CMIBreathAlcoholTechnicianTrainingAssessment QuestionswithAnswersLatestUpdate2025 The breath alcohol technician training you are now receiving is in accordance to what United States Department of Transportation Regulation? - Correct Answers49 CFR Part 40 EBT is an acronym for what? - Correct AnswersEvidential Breath Tester Department of Transportation regulations require alcohol testing of transportation employees who perform __________-___________ job functions - Correct AnswersSafety-Sensitive The first breath alcohol test performed by a BAT is called a ___________ test. - Correct AnswersScreening
Typology: Exams
1 / 9
The breath alcohol technician training you are now receiving is in accordance to what United States Department of Transportation Regulation? - Correct Answers49 CFR Part 40 EBT is an acronym for what? - Correct AnswersEvidential Breath Tester Department of Transportation regulations require alcohol testing of transportation employees who perform __________-___________ job functions - Correct AnswersSafety-Sensitive The first breath alcohol test performed by a BAT is called a ___________ test. - Correct AnswersScreening The minimum waiting period between the screening alcohol test and the confirmatory alcohol test is ___ minutes. - Correct Answers How long does it take mouth alcohol to dissipate? - Correct Answers15 minutes What are two important components to ensuring a proper breath sample? - Correct AnswersTime & Pressure List the 5 reasons for a DOT-mandated alcohol test. - Correct Answers1. Random
The Intoxilyzer 240 utilizes what alcohol sensing technology? - Correct AnswersFuel Cell DOT breath alcohol test results are printed onto or attached to a? - Correct AnswersAlcohol Testing Form (ATF) Verifying the accuracy of an EBT is accomplished by a? - Correct AnswersCalibration Check QAP stands for - Correct AnswersQuality Assurance Plan The QAP developed for the Intoxilyzer 240 was developed by ____________ and approved by _________________. - Correct AnswersCMI & NHTSA According to Department of Transportation regulation, covered employees are prohibited from performing their job functions while having an alcohol concentration of ______ BAC or higher. - Correct Answers.020% Employees who have an alcohol concentration of _______ BAC or greater but less than ______BAC must be removed from covered job duties to ensure safety, but are not required to see a Substance Abuse Professional. - Correct Answers.020% & .039% Evidential Breath Testers approved for use in Department of Transportation regulated alcohol testing must be listed on ____________________________________. - Correct AnswersConforming Products List (CPL) The type of breath sample that gives the most accurate alcohol concentration result is ___________________ air. - Correct AnswersAlveolar or Deep Lung Air Indicate in the space provided, the number of years minimum an employer or BAT
serving as an "agent" for an employer must keep the following records: _____ inspection and maintenance of each EBT used in employee testing _____ calibration and calibration checks of each EBT used in employee testing _____ positive test results of .02 or greater - Correct Answers2 years 2 years 5 years The QAP requires the BAT to perform a calibration check on the Intoxilyzer 240 every _______days or after every _______ breath tests whichever comes first. - Correct Answers30 days or 50 tests True or False: 49CFR Part 40 mandates new employs must receive a pre-employment alcohol test? - Correct AnswersFalse True or False: An EBT reading of .020 BrAC is a positive breath alcohol test result. - Correct AnswersTrue True or False: The Breath Alcohol Technician (BAT) must operate the EBT in accordance with the EBT's QAP. - Correct AnswersTrue True or False: A Breath Alcohol Technician must perform the confirmatory breath alcohol test immediately after the screening test. - Correct AnswersFalse True or False: Breath alcohol instruments appearing non-asterisked on the Conforming Products List may be used for DOT mandated breath alcohol testing. - Correct AnswersTrue True or False: The Intoxilyzer 240 can be used for a confirmatory breath alcohol test only. - Correct AnswersFalse True or False: A confirmatory breath alcohol test can be performed with an EBT without printing capability. - Correct AnswersFalse
True or False: All DOT mandated breath alcohol tests must have a unique test number. - Correct AnswersTrue True or False: The DOT alcohol testing form can be used to record non-DOT mandated tests. - Correct AnswersFalse True or False: EBT calibration records need only be kept for one year. - Correct AnswersFalse True or False: The Intoxilyzer 240 automatically performs a diagnostics check when the instrument is powered on. - Correct AnswersTrue True or False: 49CFR Part 40 mandates BAT refresher training every 5 years. - Correct AnswersTrue True or False: In performing a breath test using the Intoxilyzer 240, the BAT must push the READ button after receiving indication from the instrument that a sufficient breath sample has been received. - Correct AnswersFalse Which is not necessary to include on the Alcohol Testing Form? a. Test number b. Date of test c. Time of test d. Location of test e. All of the above are included on the Alcohol Testing Form - Correct Answersd. Location of test All of the following are reasons for an cancelled test except? a. test subject will not sign Step 4 of the Alcohol Testing Form b. the instrument is outside its operating temperature range c. the mouthpiece cannot be attached
d. the printer will not print the results of a confirming test - Correct Answersa. test subject will not sign Step 4 of the Alcohol Testing Form What calibration media will you be using to perform calibration checks on the Intoxilyzer 240 a. a dry gas standard b. shot of tequila c. a wet bath simulator containing a known alcohol solution d. Scope - Correct Answersa. a dry gas standard If a confirmation test is to be performed by a different BAT than the one who per formed the screening test on the subject, the new BAT must a. use a different EBT b. start a new Alcohol Testing form c. use the same Alcohol Testing form that was used for the screening test d. use the same mouthpiece for the confirming test - Correct Answersb. start a new Alcohol Testing form After a positive confirmation test, if the test subject refuses to sign the Alcohol Testing Form in Step 4, a. the test is not invalidated by this refusal b. the test subject's employer must be contacted immediately c. the test is considered a refusal d. the BAT must give one more test which the test subject may be willing to accept - Correct Answersa. the test is not invalidated by this refusal All of the following alcohol testing occurrences must be noted in the "Remarks" section of the Alcohol Testing Form except: a. test result equal to or greater than.
b. test subject refusing to sign the Form in Step 2 c. test subject refusing to blow into the mouthpiece d. test subject leaves after test procedure begins but before test procedure is completed - Correct Answersa. test result equal to or greater than. If the alcohol concentration reading in a valid confirmation test is 0.025, the Breath Alcohol Technician must: a. observe the test subject for 15 minutes to determine if he/she is intoxicated b. immediately inform the test subject's designated employer representative c. call a Substance Abuse Professional d. tell the test subject he/she is likely to be fired - Correct Answersb. immediately inform the test subject's designated employer representative If an alcohol test must be declared cancelled, the BAT a. should begin a new test if possible b. should dismiss the test subject without attempting any more tests c. should move on immediately to the confirming test d. should dispose of the Alcohol Testing Form used for the test - Correct Answersa. should begin a new test if possible All of the following actions are permissible except: a. reusing a screening test mouthpiece for a confirming test b. rounding alcohol test results (for example, writing down a 0.019 as 0. c. performing a calibration check after each confirming test result greater than or equal to. d. both "A" and "B" - Correct Answersd. both "A" and "B" The authority for Department of Transportation mandated alcohol testing is derived from:
a. The Omnibus Transportation Employee Testing Act of 1991 b. the Bill of Rights c. the United States Constitution d. Federal Regulation 40 Part 49 - Correct Answersa. The Omnibus Transportation Employee Testing Act of 1991 If a test subject is having trouble blowing hard enough and long enough for the Intoxilyzer 240 to pull a breath sample, the BAT should a. declare the test refused b. declare the test incomplete c. invoke the manual sampling feature of the instrument while the subject is blowing through the mouthpiece and the flow indicator light is on d. send the test subject home - Correct Answersc. invoke the manual sampling feature of the instrument while the subject is blowing through the mouthpiece and the flow indicator light is on If a breath alcohol instrument fails a calibration check, which statement is true? a. all persons tested since the last valid calibration check must have failed their alcohol tests b. all alcohol tests given between the last valid calibration check and the failing calibration check will be an automatic pass c. the instrument is immediately removed from service d. the BAT disregards the calibration check result and continues to use the EBT. - Correct Answersc. the instrument is immediately removed from service All of the following are authorized to know the results of a breath alcohol test except: a. the BAT
b. the test subject's immediate supervisor c. the designated employer representative d. the subject himself - Correct Answersb. the test subject's immediate supervisor The results of a confirmatory breath alcohol test must always a. be electronically transmitted to the employer representative b. be produced in triplicate c. be kept secret form the test subject d. must be called in to the test subject's immediate supervisor - Correct Answersb. be produced in triplicate The BAT may use any of the following to identify a test subject except: a. photo ID card b. an official representative of the test subject's employer c. another test subject from the same company d. a photo driver's license - Correct Answersc. another test subject from the same company The alcohol normally consumed by humans is a. ethanol b. methanol c. isopropanol d. acetone - Correct Answersa. ethanol Acetone in the test subject's breath is not a problem with the Intoxilyzer 240 because a. it subtracts the acetone reading to get true alcohol concentration b. it does not respond to acetone in any way
c. it prevents a test from being given in the presence of acetone d. acetone compensates for an residual mouth alcohol present - Correct Answersb. it does not respond to acetone in any way Those items necessary to conduct a screening test with the Intoxilyzer 240 include: a. the instrument itself b. an Alcohol Testing Form c. both "A" and "B" d. the carrying case - Correct Answersc. both "A" and "B"