Champions School of Real Estate, 40-Hour Property & Building Inspection, Module II Latest 2024-2025. Questions & Correct Answers. Graded A
Typology: Exams
1 / 9
[Date]
_ gauge and smaller NM wire should be installed through holes in basement floor joists. - ANS# 125amp and smaller service requires _ wire for the GEC - ANS#8awg Copper 150amp+ service requires _ wire for the GEC - ANS#6awg Copper 200amp+ service requires _ wire for the GEC - ANS#4awg Copper A cable within _ of an attic access opening is considered subject to physical damage - ANS7ft vertical, 6ft horizontal A chord and plug connected appliance should not exceed _ of a general lighting branch circuit amperage rating - ANS80% An outlet is required behind the kitchen sink if the space between it and the wall is more than 12 inches - ANSTrue An unbalanced ceiling fan is out of scope and doesn't need to be reported - ANSFalse
[Date] Any point on a kitchen counter should be within _ of a receptacle - ANS2ft Any point on a wall must be within _ of a receptacle - ANS6ft Appliances that use 240v require a dedicated circuit - ANSTrue At least one GFCI protected receptacle is required in unfinished basements
[Date] Black NM wire might be what gauge? - ANS#8 or # Ceiling fans can be considered lighting fixtures - ANSFalse Convection - ANSHeat is moved by circulation of gas or liquid Countertop receptacles should be less than _ above the counter. - ANS inches Dip Tube - ANSroute the incoming cold water to the bottom of the heater. EGC - ANSEquipment grounding conductor Electrical equipment working area - ANS36" deep x 30" wide x 78" tall Electrolysis - ANSGalvanic reaction when dissimilar metals are ion contact in a moist environment Evaporator condensate tray may deteriorate or rust - ANSTrue Exterior receptacle must be within _ of the walking area/grade - ANS inches Flat NM should be stapled to framing members - ANSTrue Foyers more than 60 square ft require a receptacle on every wall that is at least 3ft wide - ANSTrue
[Date] Gas Piping cannot be used as an EGC, but must be bonded to the EGC. True or False? - ANSTrue GEC - ANSGrounding electrode conductor Ground Fault - ANSWhen electricity flows through something that is not usually energized Grounding connections can be added down stream from the main panel - ANSFalse Hallways longer than _ require a receptacle - ANS10ft Hanging Closet Storage Area - ANSFrom the floor to the highest rod or 6ft, and 2ft from the walls How many GFCI protected outlets are required in garages (attached and detached with electrical service) - ANSOne per car port If NM is ran through a hole in a framing member, it must have a nail guard if the edge of the hole is within _ of the edge - ANS1 1/4 inches Inverter - ANSChanges Direct Current into Alternating current Inverters in a PV system typically last - ANS5-15 years
[Date] It is okay for a light bulb to be exposed in a closet - ANSFalse Kitchen island receptacles can be installed on the cabinet no more than _ below the counter, as long as that countertop doesn't extend _ over the receptacle location. - ANS12 inches, 6 inches Kitchen islands or peninsulas require at least one outlet if they are larger than 2x1 feet - ANSTrue Latent Heat - ANSthe energy absorbed or released during a change in phase Light fixtures more than _ require additional support or a heavy duty electrical box - ANS50 lbs Low resistance return path - ANSCritical for proper bonding Max flexible chord length for a garbage disposal - ANS36 inches Max flexible chord length for built in washing machine - ANS78 inches Max flexible chord length for range hood and trash compactor - ANS inches Max height of a switch - ANS79 inches
[Date] Minimum distance of service drops to openings such as windows and doors
[Date] Poor airflow might result in the coil icing over - ANSTrue PVC can be used for hot water - ANSFalse PVC operating temperature is __ degrees max - ANS100 F Recessed incandescent and LED fixtures, and surface mounted fluorescent fixtures should not be located within _ of closet storage areas - ANS Inches Recessed light fixtures that are not IC rated should have _ of space from insulation - ANS3 inches Romex is a brand of - ANSNM Wire Sensible Heat - ANSthe heat we can feel and measure with a thermometer Shelf Closet Storage Area - ANSFrom the highest Shelf to the ceiling, and 12 inches from the wall Single Phase Electricity - ANSHas two conductors Solar (PV) systems generate what type of current? - ANSDirect current Stack effect - ANSHot air is lighter than cool air
[Date] Surface mounted incandescent and LED Fixtures should not be located within _ of closet storage areas - ANS12 inches Switches for exterior lights can be on the exterior - ANSFalse The evaporator coil is located before the furnace - ANSFalse The GEC must connect to the neutral _ - ANSBetween the service drop/lateral and the service equipment/main panel The laundry room requires at least one GFCI protected receptacle - ANSTrue The panels in a PV system typically last - ANS20-25 years The trap should be within __ inches horizontally, and __ inches vertically of the fixture outlet. - ANS30, 24 TP&R Valves are set to release at __ degrees - ANS210F TP&R Valves are set to release at ___psi - ANS150psi TP&R valves should be within the top _ inches of the tank. - ANS6" Track Lights can be installed in wet or damp areas - ANSFalse UF can be buried - ANSTrue
[Date] UF can service pool equipment - ANSFalse UF wire is made for - ANSWet locations Voltage/Resistance = - ANScurrent Wall receptacles are usually _ above the floor - ANS12 inches What is CSST? - ANSCorrugated Stainless Steel Tubing, usually coated in yellow plastic and used for gas connections When a gas powered appliance or water heater is in the garage the ignition source should be __ inches off the ground. - ANS18" Where should a disconnect for fixed in place appliances be available? - ANSWithin sight of the appliance Which has a slower recovery rate, Electric or gas water heaters? - ANSElectric heaters White NM wire might be what gauge? - ANS# Yellow NM wire might be what gauge? - ANS#