CBSPD Exam Questions with 100% Correct Answers 2024 An inventory system whereby a supplier provides a complete inventory, storage, and distribution service for the facility and delivers to user departments on a pre- scheduled basis is known as - Correct Answer-stockless supply system
Typology: Exams
1 / 8
An inventory system whereby a supplier provides a complete inventory, storage, and distribution service for the facility and delivers to user departments on a pre- scheduled basis is known as - Correct Answer-stockless supply system The sequential compression unit would be used for which of the following conditions? - Correct Answer-to limit the development of deep vein thrombosis and peripheral edema Which of the following makes the decision whether to purchase, lease, or rent an equipment? - Correct Answer-hospital administration The packaging of choice for dry heat sterilization is - Correct Answer- aluminum foil Which of the following microorganisms is used to biologically monitor the ozone sterilizer? - Correct Answer-geobacillus stearothermophilus Which of the following should NOT be processed in a low-temperature gas plasma sterilizer? - Correct Answer-gauze sponges Which of the following packaging materials is NOT recommended for EO sterilization? - Correct Answer-nylon The basic parameters of gas sterilization in a 100% EO sterilizer are concentration, exposure time and - Correct Answer-humidity and temperature What is the minimum air exchanges to be maintained in an area where 100% EO cartridges or EO mixture cylinders are stored? - Correct Answer-10 per hour Sterilized packs are MOST likely to become contaminated - Correct Answer-within the first hour of sterilization Routine BI testing for steam sterilizers should be performed AT LEAST
control biological indicator? - Correct Answer-once a day, and if a new lot number is used Which of the following is the correct sterilizer setting for the Bowie Dick test? - Correct Answer-3.5 to 4 mins at 270 prevac
What should be done if the Bowie Dick test fails the FIRST time? - Correct Answer- repeat the test one more time Bowie-Dick falls under what class of indicator? - Correct Answer-Class II chemical A class 5 indicator is called a - Correct Answer-integrating indicator For sterilization, basin sets should be positioned - Correct Answer-tilted on their side Which action should be taken when a wet pack is noted while unloading the sterilizer? - Correct Answer-reprocess the item The absence of all forms of microbial life, including spores, is known as - Correct Answer-sterility The sterile storage area should be located - Correct Answer-adjacent to the sterilization area What should action should be taken if a reusable sterile basin set is dropped on the floor? - Correct Answer-send it to be reprocessed Items that may be subjected to storage challenges should be - Correct Answer-placed in a sterility maintenance cover be A package must be visually inspected for integrity - Correct Answer-every time it is handled Which of the following factors is a reason for assigning an expiration date to a product?
An exhaust hood over the EO sterilizer is an example of - Correct Answer- engineering control Effective sterilization begins with - Correct Answer-thorough cleaning How often should the drain line basket in a steam sterilizer be cleaned? - Correct Answer-daily Which distribution system is designed to reduce storeroom inventory? - Correct Answer- just in time Which of the following is considered a disadvantage of an exchange cart system? - Correct Answer-inventory is duplicated SPD should be capable of planning for approximately what percentage of the total needs of a unit? - Correct Answer-90 % The cochlea is part of the - Correct Answer-inner ear The optimum amount of a supply to order is called the - Correct Answer- economical order quantity Which of the following is NOT a factor affecting the dry time in a steam sterilizer - Correct Answer-selected sterilization time The hourly air exchange rate in the sterile storage area should be at least - Correct Answer- In the sterile storage area, the ventilation system must be under - Correct Answer- positive pressure EO kills micro-organisms by a process called - Correct Answer-alkylation The most unique feature of a chemical integrator is its ability to - Correct Answer- perform in parallel to a biological indicator Why must textile packs be placed on their sides for sterilization? - Correct Answer-to facilitate air removal and steam penetration Steam is exhausted from the sterilizer through the - Correct Answer-chamber drain line Failure to remove all air from a package within the steam sterilizer will result in - Correct Answer-poor steam penetration What is the most important thing to remember when double peel- pouching? - Correct Answer-the inner package must remain unsealed
An emergency eyewash station must - Correct Answer-Correct Answer permits hands- free operation Gradual heating of packs occurs during which phase of the steam sterilization cycle? - Correct Answer-conditioning What is the coldest part of the sterilizer? - Correct Answer-drain line The need for frequent reprocessing can be minimized by - Correct Answer- proper stock rotation The part of the steam sterilizer that produces heat inside the chamber to prevent condensation from forming on the chamber walls is the - Correct Answer-jacket Autoclave tape is considered which class of indicator? - Correct Answer-Class 1 The three basic shapes of microbes are round, spiral, and - Correct Answer- rod If a wrapper will be used as a sterile field, how far over the edge of the table must it extend? - Correct Answer-6 inches Where should the chemical indicator be placed when sterilizing two large basins with smaller basins on top? - Correct Answer-in the top and bottom basins Body balance is regulated by fluid in - Correct Answer-Inner Ear Bluish or rainbow-type stains are caused by BLANK in water - Correct Answer- Iron and silicates When setting up storage in the sterile storage area, the minimum amount of space storage should be kept above the floor is - Correct Answer-8-10 inches A hygrometer is a device used to measure - Correct Answer-humidity The maximum temperature permitted in the sterile storage area is - Correct Answer-75 degrees F The humidity levels in the sterile storage area should not exceed - Correct Answer-70 % The minimum amount of time items should remain on the autoclave rack, untouched, after steam sterilization is - Correct Answer-30 minutes to 2 hours
Scissors should be tested for sharpness - Correct Answer-each time they are processed The final step in the cleaning process is - Correct Answer-rinsing
When should Bowie-Dick test be performed? - Correct Answer-Each day at the same time What is the correct action to take if a written item needs to be removed from the load record? - Correct Answer-Draw a line through the item and initial Which of the following monitoring methods verifies that conditions within the load were adequate to kill bacterial spores? - Correct Answer-Biological In a mixed load of textile and metal goods, the textile packs should be placed - Correct Answer-on the top rack For sterilization, paper-plastic peel packages should be placed - Correct Answer-on their edge Which of the following is the minimum exposure time for wrapped goods in a pre- vacuum steam cycle at 275 degrees F? - Correct Answer-3 minutes Where are test packs placed to present the greatest challenge to the steam sterilizer? - Correct Answer-Over the drain What percentage of sterilization failures are caused by human error? - Correct Answer- 85 % Overloading a steam sterilizer can result in a sterilization failure by - Correct Answer- impeding air removal and sterilant penetration in the load Which of the following information is not required on a sterilization log? - Correct Answer-Number of staff working in the department The first step to take if a positive BI occurs is to - Correct Answer-review the sterilizer printout and chemical indicators The weakest part of a hinged surgical instrument is the - Correct Answer-box lock When should gross soil be removed from surgical instruments? - Correct Answer-At the point of use After sterilization, the best method to determine if packs are cool enough to release is - Correct Answer-using an infrared thermometer gun How far apart should trays and rigid containers be spaced on the sterilizer cart? - Correct Answer-1 inch AAMI recommends testing of solution be conducted - Correct Answer-before each use
Emergency eyewash stations should be - Correct Answer-placed immediately next to all strong acid or corrosive chemicals High level disinfectants should be used - Correct Answer-For devices that come in contact with the patient's mucous membranes Sterile implants are not to be released from SPD until - Correct Answer- biological test is negative A staff member brings several contaminated trays to the SPD on a cart and requests that replacement trays be put on the same cart. The technician should - Correct Answer-clean and dry the transport cart and send it to Distribution for the trays An instrument tray for a laparotomy procedure must include - Correct Answer- an abdominal retractor The Operating Room requests instruments for an emergency ruptured aortic aneurysm, which of the following instruments will the technician send? - Correct Answer-major vascular instruments Which of the following flat wrapping techniques involves applying one wrapper followed by a second one? - Correct Answer-Sequential When lifting heavy objects, which of the following muscles should bear most of the weight? - Correct Answer-Back Material Safety Data Sheets (MSDS) provide health and safety hazard and risk information on which of the following - Correct Answer-Chemical Which of the following is something that should not be allowed in sterile storage areas?