Download BICSI TECHNICIAN EXAM-With 100% verified solutions 2024-2025-tutor verified.docx and more Exams Advanced Education in PDF only on Docsity! BICSI TECHNICIAN EXAM-With 100% verified solutions 2024-2025-tutor verified L Rating A firestops ability to provide a smoke stop. (air leakage rate) To avoid damaging cable jacket, how often must you securely fasten electrical nonmetallic tubing (ENT) 3 Feet so it does not damage the cable What is the minimum dedicated power requirement of a telecommunications enclosure 120 V ac/20 The clearance behind the PBB when mounted, should be no less than- 2inch clearance behind the PBB when mounted When installing a plywood backboard, you should use galvanized screws that are a minimum of ______ longer than the depth of the wall covering, including the plywood 0.5in The use of under carpet telecommunications cable should be limited to: The interconnection point between horizontal cabling and UTC is a transition point (TP) Two 90-degree bends are allowed in any one conduit segment. A third bend may be acceptable under certain situations Runs under 33 feet When installing racks and cabinets on an access floor, what should they be secured to? The frame When placing cabinets on an access floor, how should the cabinets be aligned? One edge flush with the floor tile cut line What is a telecommunications enclosure TE used for? May be used to provide a suitable option for moves, adds, and changes without compromising infection control measures and other restrictions What size threaded rod would you typically use in a heavy duty ladder rack installation? 5/8in A supplemental bonding network within an ER or data center consisting of a set of conductors formed into a grid is often associated with what? Access flooring Which type of anchor requires a hole to be drilled into the floor where the attachment is to be made? Expansion anchors Min seperation from electric motors and transformers? 48" During which phase of the project would you determine cable labeling requirements? Communications Systems The IEEE 802.11 standard covers what material? Wi-Fi---> WLAN What is semi-directional? 180-degree pattern ANSI/TIA STANDARD: Balanced twisted-pair cable ANSI/TIA 568.2 ANSI/TIA STANDARD: Generic telecommunications cabling ANSI/TIA 568.0 ANSI/TIA STANDARD: Structured cabling systems in commercial buildings ANSI/TIA 568.1 ANSI/TIA STANDARD: Broadband Coaxial Cable ANSI/TIA 568.4 ANSI/TIA STANDARD: Optical Fiber Cable ANSI/TIA 568.3 Pathways and spaces 569 Administration and labeling 606 Bonding and grounding 607 Outside Plant (OSP) cabling 758 Residential 570 Data Centers 942 Class 1 Single building with one equipment room Class 2 Single building with multiple telecom spaces Class 3 Multiple buildings on a single campus Class 4 Multiple sites with multiple buildings Labels Consist of face stock material Tags Attached to the mounting surface