CWEA Collections Grade 2 Practice Test Questions and Answers, Exams of Nursing

A set of practice test questions and answers for the cwea collections grade 2 certification exam. It covers various topics related to wastewater collection systems, including safety procedures, traffic control, sewer maintenance, and system management. The questions are designed to assess knowledge of industry standards, regulations, and best practices.

Typology: Exams

2023/2024

Available from 12/28/2024

solutionguides
solutionguides 🇺🇸

116 documents

Partial preview of the text

Download CWEA Collections Grade 2 Practice Test Questions and Answers and more Exams Nursing in PDF only on Docsity!

1 m./

CWEA Collections Grade 2 Practice Test Questions

And Answers.

  1. Why m.are m.gasoline m.and m.volatile m.solvents m.objectionable m.when m.present m.in m.a m.sewer?:m.m.They m.produce m.an m.explosion m.hazard 2.You m.should m.never m.attempt m.to m.install, m.troubleshoot, m.maintain, m.repair, m.or m.replace m.electrical m.equipment m.unless:: m. m.You m.know m.what m.you m.are m.doing, m.arem.qualified, m.andm.arem.authorized.
  2. How m.many m.different m.areas m.of m.traffic m.zones m.are m.there m.when m.working m.in m.road- m.ways?:m.Five 4.Whym.shouldm.hydrogenm.sulfidem.bem.controlled?: m.m.m.To m.protectm.sewers m.and m.structures m.from m.corrosion 5.Personnelm.enteringm.am.Permit m.Required m.Confinedm.Space m.must m.havem.them.follow- m.ing m.training::m.m.Entry m.and m.rescue m.procedures 6. To m.find m.proper m.protective m.gear m.before m.application m.of m.a m.product,m.you m.would:- :m.m.Look m.at m.the m.MSDS m.(Material m.Safety m.Data m.Sheet)
  3. The m.gas m.most m.commonly m.associated m.with m.septic m.wastewater m.is:: m.

2 m./ m.Hydrogen m.Sulfide m.(H2S)

  1. The m.lack m.of m.an m.unpleasant m.odor m.in m.a m.structure m.does m.not m.always m.mean m.that m.dangerous m.gases m.are m.not m.present m.because:: m.Some m.dangerous m.gases m.have m.no m.odor
  2. What m.four m.conditions m.are m.necessary m.to m.create m.an m.explosion?: m.Combustible m.gas, m.adequate m.oxygen, m.sufficient m.heat, m.and m.proper m.mixing m.of m.gas m.and m.oxygen. 10.What m.does m."transition m.area" m.mean m.in m.traffic m.control?: m.Moves m.traffic m.out m.of m.itsm.normal m.path 11.The m.term m."transition m.area" m.is m.one m.component m.of m.a::m.Traffic m.Control m.Zone 12.What m.elements m.should m.be m.considered m.to m.improve m.worker m.safety m.in m.High m.Speedm.Temporarym.Traffic m.Control m.Zones?:m.Rerouting m.traffic m.around m.the m.work m.site, m.positioning m.of m.law m.enforcement m.officers m.in m.the m.temporary m.traffic m.control m.zone, m.and m.work m.zone m.training. 13.What m.key m.factors m.would m.you m.need m.to m.address m.when m.developing m.an m.S.O.P. m.for m.Lift m.Station m.failure?: m.Traffic m.control m.plan, m.by-pass m.connections, m.and m.spill m.con-m.tainment. 14."Spring m.Blades" m.are m.a m.type m.of m.tool m.used m.with:: m.Power m.Rodder 15.Porcupine, m.Root m.Saw, m.and m.a m.Square m.Bar m.Cork m.Screw m.are m.all m.tools m.used

4 m./ 20.Whenm.developingm.anm.S.O.P.m.form.scheduledm.maintenancem.ofm.electrical m.equip- m.ment,m.whatm.program m.shouldm.bem.addressed m.asm.am.primary m.safetym.guideline?:m.The L.O.T.O.m.(Lock m.Outm.Tag m.Out) m.Program

21. What m.document m.would m.you m.require m.to m.be m.referenced m.when m.developing m.an S.O.P.m.for m.hazardous m.substance m.spill m.cleanup m.as m.well m.as m.spill m.containment?:m.- M.S.D.S. 22.Placement m.of m.the m.Blower m.and m.P.P.E. m.are m.two m.things m.you m.would m.include m.in m.developing m.anm.S.O.P.m.for m.airm.monitoring m.inm.a::m.Permit m.Required m.Confined m.Space 23.According m.to m.a m.Statem.Water m.Resources m.Control m.Board m.order,m.each m.Enrollee m.must m.develop m.and m.implement m.a m.system-specific:: m.Sewer m.System m.Management m.Plan m.(SSMP) 24.Category m. 1 m.SSO's m.that m.discharge m.to m.a m.drainage m.channel m.and/or m.surface m.water m.must m.be m.reported m.within::m. 2 m.hours 25.Tom.reportm.inm.them.Statewidem.SSOm.Data-basem.California m.Integratedm.Waterm.Qual- m.ity m.System m.(CIWQS), m.regarding m.the m.location m.of m.a m.Category m. 2 m.SSO, m.you m.must m.know:: m.the m.GPS m.coordinates 26.Biological m.activity m.in m.long,m.sluggish-flow,m.flat m.grade m.sewer m.lines m.will m.likely m.cause m.odors,m.true m.or m.false?:m.True

5 m./ 27.Flatter m.sewer m.line m.grades m.may m.cause m.added m.sewer m.maintenance m.expense m.and m.odor m.nuisance. m.The m.problem m.is m.most m.likely m.caused m.by:: m.A m.decrease m.in m.velocity m.allowing m.organic m.and m.inorganic m.solids m.to m.settle m.out 28.Infiltration m.from m.a m.high m.water m.table m.can m.be m.one m.source m.of m.excessive m.clear m.water m.in m.a m.collection m.system,m.true m.or m.false?:m.True 29.What m.is m.the m.first m.thing m.to m.consider m.when m.selecting m.a m.solution m.to m.clear m.a m.stoppage m.in m.a m.sewer?:m.Cause m.of m.stoppage 30.The m.interior m.of m. 300 m.feet m.of m.12-inch m.pipe m.is m.uniformly m.coated m.with m.one m.inch m.of m.grease. m.How m.many m.gallons m.will m.this m.pipe m.hold m.when m.filled m.with m.water?: m. 12 m.inches m.(diameter m.of m.pipe) m.- m. 2 m.inches m.(grease m.on m.pipe) m.= m. 10 m.inches Convert m.inches m.to m.feet: 10 m.inches m.x m.(1 m.foot m./ m. 12 m.inches) m.= m.0.833 m.feet m.Volume m.of m.a m.right m.regular m.cylinder: V m.= m.0.785 m.x m.Diameter m.x m.Diameter m.x m.Length m.of m.Pipem.V m.= m.0.785 m.x m.0.833 m.ft m.x m.0.833 m.ft m.x m. 300 m.ft V m.= m.163.41 m.cubic m.feet m.Convert m.to

7 m./

33. Roots m.can m.enter m.collection m.systems m.through m.pipe m.cracks,m.true m.or m.false?:m.- True 34.The m.lowest m.point m.on m.the m.inside m.of m.a m.pipeline m.is m.called m.the::m.Invert 35.How m.often m.must m.an m.excavation m.site m.and m.adjacent m.areas m.be m.inspected m.for m.hazardous m.conditions?:m.Daily 36.Workingm.inm.anm.un-sloped m.trenchm.withm.nom.shoringm.ism.onem.optionm.ofm.Protective m.Shoring m.Systems, m.true m.or m.false?: m.False. m.Some m.options m.are m.proper m.stopping m.or m.benching m.ofm.them.sides m.ofm.them.excavation, m.supporting m.them.sides m.ofm.a m.trench m.with m.shoring, m.and m.using m.a m.shield m.in m.the m.excavation m.area. 37.Proper m.operation m.and m.maintenance m.of m.wastewater m.collection m.is m.keeping m.wastewater m.flowing m.through m.pipes,m.true m.or m.false?:m.True 38.Minimumm.designm.velocitym.form.am.sewerm.shouldm.greaterm.than::m. 2 m.feet m.per m.second 39.Vitrified m.Clay m.pipe m.is m.a m.Rigid m.type m.of m.pipe,m.true m.or m.false?:m.True 40.Barrels, m.lids,m.cones,m.and m.backflow m.devices m.are m.all m.included m.in m.Manholes, m.true m.or m.false?:m.False. m.All m.are m.included m.except m.for m.backflow m.devices. 41.Sewer m.testing m.methods m.include m.air,m.water, m.mandrill, m.and m.sewage,m.true m.or m.false?:m.False. m.Sewer m.testing m.methods m.do m.not m.include m.sewage. 42.Using m.high m.velocity m.cleaners m.is m.one m.method m.included m.in m.hydraulic m.sewer

8 m./ m.cleaning,m.true m.or m.false?:m.True 43.A m.flow m.of m. 650 m.gpm m.would m.be m.how m.many m.MGD?:m. 650 m.gpm m.x m.(1440 m.min m./ m. 1 m.day) = m. 936000 m.gpd 936000 m.x m.(1 m.MG m./ m. 1000000 m.gal) m.= m.0.936 m.MGD 44.One m.of m.the m.advantages m.of m.using m.CCTV m.is m.that m.the m.length m.and m.severity m.of m.defective m.pipe m.areas m.can m.be m.recorded,m.true m.or m.false?:m.True 45.Offset m.joints m.are m.one m.hazard m.that m.may m.damage m.am.TV m.camera m.going m.through m.a m.sewer,m.true m.or m.false?:m.True 46.What m.is m.the m.total m.volume m.of m. 1000 m.feet m.of m. 8 m.inch m.line?:m.Convert m.inches m.to m.feet: m. 8 m.inches m.x m.(1 m.foot m./ m. 12 m.inches) m.= m.0. Volume m.of m.a m.right m.regular m.cylinder: V m.= m.0.785 m.x m.Diameter m.x m.Diameter m.x m.Length m.of m.Pipem.V m.= m.0.785 m.x m.0.666 m.ft m.x m.0.666 m.ft m.x m. 1000 m.ft V m.= m.348.19 m.cu m.ft m.Convert m.to m.gallons: 348.19 m.cu m.ft m.x m.(7.48 m.gal m./ m. 1 m.cu m.ft) m.= m.2604.47 m.gal

10 Area m.= m.0.785 m.x m.0.667 m.ft m.x m.0.667 m.ft m.= m.0. m.sq m.ft m.Convert m.flow m.in m.gallons m.to m.cubic m.feet m.per m.second: (400000 m.gal m./ m. 1 m.day) m.x m.(1 m.cu m.ft m./ m.7.48 m.gal) m.x m.(1 m.day m./ m. 24 m.hours) m.x m.(1 m.hr m./ m. 60 m.min) m.x m.(1m.min m./ m. 60 m.sec) m.= m.0.619 m.cu m.fps Velocity m.= m.0.619 m.cu m.fps m./ m.0. m.sq m.ftm.Velocity m.= m.1.77 m.fps 48.Duringm.them.24-hourm.operation m.am.liftm.stationm.pumpedm. 3000 m.gallonsm.perm.minute m.for m.a m.community m.of m.27000. m.What m.is m.the m.per m.capita m.pumped m.in m.gallons m.per m.day?:m.GPD m./ m.Capita m.=m.Volume m.Pumped m.Per m.Day m./ m.Number m.of m.people Volume m.= m.(3000 m.gal m./ m. 1 m.min) m.x m.(60 m.min m./ m. 1 m.hr) m.x m.(24 m.hr m./ m. 1 m.day) m.Volume m.= m. 4320000 m.gal GPD m./ m.Capita m.= m. 4320000 m.gal m./ m. 27000 m.people m.GPD m./ m.Capita m.= m. 160 49.Am.wetm.well m. 20 m.feet m.in m.diameter m.is m.filled m.with m.water m.to m.a m.depth m.of m. 10 m.feet.m.How m.many m.gallons m.does m.the m.tank m.contain?: m.Volume m.= m.0.785 m.x m.Diameter m.x m.Diameter m.xm.Height Volume m.= m.0.785 m.x m. 20 m.ft m.x m. 20 m.ft m.x m. 10 m.ft m.Volume m.= m. 3140 m.cu m.ft

11 Convert m.to m.gallons: 3140 m.cu m.ft m.x m.(7.48 m.gal m./ m. 1 m.cu m.ft) m.= m.23487.2 m.gal 50.One m.way m.members m.of m.a m.bailing m.crew m.can m.communicate m.with m.each m.other m.is m.by m.using m.hand m.signals,m.true m.or m.false?:m.True 51.Why m.must m.you m.always m.know m.the m.distance m.when m.a m.cleaning m.tool m.is m.in m.a m.sewer?:m.So m.you m.know m.where m.obstructions m.or m.difficulties m.are m.encountered 52.Emergency m.stoppages m.in m.pipelines m.may m.be m.cleared m.safely m.by m.use m.of m.high m.velocity m.cleaners,m.true m.or m.false?:m.True 53.Rodents m.and m.insects m.can m.be m.controlled m.by m.spraying m.manholes m.with m.an m.approved m.pesticide,m.true m.or m.false?:m.True 54.How m.many m.types m.of m.common m.shoring m.are m.there?:m. 6 55.Ifm.itm.takesm. 7 m.minutes m.and m. 30 m.secondsm.form.dyem.tom.travel m.am.distancem.ofm. 860 m.feet m.through m.an m. 8 m.inch m.sewer, m.what m.is m.the m.velocity m.in m.feet m.per m.second?: m.Velocity m.= m.Distance m./m.Time Convert m.minutes m.to m.seconds: 7 m.min m.(60 m.sec m./ m. 1 m.min) m.= m. 420 m.sec m.Velocity m.= m. 860 m.ft m./ m.(420 m.sec m.

  • m. 30 m.sec)m.Velocity m.= m. 860 m.ft m./

13 x m.Diameter m.x m.Height Volume m.= m.0.785 m.x m. 12 m.ft m.x m. 12 m.ft m.x m. 8 m.ftm.Volume m.= m.904.32 m.cu m.ft 57.Once m.enrolled m.in m.CIWQS,m.the m."Collection m.System m.Questionnaire" m.must m.be m.updated m.at m.least m.every::m. 12 m.months 58.You m.received m.a m.sewer m.spill m.call m.at m. 1100 m.hours, m.arrived m.on m.site m.at m.1115, m.and m.your m.crew m.relieved m.the m.stoppage m.at m.1127. m.You m.estimate m.the m.spill m.was m.running m.at m. 6 m.gallons m.per m.minute.m.How m.much m.sewer m.went m.un-captured?:m.Duration m.x m.Flowm.Rate m.= m.Spillm.Volume 27 m.min m.x m. 6 m.gpm m.= m. 162 m.gallons 59.Liftm.stationm.failurem.canm.includem.electrical m.circuitm.failures,m.truem.orm.false?:m.True 60.Am.cloggedm.impellerm.canm.causem.am.pumpm.tom.deliverm.lessm.thanm.itsm.expectedm.rate m.of m.discharge,m.true m.or m.false?:m.True 61.Why m.are m.wear m.rings m.installed m.in m.a m.pump?:m.To m.concentrate m.wear m.on m.ringsm.instead m.of m.volute m.and m.impeller 62.Floats m.can m.be m.used m.to m.start m.or m.stop m.pumps,m.true m.or m.false?:m.True 63.Submersible m.pumps m.can m.be m.used m.in m.wet m.wells,m.true m.or m.false?:m.True 64.Centrifugal m.pump m.parts m.include m.a m.volute,m.true m.or m.false?:m.True 65.You m.receive m.a m.call m.at m.4:30 m.pm m.about m.a m.sewer m.spill m.that m.was m.seen m.spilling

14 m.since m. 2 m.pm.m.You m.arrive m.at m.5:15 m.pm m.and m.estimate m.the m.sewer m.spilling m.at m. 166 m.gpm.m.You m.clear m.the m.stopage m. 22 m.minutes m.after m.your m.arrival. m.How m.many m.gallons m.were m.unrecoverable?:m.Duration m.x m.Flow m.Rate m.= m.Spillm.Volume 217 m.min m.x m. 166 m.gpm m.= m. 36022 m.gal 66.How m.long m.is m.an m.Inquiry m.Identification m.Number m.for m.an m.Underground m.Service m.Alert m.(USA) m.viable m.for?:m. 28 m.days 67.A m.person m.who m.completes m.a m.training m.program m.in m.accordance m.with m.the m.re- m.quirements m.ofm.Title m.8,m.Calif.m.Code m.of m.Regulations,m.Minimum m.Guidelines m.of m.them.Common m.Ground m.Alliance m.is m.considered m.a m.Qualified m.Person,m.true m.or m.false?:m.-m.True 68.Temporary m.traffic m.control m.lanes m.created m.as m.part m.of m.a m.Temporary m.Traffic m.Control m.Zonem.setupm.on m.am.street m.with m.am. 35 m.MPHm.maximum m.speed m.limit m.shallm.bem.a m.minimum m.width m.of::m. 10 m.feet 69.For m.a m.night m.time m.Short m.Term m.Stationary m.Temporary m.Traffic m.Control m.Zone m.setupm.onm.lowm.speed/low m.volumem.street,m.them.minimumm.heightm.ofm.them.traffic m.conesm.used m.shall m.be::m. 28 m.inches 70.Afterm.completingm.am.Temporarym.Traffic m.Control m.setupm.for m.your m.work m.zonem.itm.is m.a m.good m.practice m.to:: m.Observe m.how m.effective m.your m.TTC m.setup m.is m.working m.to m.control m.traffic m.and m.make m.the m.necessary m.changes m.to m.it m.if m.necessary