Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

BPI MULTIFAMILY BUILDING ANALYST - FIELD EXAM PRACTICE (MULTI-CHOICE), Exams of Organization and Business Administration

BPI MULTIFAMILY BUILDING ANALYST - FIELD EXAM PRACTICE (MULTI-CHOICE) WITH 100% DETAILED CORRECT ANSWERS 2025/2026 STUDY SET

Typology: Exams

2024/2025

Available from 05/02/2025

SUPERIORSCORES
SUPERIORSCORES 🇺🇸

3.6

(17)

7.5K documents

1 / 17

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
BPI MULTIFAMILY BUILDING
ANALYST - FIELD EXAM
PRACTICE (MULTI-CHOICE)
WITH 100% DETAILED
CORRECT ANSWERS
2025/2026 STUDY SET
WHAT WOULD LEAD YOU TO BELIEVE THIS COLD FLAT ROOF MAY CONTAIN INSULATION?
WHAT WOULD LEAD YOU TO BELIEVE THIS COLD FLAT ROOF MAY CONTAIN INSULATION?
A. THERE ARE SKYLIGHTS ON THE ROOF DECK
B. THERE ARE AIR VENTS PROTRUDING FROM THE ROOF DECK
C. IT IS A RIBBED METAL ROOF
D.THE ROOF IS LOCATED IN A SUNNY CLIMATE ZONE
USE A RIGID INSULATION AND THE ROOF COATING GOES NOT TOP OF THE INSULATION
WHAT IS THE BEST WAY TO INSULATE A FLAT ROOF WITHOUT AN AIR CAVITY OR ATTIC
SPACE?
A. BLOWING IN CELLULOSE INSULATION
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download BPI MULTIFAMILY BUILDING ANALYST - FIELD EXAM PRACTICE (MULTI-CHOICE) and more Exams Organization and Business Administration in PDF only on Docsity!

BPI MULTIFAMILY BUILDING

ANALYST - FIELD EXAM

PRACTICE (MULTI-CHOICE)

WITH 100% DETAILED

CORRECT ANSWERS

2025/2026 STUDY SET

WHAT WOULD LEAD YOU TO BELIEVE THIS COLD FLAT ROOF MAY CONTAIN INSULATION?

WHAT WOULD LEAD YOU TO BELIEVE THIS COLD FLAT ROOF MAY CONTAIN INSULATION?

A. THERE ARE SKYLIGHTS ON THE ROOF DECK

B. THERE ARE AIR VENTS PROTRUDING FROM THE ROOF DECK

C. IT IS A RIBBED METAL ROOF

D.THE ROOF IS LOCATED IN A SUNNY CLIMATE ZONE

USE A RIGID INSULATION AND THE ROOF COATING GOES NOT TOP OF THE INSULATION

WHAT IS THE BEST WAY TO INSULATE A FLAT ROOF WITHOUT AN AIR CAVITY OR ATTIC

SPACE?

A. BLOWING IN CELLULOSE INSULATION

B. BLOWING IN FIBERGLASS INSULATION

C. USE A RIGID INSULATION AND THE ROOF COATING GOES NOT TOP OF THE INSULATION

D. FLAT ROOFS CAN'T BE INSULATED

ATMOSPHERIC VENTING

WHAT TYPE OF VENTING IS USED FOR THIS WATER HEATER?

A. ATMOSPHERIC VENTING

B. POWER VENTING

C. DIRECT VENTING

D. INDIRECT VENTING

POWER VENTING

WHAT TYPE OF VENTING IS USED FOR THIS WATER HEATER?

A. ATMOSPHERIC VENTING

B. POWER VENTING

C. DIRECT VENTING

D. INDIRECT VENTING

C. NOT ENOUGH INFORMATION

D. IT IS A TWO PIPE STEAM SYSTEM

IT IS A TWO PIPE STEAM SYSTEM

WHAT TYPE OF HEATING SYSTEM IS SHOWN?

A. IT IS A ONE PIPE STEAM SYSTEM SHOWN BY THE SUPPLY PIPE ON THE RIGHT AND AIR

VENT ON THE LEFT

B. IT IS A TWO PIPE HOT WATER SYSTEM

C. NOT ENOUGH INFORMATION

D. IT IS A TWO PIPE STEAM SYSTEM

IT HELPS TO MOVE THE CONDENSATE BACK TO THE BOILER

THE FUNCTION OF CONDENSATE PUMP AND AIR VENT ON A STEAM SYSTEM IS:

A. IT HELPS TO MOVE THE CONDENSATE BACK TO THE BOILER

B. IT KEEPS THE STEAM SYSTEM FROM EXPLODING

C. IT KEEPS THE STEAM AT A HIGHER TEMPERATURE

NATURAL GAS

THE PAINTED YELLOW PIPE TELL US THAT THE FUEL SOURCE FOR THIS COMMERCIAL

BOILER IS:

A. #2 FUEL OIL

B. ELECTRIC

C. JET FUEL

D. NATURAL GAS

BELT DRIVEN

WHAT TYPE OF EXHAUST FAN IS PICTURED?

A. DIRECT DRIVE

B. BELT DRIVEN

C. GRAVITY DRIVEN

D. NATURAL GAS POWERED

THERMOSTATIC RADIATOR VALVE

THE ENERGY SAVING DEVICE IN THIS PICTURE IS A:

A. OPERATING PRESSURETROL

B. AQUASTAT

C. THERMOSTATIC RADIATOR VALVE

D. AIR RELIEF VALVE

A. TURN UP THE BLOWER ON THE AIR HANDLER

B. CHECK THE MERV RATING ON THE FURNACE FILTER

C. BALANCE SUPPLY AND RETURN AIRFLOW

D. VACUUM THE SUPPLY GRATE AND VERIFY THE GRATE IS OPEN

VERIFY WIRING IS NO LONGER BEING USED OR UPGRADE WIRING TO LOCAL CODE

WHAT WOULD BE THE APPROPRIATE ACTION FOR PROCEEDING WITH AN ENERGY

IMPROVEMENT MEASURE IN THIS ATTIC?

A. USE BLOWN IN CELLULOSE INSTEAD OF CHOPPED FIBERGLASS INSULATION

B. AIR SEAL THE ATTIC FLOOR

C. VERIFY WIRING IS NO LONGER BEING USED OR UPGRADE WIRING TO LOCAL CODE

D. USE BLOWN IN CHOPPED FIBERGLASS INSTEAD OF CELLULOSE INSULATION

GAS LEAKS

THIS INDIVIDUAL IS TESTING FOR:

A. WATER LEAKS

B. WATER TEMPERATURE

C. GAS LEAKS

D. REFRIGERANT LEAKS

MANUAL RESET

THIS IS A ______________ PRESSURETROL.

A. MODULATING

B. MANUAL RESET

C. OPERATING

D. STANDARD

MODULATING

THIS IS A _____________ PRESSURETROL.

A. MODULATING

B. MANUAL RESET

C. OPERATING

D. STANDARD

OPERATING

THIS IS A ____________ PRESSURETROL.

NOT ENOUGH INFORMATION

WHICH YEAR HAD A HIGHER NUMBER OF HEATING DEGREE DAYS?

A. 2013

B. 2014

C. NOT ENOUGH INFORMATION

ERV OR HRV

THE ENERGY SAVING DEVICE IN THIS PICTURE IS A:

A. OPERATING PRESSURETROL

B. BOILER DIAPHRAGM

C. ERV OR HRV

D. COMMERCIAL EXHAUST FAN

DIRECT METERED FOR ELECTRICITY

THIS METER BANK SHOWS THAT THE BUILDING IS:

A. MASTER METERED WITH SUB-METER BOXES INSTALLED

B. DIRECT METERED FOR NATURAL GAS

C. MASTER METERED FOR ELECTRICITY

D. DIRECT METERED FOR ELECTRICITY

SUPPLY REGISTER FLOW AND/OR EXHAUST FAN FLOW

WHAT IS THIS DEVICE USED TO MEASURE:

A. SUPPLY REGISTER FLOW AND/OR EXHAUST FAN FLOW

B. LEAKS IN THE EXHAUST FAN

C. CSI IN THE EXHAUST FAN

D. LUMEN OUTPUT FROM THE EXHAUST FAN LIGHT

57 CFM

USING AN ANEMOMETER, READINGS SHOWN ON THE CHART TO THE RIGHT WERE TAKEN

OVER A FAN THAT MEASURES 2' X 2'. WHAT IS THE CFM FLOW FOR THAT EXHAUST FAN?

A. 57 CFM

B. 213 CFM

C. 106 CFM

D. 26 CFM

WINDOW LINTEL (A BEAM THAT IS USUALLY PLACED ABOVE WINDOWS)

ON THE NORTH SIDE OF THE BUILDING LOCATED OFF THE WALL

THE BEST LOCATION ON A BUILDING FOR A TEMPERATURE SENSOR TO BE INSTALLED IS?

A. ON THE NORTH SIDE OF THE BUILDING LOCATED OFF THE WALL

B. ON THE SOUTH SIDE OF THE BUILDING

C. ON THE EAST SIDE OF THE BUILDING LOCATED OFF THE WALL

D. ON THE WEST SIDE OF THE BUILDING

10PM, 5AM, 10AM

THE TIMER IN THIS PICTURE WILL NEXT TURN OFF AT ____________. THEN TURN ON AT

________. THEN OFF AGAIN AT ______________.

A. 10PM, 5AM, 10AM

B. 10AM, 5PM, 10PM

C. 10PM, 5AM, 10PM

D. NOT ENOUGH INFORMATION

THE DOOR MAY BE PROPERLY WEATHER-STRIPPED AND SWEEP ADDED

WHAT OPPORTUNITY FOR EFFICIENCY IMPROVEMENTS MAY BE AVAILABLE IN THIS

SITUATION AS SHOWN:

A. THE DOOR MAY BE PAINTED

B. THE DOOR MAY BE PROPERLY WEATHER-STRIPPED AND SWEEP ADDED

C. A DOUBLE DOOR MAY BE INSTALLED INSTEAD

D. A SHORTER DOOR COULD BE INSTALLED

AIR ELIMINATOR TANK

THE TANK IS CALLED A:

A. STEAM ELIMINATOR TANK

B. AIR ELIMINATOR TANK

C. PRESSURE REGULATOR TANK

D. CONDENSATE PUMP

INSTALL A DAYLIGHT SENSOR

WHAT LIGHTING EFFICIENCY IMPROVEMENT CAN BE MADE TO THIS SCENARIO?

A. INSTALL A DAYLIGHT SENSOR

B. INSTALL A MOTION SENSOR

C. WATER PUMP

D. WATER MOTOR

MECHANICAL MIXING VALVE

THIS PICTURE SHOWS A:

A. PRESSURE RELIEF VALVE

B. ELECTRIC MIXING VALVE

C. MECHANICAL MIXING VALVE

D. AQUASTAT

UL RATING 776N

WHAT INFORMATION IS NOT AS IMPORTANT IN, REGARDS TO ENERGY EFFICIENCY, ON

THIS LABEL?

A. MFG DATE NOV 86

B. MODEL NO.

C. UL RATING 776N

D. 110 VOLTS, 60 CYCLE 1 PHASE, 7.0 AMPS

WHAT IS THE R VALUE RATING FOR THIS WINDOW?

A..

B. 3.

C..

D. 1.

MAINTAINS SUPERHEAT IN THE REFRIGERANT LEAVING THE EVAPORATOR COIL

WHAT DOES THE PICTURED COMPONENT DO ON AN AC SYSTEM?

A. MAINTAINS SUBCOOLING IN THE REFRIGERANT LEAVING THE CONDENSER COIL

B. MAINTAINS SUBCOOLING IN THE REFRIGERANT LEAVING THE EVAPORATOR COIL

C. MAINTAINS SUPER HEAT IN THE REFRIGERANT LEAVING THE CONDENSER COIL

D. MAINTAINS SUPERHEAT IN THE REFRIGERANT LEAVING THE EVAPORATOR COIL