 6. ICT Fundamentals These drawings indicate the location of steel beams, concrete floors, and exterior walls - Correct Answer ✅Structural drawings: indicate the location of the components of the building structure itself These are tasks you should consider when performing a pre- construction site survey. - Correct Answer ✅1. Evaluate work environment considerations 2. Interface with the customer and contractors 3. Ascertain hours of operation and determine building access as needed 4. Verify building access and parking problems 5. Perform visual inspection of worksite BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) 6. Compare design docs with actual existing conditions These are activities to be performed while closing a project - Correct Answer ✅1. Reviewing and submitting test results; compliance with naming conventions 2. Review and submit as-built drawings 3. Review original SOW and punch item list 4. Finalize and submit O&M manual package 5. Performing final walk through w/ customer The practice of setting up temporary office spaces for personnel to relocate to in phases in order to continue working while their normal office space is retrofitted. - Correct Answer ✅Swing-space Phasing. The groups are swung from space to space as the spaces are phased into service. These are the colors associated with conductors in quad cable - Correct Answer ✅Green, Red, Black, Yellow BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Cross check ___ with phone cable records, as they are usually kept more current than cable records. - Correct Answer ✅Interoffice Telephone Directory These four testers can be used for Copper Cable Identification and tracing - Correct Answer ✅1. Tone Generator 2. Multimeter 3. Office Locator Kit 4. Certification Test set w/ Tone generator Type of documentation that contains existing cross-connect terminations and the changes that must be performed to execute the transition to the new system. Ensures a quality transition and expedites cutover. - Correct Answer ✅Cutsheet Type of cutover that involves transferring old system to new system in groups - Correct Answer ✅Phased Cutover BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) 1. Property of an electrical force field built around a conductor when current flows through it 2. The resistance to change in current - Correct Answer ✅Inductance Signal loss resulting from the insertion of a component link, or channel, between the transmitter and receiver - Correct Answer ✅Insertion Loss The coefficient used to determine the speed of transmission along a cable relative to the speed of light in a vacuum. Typically expressed as a percentage - Correct Answer ✅Nominal Velocity of Propagation (NVP) Unit of measurement of electrical resistance. Defined as the resistance that allows 1 ampere to flow when 1 volt is applied. - Correct Answer ✅Ohm. BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The measure of opposition a material offers to the flow of direct current (Ampere). - Correct Answer ✅Resistance (Ohms) A ration, expressed in dB, of the power of the outgoing signal to the power of the reflected signal. If the load's impedance does not match the characteristic impedance of the transmission line, some signal energy will be reflected back. - Correct Answer ✅Return Loss USOC acronym - Correct Answer ✅Universal Service Order Code 1 Hz is how many cycles per second? - Correct Answer ✅1 cycle per second 1 kilohertz (kHz) is how many cycles per second? - Correct Answer ✅1 million cycles per second BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Electrical noise in copper cabling, which can interfere with signal transmission - Correct Answer ✅Electromagnetic Interference (EMI) Ohm's Law formula - Correct Answer ✅voltage (v) = current (I) x resistance (R) Cat3 Cable operates at what frequency? - Correct Answer ✅16 MHz Cat 5e operates at what frequency? - Correct Answer ✅100 MHz Cat 6 operates at what frequency? - Correct Answer ✅250 MHz Cat 6a operates at what frequency? - Correct Answer ✅500 MHz BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) TIA stands for: - Correct Answer ✅Telecommunications Industry Association This is the order of the Hierarchy of Compliance - Correct Answer ✅1. AHJ 2. Codes and Regulations 3. Standards 4. Industry Best Practices 5. Manufacturer's Instructions The way We've always Done it! These are the six elements of professionalism according to the ITSIMM - Correct Answer ✅1. Credentials and ability to work 2. Personal image and ethos 3. Interpersonal Skills 4. On-Site activities 5. Remaining Current in your profession 6. Supporting your company and your colleagues BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) An installer should ___ others in public and ___ in private. - Correct Answer ✅Praise; Correct All communications should be: - Correct Answer ✅Timely Clear Concise Unbiased Truthful Free from unacceptable language Cabling Installation companies rely on these for new and repeat business. - Correct Answer ✅Customers What percentage of impact do Tone of voice, Body language, and words have on communication perceptions? - Correct Answer ✅Tone of Voice: 38% Body Language: 55% Words: 7% BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) This transmission method can only transmit signals in 1 direction - Correct Answer ✅Simplex 4 methods of minimizing adverse effects of EMI - Correct Answer ✅1. Use shielded cabling 2. Increase physical separation 3. Place in a shielded pathway 4. Use Fiber optic cabling instead of balanced twisted pair This formula will allow you to calculate apparent power in AC Circuits - Correct Answer ✅P = V*I The number of cycles a signal is repeated in a given amount of time is defined as: - Correct Answer ✅Frequency How many Sine waves are in 1 Hertz? - Correct Answer ✅1 Sine wave. 1:1 ratio BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) In a Multimode fiber optic cable, Chromatic dispersion occurs when ___. - Correct Answer ✅The light source that creates the light pulses does not furnish a perfectly monochromatic (single wavelength) light. These are the 3 components to a Fiber Optic Connector. - Correct Answer ✅1. Ferrule 2. Key 3. Latching Ring or mechanism These are the two ways to couple(connect) fiber optic cables - Correct Answer ✅Plug to Plug Plug to Jack This is an accepted collection of requirements and recommendations for the defining, construction, evaluation, application, or comparison of materials, equipment, products, and services - Correct Answer ✅Standards BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) These are the 4 types of Telecommunication spaces you would see within a building - Correct Answer ✅EF (Entrance Facility) ER (Equipment Room) TR (Telecommunication Room) TE (Telecommunication Enclosure) This Telecommunications space generally houses the equipment that serves an entire build, campus, or customer - Correct Answer ✅ER (Equipment Room) These are the 2 common depths for telecommunication racks - Correct Answer ✅100 mm (4 in) 150 mm (6 in) This is the purpose of telecommunications Pathways. - Correct Answer ✅To permit placement the placement of backbone and horizontal cables that support the structured cabling system (SCS) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Flexible metallic conduit (is/isn't) recommended because it: - Correct Answer ✅Isn't recommended; It creeps, shifts, causes damage to cables This type of conduit has thin walls and uses fittings that are threaded onto it - Correct Answer ✅Intermediate metal conduit (IMC) A ___conduit terminates in a vertical orientation - Correct Answer ✅Stub-Up Conduit A ___conduit terminates in a horizontal orientation - Correct Answer ✅Stub-Out conduit How many backbone levels are allowed in a Structured Cabling System? - Correct Answer ✅2 This is the maximum length for a horizontal balanced twisted- pair cable - Correct Answer ✅90 m (295 ft) BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The main purpose of a PBB is ___. - Correct Answer ✅To serve as the dedicated extension of the building's AC grounding electrode system for the Telecommunications Bonding Infrastructure This is the preferred method for attaching loose-tube optical fiber cables to a pull rope. - Correct Answer ✅Place the Fiber optic cables in a multi-weave wire mesh grip of the appropriate size that has a swivel pulling eye. What is the recommended method of terminating balanced twisted pair cable? - Correct Answer ✅IDC (insulation displacement contact) What pair-counts are 110 hardware frames available in? - Correct Answer ✅50-pair 100-pair 300-pair 900-pair BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) What pair-counts are BIX hardware frames available in? - Correct Answer ✅50-pair 250-pair 300-pair 900-pair The Three phases of testing are: - Correct Answer ✅1. Specification and Visual Verification 2. Testing with various test equipment 3. Documentation When firestopping, you should ___ products that are not a part of the listed assembly - Correct Answer ✅Not Substitute ANSI/TIA standard for Commercial Building Telecommunications Infrastructure Standard. Performance standards for SCS in commercial buildings - Correct Answer ✅ANSI/TIA 568.1 BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) ANSI/TIA: Balanced Twisted Pair Cabling and Components Standard - Correct Answer ✅ANSI/TIA 568.2 ANSI/TIA: Broadband Coaxial Cabling and Components Standard - Correct Answer ✅ANSI/TIA 586.4 ANSI/TIA: Optical Fiber Cabling and Components Standard - Correct Answer ✅ANSI/TIA 586.3 ANSI/TIA: Telecommunications Pathways and Spaces - Correct Answer ✅ANSI/TIA 569 ANSI/TIA: Residential Telecommunications Infrastructure Standard - Correct Answer ✅ANSI/TIA 570 ANSI/TIA: Administration Standards for Telecommunications Infrastructure - Correct Answer ✅ANSI/TIA 606 BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) The operator of any service that furnishes telecommunication transmissions delivered over access provider facilities. - Correct Answer ✅Service Provider (SP) This telecommunications space differs from other spaces in that it is generally considered a floor-serving space that provides the connection point between Backbone and Horizontal cabling. - Correct Answer ✅Telecommunications Room (TR) This is an internetworking device that operates at Layer 3 of the OSI model. It directs datagrams from one network to another. - Correct Answer ✅Router A voice communications device that establishes and terminates calls. Also a device designed to close, open, or close and open 1 or more electrical circuits - Correct Answer ✅Switch Section 1 of the SDS. It identifies the chemical and its uses - Correct Answer ✅Identification BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) Section 2 of the SDS. Identifies hazards and provides warnings for those hazards - Correct Answer ✅Hazard Identification Section 3 of the SDS. Lists ingredients, substances, mixtures, and trade secret information. - Correct Answer ✅Composition/Information on Ingredients Section 4 of the SDS. Describes initial care that should be given by untrained responders to an individual who has been exposed to the chemical - Correct Answer ✅First Aid Measures Section 5 of the SDS. Provides recommendations for fighting a fire caused by the chemical - Correct Answer ✅Fire Fighting Measures Section 6 of the SDS. Recommendations on the appropriate response to spills, leaks, or releases; this includes BICSI IN225 7.0, Installer 2, Exam Questions and Answers (Latest Update 2024) containment, clean up, and how to minimize exposure - Correct Answer ✅Accidental Release Measures Section 7 of the SDS. Provides guidance on the safe handling practices and conditions for safe storage - Correct Answer ✅Handling and storage Section 8 of the SDS. Indicates exposure limits, engineering controls, and PP measures to minimize worker exposure - Correct Answer ✅Exposure Controls/Personal Protection Section 9 of the SDS. Identifies physical and chemical properties of the substance or mixture - Correct Answer ✅physical and chemical properties Section 10 of the SDS. Describes reactivity hazards of the chemical and chemical stability information - Correct Answer ✅Stability and Reactivity