The CBET exam secrets study guide is a comprehensive resource for individuals preparing for the Certified Biomedical Equipment Technician (CBET) exam. It covers a wide range of topics related to biomedical equipment, including pulse oximeters, sterilizers, electroencephalography, steam sterilization, ultrasound, cardioversion, bilirubin treatment, IV pumps, ECG recordings, X-ray equipment, defibrillators, and more. The study guide provides detailed explanations and insights to help candidates understand and apply the concepts covered in the CBET exam.

Typology: Exams

2023/2024

Available from 08/23/2024

winnie-mumbi-1
winnie-mumbi-1 🇬🇧

2

(4)

233 documents

Partial preview of the text

Download CBET Exam Secrets Study Guide and more Exams Nursing in PDF only on Docsity! CBET Exam Secrets Study Guide 1. You have a reading on 2 different manufacturer's pulse oximeters. The nurse says they are reading wrong because there is a 2% difference in the blood oxygen levels between them. What is wrong? -         A.Both of them need to be re-calibrated B.Trust the one from a known manufacturer ***c. This is normal operation d. There is too much light from overhead affecting the readings. 2. A sterilizer has a jacket pressure of 30 psi and a chamber pressure of 28 psi. What is wrong with it? -         *****a. This is normal operation when a cycle is running). b. The chamber solenoid is defective c. The jacket solenoid is defective. d. The overpressure solenoid is defective 3. The EEG is used to detect: -         a. Murmurs b. Arrhythmias ***c. Brain Tumors d. Dermatitis 4. Steam Sterilization Temperatures are usually above -         a. 62 Degrees Celsius b. 102 Degrees Celsius ***c. 132 Degrees Celsius d. 162 Degrees Celsius 5. Ultrasoundisbestdescribedas: -         a. Radiation b. Flow of Sonic Particles c. Electromagnetic Waves ****d. Acoustic Compressions 6. During Synchronous Cardioversion -         a. *******The defibrillator is set to fire approx 20ms after the peak of the "R" wave b. The heart is in fibrillation c. The heart is sometimes in fibrillation d. The defibrillator is set to fire approx 20ms before the peak of the "R" wave 7. What is the Highest Temp that an infant warmer should be before the alarm is tripped. -         a. 37 degrees Celsius b. *****39 degrees Celsius c. 43 degrees Celsius d. 50 degrees Celsius 8. The treatment of high bilirubin in babies is treated by; -         a. Blood Transfusion b. Drug Therapy c. Bile Duct surgery d. *******Light Therapy 9. Ultrasound Energy for imaging is produced by; -         a. ******Piezoelectric Crystal b. Charging Amp c. Feedback oscillator d. Doppler effect 10.What is the most life-threatening problem associated with an IV Pump? -         a. *****Air Embolism b. Free uncontrolled flow to the patient c. Occlusion to patient d. Vein closing when infusion is complete 11. A paper speed of 25mm/sec is set on an ECG recorder. The patient's heart rate is 60 beats per minute. In a normal ECG waveform, how often will the R wave show up on the paper? -         a. Ever 25 cm b. Every 3 big boxes on the paper c. ******Ever 5 big boxes on the paper d. Ever 20 mm on paper fed 12. Using your test equipment you feed a 1milli volt signal into ECG leads. You have the monitor set to read on lead 2. You are using a 3 lead set. The monitor ECG size is set to 1 milli volt. You run a strip on the recorder. What should you see for amplitude on the recording? -         a. One small square on the paper positive deflection b. One big square on the paper positive deflection c. Two small squares on the paper positive deflection d. ****Two big squares on the paper positive deflection 13. What selection on an electro surgical unit most resembles a sine wave? -         a. ****Pure cut b. Coag c. Blend 1 d. Bipolar coag 14. The purpose of a grid on an x-ray bucky is to: -         a. ****Stop scatter radiation from going to the film or detector b. Focus the x-ray beam c. Magnify the x-ray beam d. Add lines to the film for measurement purposes 15.The normal test load for a defibrillator is: -         a. 50 ohms b. 75 ohms c. 100 ohms d. ****50 ohms non-inductive 16.An ECG monitor acquires the respiration wave and rate from: -         a. ECG lead 1         A. ECG interference B. Out of calibration C. Low Battery D. ****Leaky cuff or hose (patient circuit) 33. What is the process that makes X rays dangerous -         A. Chelation B. Dehydration C. Scintillation D. ****Ionization 34. What is the most common temperature for an infant incubator? -         A. ***37 degrees Celsius B. 25 degrees Celsius C. 98.6 degrees Celsius D. 53 degrees Celsius 35. When checking an equipment storage area a BMET finds a sequential compression device with a broken tag and a question mark written on the tag. What is the most appropriate first step to take -         A. Ask the patient if the device is working correctly B. Remove the tag and return to service C. Change the air filter D. *****Verify proper operation 36. An IV line with a mechanical interlock is used for? -         A. Air in line B. Dose limiting errors C. ****Free flow D. Fluid depletion 37. A nurse reports that a surgical laser won't turn on. The nurse said it was working after the last case, but hasn't worked since the room was cleaned by housekeeping. The laser will not turn on when the switch is turned on. What is the most likely cause -         A. Filter is clogged with dust or lint B. Display brightness or contrast is too low C. Housekeeping unplugged and re-plugged laser D. ****Emergency stop is depressed 38. The primary use of an otoscope is for? -         A. Examining the eyes B. ***Examining the ears C. Examining the uterus D. Examining the heart 39. Clamping the IV tubing between the distal end and the pump would verify the operation of which alarm? - CBET Exam Secrets Study Guide 1. You have a reading on 2 different manufacturer's pulse oximeters. The nurse says they are reading wrong because there is a 2% difference in the blood oxygen levels between them. What is wrong? -         A.Both of them need to be re-calibrated B.Trust the one from a known manufacturer ***c. This is normal operation d. There is too much light from overhead affecting the readings. 2. A sterilizer has a jacket pressure of 30 psi and a chamber pressure of 28 psi. What is wrong with it? -         *****a. This is normal operation when a cycle is running). b. The chamber solenoid is defective c. The jacket solenoid is defective. d. The overpressure solenoid is defective 3. The EEG is used to detect: -         a. Murmurs b. Arrhythmias ***c. Brain Tumors d. Dermatitis 4. Steam Sterilization Temperatures are usually above -         a. 62 Degrees Celsius b. 102 Degrees Celsius ***c. 132 Degrees Celsius d. 162 Degrees Celsius 5. Ultrasoundisbestdescribedas: -         a. Radiation b. Flow of Sonic Particles c. Electromagnetic Waves ****d. Acoustic Compressions 6. During Synchronous Cardioversion -         a. *******The defibrillator is set to fire approx 20ms after the peak of the "R" wave b. The heart is in fibrillation c. The heart is sometimes in fibrillation d. The defibrillator is set to fire approx 20ms before the peak of the "R" wave 7. What is the Highest Temp that an infant warmer should be before the alarm is tripped. -         a. 37 degrees Celsius b. *****39 degrees Celsius c. 43 degrees Celsius d. 50 degrees Celsius 8. The treatment of high bilirubin in babies is treated by; -         a. Blood Transfusion b. Drug Therapy c. Bile Duct surgery d. *******Light Therapy 9. Ultrasound Energy for imaging is produced by; -         a. ******Piezoelectric Crystal b. Charging Amp c. Feedback oscillator d. Doppler effect 10.What is the most life-threatening problem associated with an IV Pump? -         a. *****Air Embolism b. Free uncontrolled flow to the patient c. Occlusion to patient d. Vein closing when infusion is complete 11. A paper speed of 25mm/sec is set on an ECG recorder. The patient's heart rate is 60 beats per minute. In a normal ECG waveform, how often will the R wave show up on the paper? -         a. Ever 25 cm b. Every 3 big boxes on the paper c. ******Ever 5 big boxes on the paper d. Ever 20 mm on paper fed 12. Using your test equipment you feed a 1milli volt signal into ECG leads. You have the monitor set to read on lead 2. You are using a 3 lead set. The monitor ECG size is set to 1 milli volt. You run a strip on the recorder. What should you see for amplitude on the recording? -         a. One small square on the paper positive deflection b. One big square on the paper positive deflection c. Two small squares on the paper positive deflection d. ****Two big squares on the paper positive deflection 13. What selection on an electro surgical unit most resembles a sine wave? -         a. ****Pure cut b. Coag c. Blend 1 d. Bipolar coag 14. The purpose of a grid on an x-ray bucky is to: -         a. ****Stop scatter radiation from going to the film or detector b. Focus the x-ray beam c. Magnify the x-ray beam d. Add lines to the film for measurement purposes 15.The normal test load for a defibrillator is: -         a. 50 ohms b. 75 ohms c. 100 ohms d. ****50 ohms non-inductive 16.An ECG monitor acquires the respiration wave and rate from: -         a. ECG lead 1         A. ECG interference B. Out of calibration C. Low Battery D. ****Leaky cuff or hose (patient circuit) 33. What is the process that makes X rays dangerous -         A. Chelation B. Dehydration C. Scintillation D. ****Ionization 34. What is the most common temperature for an infant incubator? -         A. ***37 degrees Celsius B. 25 degrees Celsius C. 98.6 degrees Celsius D. 53 degrees Celsius 35. When checking an equipment storage area a BMET finds a sequential compression device with a broken tag and a question mark written on the tag. What is the most appropriate first step to take -         A. Ask the patient if the device is working correctly B. Remove the tag and return to service C. Change the air filter D. *****Verify proper operation 36. An IV line with a mechanical interlock is used for? -         A. Air in line B. Dose limiting errors C. ****Free flow D. Fluid depletion 37. A nurse reports that a surgical laser won't turn on. The nurse said it was working after the last case, but hasn't worked since the room was cleaned by housekeeping. The laser will not turn on when the switch is turned on. What is the most likely cause -         A. Filter is clogged with dust or lint B. Display brightness or contrast is too low C. Housekeeping unplugged and re-plugged laser D. ****Emergency stop is depressed 38. The primary use of an otoscope is for? -         A. Examining the eyes B. ***Examining the ears C. Examining the uterus D. Examining the heart 39. Clamping the IV tubing between the distal end and the pump would verify the operation of which alarm? -         A. Air in line B. KVO (Keep Vein Open) C. Free Flow D. ****Downstream occlusion 40. If a PCA pump delivers when not asked to by the patient. What is the most likely cause? -         A. Device is operating on battery power B. Maximum dose is reached C. ***Faulty patient controller D. 60 Hz interference 41. Pitted defibrillator paddles could cause? -         A. ****Burns to the patient B. Unable to use cardio version mode C. No energy transferred to the patient for shock D. Unable to pick up ECG in paddle mode 42. Instruments used in laser cases should be -         A. Plastic B. Polished C. ***Anodized D. Gold 43. A strain gauge changing length will result in? -         A. Pressure of the gauge changing B. Stress of the gauge changing C. ****Resistance of the gauge changing D. Force of the gauge changing 44. During a laparoscopic procedure what gas is used in an insuflator to expand the working space for the doctor -         A. Oxygen B. Medical grade air C. ***Carbon dioxide D. Helium 45. A spirometer is used for measuring? -         A. ****Tidal volume B. inspiratory pressue C. Diastolic pressure D. Cardiac flow 46. An ophthalmoscope is used to exam? -         A. The ears B. ***The eyes C. Hearing loss D. Pressure of the eyes 47. Centrifugal force is affected by which two factors? -         A. Mass and weight B. ***Radius and rotation speed C. Rotor balance and radius D. Temperature and speed 48. What is most characteristic about a laser beam? -         A. ***Coherent B. Congruent C. Multichromatic D. Multideirectional 49. An IV pump has a drug that is .5mg/mL concentration. The pump is set to deliver a 10 mL bolus. After the bolus it is set to run at 10 mL.hr. After 4 hrs how much drug will be delivered -         A. 2.5 mg B. 5mg C. ****25 mg D. 50 mg 50. Einthoven's law states that ECG lead 1 and 3 are the equivalent to -         A. ***Lead 2 B. Lead 5 C. Lead AVL D. Lead AVR 51. A plasma sterilizer sterilizes by exciting -         A. Ethylene oxide B. Carbon dioxide C. Calcium carbonate dissolved in water D. *****Hydrogen peroxide 2. When taking a manual blood pressure the first Korotokoff sound is the -         A. Mean blood pressure B. ****Systolic pressure C. Diastolic pressure D. Central venous pressure 53. An ESU with a high crest factor waveform indicates the ability of the ESU to? -         A. Cut tissue B. ****Coagulate tissue C. Blend tissue D. Fulgurate tissue 54. What is middleware -