Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified), Exams of Nursing

CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified)/CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified)/CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified)

Typology: Exams

2023/2024

Available from 07/01/2024

Biodexpert
Biodexpert 🇺🇸

4

(32)

1K documents

1 / 24

Toggle sidebar

Related documents


Partial preview of the text

Download CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified) and more Exams Nursing in PDF only on Docsity! CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified) Ethylene Oxide gas kills microorganisms by a process called - ANSWER Alkylation What is the process where a chromium oxide layer is placed on a surgical instrument - ANSWER Passivation What are the dark black Craters on a stainless steel instrument called - ANSWER Pitting What is the enzyme that breaks down fatty deposits like bone marrow and adipose tissue? - ANSWER Lipase What lubricant is recommended for use on surgical instruments? - ANSWER Water- based What can be used to remove severe stains on stainless steel instruments? - ANSWER Organic Acid Detergent Frequently used items are stored on - ANSWER Middle shelf What is another name for Healthcare Acquired Infection? - ANSWER Nosocomial Infection What is the principle route of HAI's? - ANSWER Direct Contact What is the use of physical or chemical means to remove, inactivate, destroy pathogens on the surface of an item? - ANSWER Decontamination A sterile item should not be handled more than times. - ANSWER 4 Another name for the lowest amount of stock - ANSWER Reorder point In Sterile Storage area, the ventilation system must be under - ANSWER Positive pressure Influence is caused by a - ANSWER Virus Distal ends of rigid endoscopes should by cleaned with a - ANSWER Soft bristled brush Indicator (autoclave) tape is considered what type of CI? - ANSWER type 1 Indicators for a specific test like a Bowie-Dick test are what type of CI? - CBSPD Exam Prep Questions With 100% Correct Answers 2024(A+ Graded Verified) Ethylene Oxide gas kills microorganisms by a process called - ANSWER Alkylation What is the process where a chromium oxide layer is placed on a surgical instrument - ANSWER Passivation What are the dark black Craters on a stainless steel instrument called - ANSWER Pitting What is the enzyme that breaks down fatty deposits like bone marrow and adipose tissue? - ANSWER Lipase What lubricant is recommended for use on surgical instruments? - ANSWER Water- based What can be used to remove severe stains on stainless steel instruments? - ANSWER Organic Acid Detergent Frequently used items are stored on - ANSWER Middle shelf What is another name for Healthcare Acquired Infection? - ANSWER Nosocomial Infection What is the principle route of HAI's? - ANSWER Direct Contact What is the use of physical or chemical means to remove, inactivate, destroy pathogens on the surface of an item? - ANSWER Decontamination A sterile item should not be handled more than times. - ANSWER 4 Another name for the lowest amount of stock - ANSWER Reorder point In Sterile Storage area, the ventilation system must be under - ANSWER Positive pressure Influence is caused by a - ANSWER Virus Distal ends of rigid endoscopes should by cleaned with a - ANSWER Soft bristled brush Indicator (autoclave) tape is considered what type of CI? - ANSWER type 1 Indicators for a specific test like a Bowie-Dick test are what type of CI? - ANSWER Type 2 Single-Variable indicators like glass ampules are what type of CI? - ANSWER Type 3 What microbe can survive adverse conditions by forming spores? - ANSWER Clostridium What must be made available to distribution personnel - ANSWER Policies and procedures What distribution system is not considered a specialty cart? - ANSWER Exchange Barcoding is part of what system? - ANSWER Tracking MAX humidity in sterile storage area - ANSWER 70% Prevent biofilm is lumens by - ANSWER Rinse with critical water and dry well Sterile Processing should plan for what percent of total needs on units? - ANSWER 90% Stocks must be rotated to reduce - ANSWER Outdates What is recommended alongside a high-alkaline detergent in a mechanical washer? - ANSWER Neutralizing Acid OSHA requires transport containers for potentially infectious materials be - ANSWER Leak-proof Opened and unused sets should be - ANSWER Reprocessed Sterilizer's ability to sterilize under actual use conditions - ANSWER Maximum-Load testing Incoming saturated steam needs a dryness range of - ANSWER 97-100% How often are Floors and work surfaces cleaned? - ANSWER Daily What is needed before a medical device is cleaned/processed? - ANSWER IFU Effective sterilization begins with - ANSWER thorough cleaning Outcome of high alkaline H2O when cleaning instruments - ANSWER Corrosion What phase of sterilization does gradual heating of packs occur? - ANSWER Conditioning What distribution system requires the use of a predetermined list? - ANSWER Par-level Labor intensive distribution system that requires the department to be responsible for maintaining inventory levels - ANSWER Demand Critical devices require - ANSWER Sterilization between uses Vancomycin Resistant Enterococcus are gram positive cocci that survive on surfaces - ANSWER 6-7 days Vancomycin Resistant Enterococcus are gram positive cocci that survive on hands - ANSWER Hours rigid sterilization containers mUst be biologically tested before - ANSWER Purchase How often do drain line baskets in a non-table top steam sterilizer need to be cleaned ? - ANSWER daily critical parameters for heat sealing paper-plastic pouches - ANSWER Temperature, pressure, dwell time Instruments must NEVER be - ANSWER Engraved Damage to instruments are avoided by - ANSWER Avoiding temperature and humidity extremes Microbes resistant to heat and chemicals - ANSWER Capsulated bacterium Most efficient distribution system - ANSWER Total exchange cart First step when sterilizing an instrument - ANSWER Cleaning When sterilizing 2 large basins with smaller bowls in the same set, CI is placed - ANSWER Top and bottom of basins Barrier precautions, hand washing, and sharps precautions come under the umbrella of - ANSWER Standard precautions bluish-black stains - ANSWER reverse plating may occur; when two different types of metals are ultrasonically processed together(e.g. stainless steel and chrome processed together) Bluish-gray stains - ANSWER cold sterilization solution being used outside manufacturers guidelines Sterile Trays that may be subject to storage challenges should be - ANSWER Place in sterility maintenance cover Air exchange rate in sterile storage - ANSWER 4 Disadvantage of Exchange Cart System - ANSWER Duplicate bladder -crine - ANSWER secretion blephar/o - ANSWER eyelid stomato - ANSWER mouth Ileo - ANSWER small intestine frenu- - ANSWER fold -cele - ANSWER swelling hyster/o - ANSWER uterus Reno- - ANSWER kidney -atresia - ANSWER closure -malacia - ANSWER abnormal softening medical grade kraft paper can not be used with - ANSWER LTGP Waterless antiseptic contains what concentration of alcohol to be most effective? - ANSWER 60-90% Which detergent works best in mechanical washers due to lack of friction? - ANSWER Alkaline What cleaner is used to wash laparoscopies? - ANSWER Ultrasonic lumen cleaner Multi step process in washer to avoid corrosion - ANSWER Alkaline detergent, wash, acid rinse, regular rinse The ceiling threshold limit value for Glutaraldehyde is - ANSWER 0.05 ppm What type of clearance do rigid endoscopes require? - ANSWER FDA 510k How to avoid damage to items in receiving area? - ANSWER Remove from original cartons Sets intended for the days use are usually collected - ANSWER The day before they're used The largest customer of Central Service is: - ANSWER operating room What does a patient equipment processing area contain? - ANSWER Electric outlets, gloves, "clean" tags, clear bags for covering equipment The process performed by a manufacturer to ensure a product consistently yields results complying with predetermined specifications - ANSWER Validation Steam entering the sterilizer should have what percentage of entrained water? - ANSWER 3% To prevent biofilms in lumens: - ANSWER Use critical water and dry well What residue leaves bluish or rainbow-type stains on instruments - ANSWER Iron and silicates In table-top sterilizers, steam in generated from: - ANSWER Distilled/critical water poured in a reservoir in/on the machine Sterility type for reusable instruments processed within SPD - ANSWER Event related sterility Max weight when sterilizing 2 large basins with smaller bowls in the set - ANSWER 7lb Thickness of a sterility maintenance cover should be - ANSWER 2-3mils thick Excellent cleaning starts this process, disinfection continues this process, and sterilization eliminates bioburden. Proper performance of this task results in the scientific principle: - ANSWER Log reduction Spaulding Classification states non critical devices require - ANSWER Low level disinfection Equiptment is identified as nonfuctional on floor. The spd tech assigned to patient care should: - ANSWER Leave item "as is" and contact biomedical engineering Printouts and graphs that show sterilizer met proper parameters are examples of: - ANSWER Physical monitors/ mechanical indicators What property make mycobacteria hard to kill? - ANSWER Fatty protective sheath Medical grade kraft paper, moist instruments, implants, & long/narrow lumens can NEVER be used in this sterilizer: - ANSWER LTGP What factor is critical to EO gas killing microbes? - ANSWER Humidity Minimal amount of IFUs spd techs should haveand where: - ANSWER 2, one at decontamination and the other at prep and packaging AMII Tir 34 establishes parameters and values for testing: - ANSWER Water quality Pathogens prefer these environmental conditions: - ANSWER Warm, dark and moist Visualize entire large intenstine - ANSWER Colonoscope 3 power sources for powered instruments - ANSWER Electricity, battery, air What protects powered surgical instruments from fluid invasion? - ANSWER Decontamination battery -Surgical instruments used to cut away at bone and tissue. - ANSWER Ronguers Another name for 400 series steel - ANSWER Martensitic the FDA classify sterilization packaging as what kind of medical device - ANSWER Class II Aluminum can only by sterilized through - ANSWER Dry heat Some Plastics including formulations of Spun bonded polyolefin are intended for use solely in these sterilization processes - ANSWER Low temperature Cellulose materials cannot be processed within a gas plasma sterilizer - ANSWER True Minimum amount of time that packaging materials should be held at room - ANSWER 2 hours Flat wrapping technique that applies one wrap on top of another to create a package within a package - ANSWER Sequential Example of reusable packing material - ANSWER Muslin a liquid oxidizing agent that effectively kills bacteria at low temps - ANSWER parecetic acid Flash sterilization can be accomplished with these three types of cycles: - ANSWER Gravity displacement, prevacuum, express the process by which a molecule, atom, or ion loses an electron. The act or process of oxidizing, chemical breakdown of nutrients for energy. - ANSWER Oxidation A material that removes debris from another substance - ANSWER Oxidizing agent A class of compounds that contain an additional atom of oxygen bound to oxygen and that uses oxidation to interrupt cell function. - ANSWER Oxidative chemistries Duration of exposure phase - ANSWER 3, 4 or 10 min traditionally called "flash" cycles, and they must be pre-programmed into the control systems of steam sterilizers. - ANSWER Gravity cycles Duration and temperature for flash sterilization load consistIng of a single instrument comprised of metal and Without lumens - ANSWER 3 min at 270 Duration of complex or lumened instruments, mixed materials, or multiple instruments - ANSWER 10 min at 270 flash cycles are standard sterilization cycles with a limited drying time - ANSWER Prevacuum Temp, duration and dry time for pre-vacuum load that consists of mixed materials or items with lumens - ANSWER 4 min at 270, 12 min The incubation temp for Geobacillus stearothermophilus is - ANSWER 122-140 A "control BI" should always be - ANSWER positive What is MIS? - ANSWER minimally invasive surgery How many people annually undergo rigid and flexible endoscopic procedures? - ANSWER 20 million A liquid chemical sterile processing system uses - ANSWER a tabletop microprocessor-controlled unit, a single use cup of PA-based sterilant, and a variety of device trays and containers. With the proper temp for is 122 -133 degrees and the exposure time to the sterilant is 12 minutes during the sterilization phase the system monitors and verifies concentration (175 or greater), temp (122-133 degrees), and exposure process (12 minutes - ANSWER Parametric monitoring steam enters the chamber as air is removed through the drain - ANSWER Conditioning phase begins when the thermocouple senses the constant pre-set cycle temp - ANSWER Exposure phase filtered air enters, steam is removed from the chamber, and the pressure inside the chamber returns to atmospheric pressure - ANSWER Exhaust phase In the event of a load recall, info about specific load contents can be obtained from: - ANSWER The sterilization log If the sterilizer successfully killed all the bacteria in a biological test, it will read as - ANSWER Negative exposure time be for a Dry Heat sterilizer that was run at 160C or 320F - ANSWER 2 hours The amount of time it takes to kill 90% of the microbes present on an object - ANSWER D-value Most efficient type of dry sterilizer - ANSWER Mechanical convection confirmation that sterilization recommendations from the manufacturer can be successfully undertaken in the hospital setting - ANSWER Verification portion of the steam sterilizer that measures steam temp and automatically controls the flow of air and condensate from the sterilizer chamber - ANSWER Thermostatic strap steam sterilization heats items within the load using a heat transfer process - ANSWER Convection Dry heat sterilization heats items within the load using a heat transfer process - ANSWER Conduction Cycle time for items sterilized using ozone sterilization_ - ANSWER 4 hours cycle time for items sterilized using hydrogen peroxide gas plasma - ANSWER <1hour The inventory system that stocks supplies by established stock levels - ANSWER Par level The number of times per year that consumable items are purchased, consumed, and replaced is called - ANSWER Inventory turnover rate items are owned by the vendor but stored at the healthcare facility - ANSWER Consignment The system where items are ordered in larger quantities to save money - ANSWER Economic order quantity consumable items that are stored in central service and other assigned storage systems can be counted as an asset on the facility's balance sheet - ANSWER Official inventory