Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

EPA 608 CORE TEST EXAM|| LATEST 2024-2025 QUESTIONS AND 100% CORRECT ANSWERS ALREADY GRA, Exams of Nursing

EPA 608 CORE TEST EXAM|| LATEST 2024-2025 QUESTIONS AND 100% CORRECT ANSWERS ALREADY GRADED A+|| LATEST AND COMPLETE UPDATE 2024-2025 WITH VERIFIED SOLUTIONS|| ASSURED PASS!!

Typology: Exams

2024/2025

Available from 12/02/2024

Examiner2025
Examiner2025 ๐Ÿ‡บ๐Ÿ‡ธ

5

(1)

2.9K documents

1 / 111

Toggle sidebar

Related documents


Partial preview of the text

Download EPA 608 CORE TEST EXAM|| LATEST 2024-2025 QUESTIONS AND 100% CORRECT ANSWERS ALREADY GRA and more Exams Nursing in PDF only on Docsity!

EPA 608 CORE TEST EXAM|| LATEST 2024- 2025

QUESTIONS AND 100% CORRECT ANSWERS

ALREADY GRADED A+|| LATEST AND COMPLETE

UPDATE 2024-2025 WITH VERIFIED SOLUTIONS||

ASSURED PASS!!!

As of what date did it become unlawful to release Class 1 and Class II refrigerants to the atmosphere? a. July 1, 1992 b. July 1, 1993 c. November 14, 1994 d. January 1, 1996 - โˆš - ANSWER: a. July 1, 1992 Quiz :What is the ozone layer and why is it important to us on Earth? a. Thin layer of R-22 in the atmosphere that filters UV. b. Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that extends about 6 to 30 miles above earth c. Thin layer of CFC and HCFC in the atmosphere that filters UV. d. Protective layer that shields UV in the Troposphere - โˆš - ANSWER: b. Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that extends about 6 to 30 miles above earth

b. Quiz :The atom found in CFC and HCFC refrigerants that destroys ozone in the stratosphere is? a. Fluorine Carbon c. Hydrogen d. Chlorine - โˆš - ANSWER: d. Chlorine Quiz :What is an ozone molecule made of? a. Refrigerant b. Ammonia c. Three oxygen atoms (O3). d. Oxygen and ammonia. - โˆš - ANSWER: Three oxygen atoms (O3). Quiz :Which refrigerant is a CFC? a. R-134A b. R- 123 c. R- 22 d. R- 12 - โˆš - ANSWER: d. R- 12 Quiz :What is the name of the atom that attacks ozone molecules? a. CFC atoms

b. b. HCFC atoms c. Chlorine and bromine atoms emitted into the atmosphere d. a and b - โˆš - ANSWER: c. Chlorine and bromine atoms emitted into the atmosphere Quiz :Which refrigerant is a HFC? a. R-134A R- 123 c. R- 22 d. R- 12 - โˆš - ANSWER: a. R-134A Quiz :Describe how one Chlorine atom can destroy 100,000 ozone molecules. a. Chlorine releases one of the oxygen atoms and forms two O2 oxygen molecules, leaving the chlorine molecule free to attack another ozone molecule and repeat the process. b. Chlorine locks up the ozone molecule and then and then goes after another. c. Chlorine converts the ozone to bromine and then attacks more ozone molecules. d. Chlorine can bleach 100,000 ozone molecules before it weakens. - โˆš - ANSWER: a. Chlorine releases one of the oxygen atoms and forms two

b. O2 oxygen molecules, leaving the chlorine molecule free to attack another ozone molecule and repeat the process. Quiz :Which refrigerant contains no chlorine? a. R-134A b. R- 123 c. R- 22 d. R- 12 - โˆš - ANSWER: a. R-134A Quiz :Name the refrigerant types that belong to CFCs, HCFCs and HFCs a. CFC R-11, R-12, R- 500 HCFC R-22, R- 123 c. HFC R-134a d. All of the above are correct - โˆš - ANSWER: d. All of the above are correct Quiz :The rule of thumb for refilling approved cylinders is a maximum of ___ percent liquid? a. 60% b. 79% c. 80% d. 90% - โˆš - ANSWER: c. 80%

b. Quiz :What do the letters in "HCFC" stand for? a. High Carbon Fluorine Chlorine b. hydrochlorofluorocarbons c. Harmful Carbon Fluorine Chlorine d. highchlorinefluorocarbon - โˆš - ANSWER: b. hydrochlorofluorocarbons Quiz :To recover refrigerant is to? a. Remove a refrigerant in any condition from a system in either an active or passive manner, and store it in an external container without necessarily testing or processing b. Reduce contaminants in used refrigerant by oil separation through filter dryers. c. Reprocess refrigerant to new product specifications

d. Remove refrigerant and change ownership. - โˆš - ANSWER: a. Remove a refrigerant in any condition from a system in either an active or passive manner, and store it in an external container without necessarily testing or processing Quiz :What is ODP? a. Oxygen Destruction Properties b. Ozone Depletion Potential c. Ozone Destruction Properties d. Oxygen Depletion Potential - โˆš - ANSWER: b. Ozone Depletion Potential Quiz :R-134A is a "drop in" refrigerant for? 36 | P a g e a. R- 12 b. R- 22 c. R- 11 d. R-134A is not a drop-in refrigerant - โˆš - ANSWER: d. R-134A is not a drop-in refrigerant Quiz :Name some of the health and environmental effects of ozone depletion. a. Increased Temperature of the Earth b. Increased Cases of Skin Cancer c. Increased numbers of Cataracts in the eyes

d. All the above - โˆš - ANSWER: d. All the above Quiz :The condition and state of the refrigerant leaving a receiver is? a. Subcooled liquid b. Subcooled vapor c. Superheated vapor d. Superheated liquid. - โˆš - ANSWER: a. Subcooled liquid Quiz :What evidence do we have that CFCs and HCFCs are depleting the ozone? a. The rise in the amount of chlorine measured in the stratosphere over the past two decades matches the rise in the amount of fluorine. b. The rise in the amount of chlorine measured in the stratosphere over the past two decades matches the rise in CFC emissions over the same period. c. Samples of air taken from the stratosphere over erupting volcanoes show that volcanoes contribute a small quantity of chlorine to the stratosphere compared to CFCs. d. All the above - โˆš - ANSWER: d. All the above Quiz :The component of an air conditioning system that changes a low pressure vapor to a high pressure vapor is the? a. Condenser b. Metering device c. Evaporator

d. Compressor 20.What characteristics - โˆš - ANSWER: d. Compressor Quiz :What characteristics make it easy for CFCs to reach the stratosphere and how do they get there? a. CFCs are lighter than air atoms and rise into the Stratosphere. b. CFCs will not dissolve in water or break down into compounds that dissolve in water. Wind moves them into the Stratosphere c. Heating of the CFCs makes them lighter than air. d. a and c - โˆš - ANSWER: b. CFCs will not dissolve in water or break down into compounds that dissolve in water. Wind moves them into the Stratosphere Quiz :Why do we now use R-134a refrigerant? a. It costs less b. HFCs do not contain any chlorine c. It is a drop in replacement for R- 22 d. It is a drop in replacement for R- 11 - โˆš - ANSWER: b. HFCs do not contain any chlorine Quiz :What is the purpose of the CAA? 37 | P a g e a. Regulate California Air quality b. Clean the air in the US

c. Limit how much of a pollutant can be in the air in the US - โˆš - ANSWER: c. Limit how much of a pollutant can be in the air in the US Quiz :What three things is the CAA doing to control chlorofluorocarbon emissions? a. Set dates to phase out CFC's and HCFC's b. Prohibit venting of CFC and HCFC c. Require the EPA to set standards for recovery of refrigerants prior to appliance disposal d. All the above - โˆš - ANSWER: d. All the above Quiz :What can states do in addition to the CAA? a. Enforce standards more strict than the CAA laws b. Nothing c. States can create their own laws. d. All of the above - โˆš - ANSWER: a. Enforce standards more strict than the CAA laws Quiz :What three things can happen if you violate the CAA? a. Fine up to $27,500 per day, per violation b. May lose your certification to handle refrigerants c. May need to appear in US Federal Court for the charges

d. All the above - โˆš - ANSWER: d. All the above Quiz :What incentive do others have to turn you in for violating the CAA? a. An award of up to $10,000 is offered by the EPA b. An award of up to $100,000 is offered by the EPA c. An award of up to $1,000 is offered by the EPA d. None of the above - โˆš - ANSWER: An award of up to $10,000 is offered by the EPA Quiz :Who can purchase refrigerants and what size cylinders can be purchased? a. Only certified technicians may purchase refrigerants as of November 14, 1994 b. The smallest cylinder a 608 certified technician may purchase is 20 lbs c. A certified technician can purchase HCFC d. All the above - โˆš - ANSWER: Quiz :What is the Montreal Protocol? a. Treaty between Canada and the US to limit use of refrigerants b. Treaty among nations designed to protect the stratospheric ozone layer. c. Method to clean the air developed in Montreal d. Carbon regulation - โˆš - ANSWER: b. Treaty among nations designed to protect the stratospheric ozone layer.

Quiz :What chemicals does the Montreal Protocol control? a. chlorofluorocarbons (CFCs), halons, b. carbon tetrachloride c. methyl chloroform d. All the above - โˆš - ANSWER: d. All the above Quiz :When was the CFC phase out date? a. November 31, 2003 b. December 31, 1995 c. November 15, 1990 d. November 15, 1993 - โˆš - ANSWER: b. December 31, 1995

Quiz :Where do CFC refrigerants come from for equipment servicing of older systems? a. DuPont b. Government warehouse

c. Recovery and recycling d. Imported from South America - โˆš - ANSWER: c. Recovery and recycling Quiz :What must be done before scrapping a refrigerant container? a. Release the refrigerant b. Recover to (0 psig) or lower and rendered useless c. Punch a hole in the container d. Add compressed air - โˆš - ANSWER: b. Recover to (0 psig) or lower and rendered useless Quiz :What must be done before disposing of an appliance containing CFCs or HCFCs? a. Identify refrigerant by attaching DOE tag. b. Identify refrigerant by attaching CAA tag c. Identify refrigerant by attaching EPA tag d. Refrigerant must be recovered - โˆš - ANSWER: d. Refrigerant must be recovered Quiz :Who is responsible for removing refrigerants from a system that is being disposed of? a. HVACR tech

b. EPA c. Original owner d. Final person in the disposal chain - โˆš - ANSWER: d. Final person in the disposal chain Quiz :Are there "drop-in" replacements for R-12 systems and if not, why? a. There is no "drop-in" replacement gas for R- 12 b. New refrigerants are incompatible with the oils and lubricants used in R- 12 c. 134A uses a different oil than R- 12 d. All the above - โˆš - ANSWER: d. All the above Quiz :What type of oil is used in R-134a and what oils will mix with it? a. Ester based oils b. Ester based oils do not mix with other oils. c. Synthetic alkylbenzene lubricant d. a and b - โˆš - ANSWER: d. a and b Quiz :Will the gases in a ternary blend leak at the same rate and why or why not? a. They leak at different rates because they retain their different vapor pressures. b. They leak at the same rate. A leak is a leak. c. Ternary blends have the same vapor pressure.

d. All the above - โˆš - ANSWER: a. They leak at different rates because they retain their different vapor pressures. Quiz :What does a compressor compress? a. Liquid refrigerant b. Hot vapor c. High pressure vapor d. Low pressure, low temperature vapor - โˆš - ANSWER: d. Low pressure, low temperature vapor Quiz :Explain how cooling of a space occurs in a refrigeration cycle a. The indoor air is cooled b. Heat is removed from inside the building and is deposited outside the building c. Liquid refrigerant absorbs the heat and transfers it to the exterior. d. Cold liquid refrigerant cools the indoor air. - โˆš - ANSWER: b. Heat is removed from inside the building and is deposited outside the building Quiz :Will refrigerant migrate to the crank case in a compressor? a. Refrigerant seeks the lowest point in the system, the compressor crankcase. b. Refrigerant vaporizes and does not collect tin the compressor. c. Oil migrates to the compressor crankcase.

d. Refrigerant will migrate towards the compressor crank case while the oil will not - โˆš - ANSWER: d. Refrigerant will migrate towards the compressor crank case while the oil will not Quiz :What color is the compound gauge and what does the compound gauge measure? a. Blue and measures low pressure (psig) and vacuum (inches Hg) b. Red and measures head pressure c. Yellow and measures vacuum - โˆš - ANSWER: a. Blue and measures low pressure (psig) and vacuum (inches Hg) Quiz :What color is the high pressure gauge? a. Blue and measures high pressure b. Red and measures the high side (discharge) pressure c. Red and measures low side pressure d. Yellow and measures high pressure - โˆš - ANSWER: b. Red and measures the high side (discharge) pressure Quiz :What are three things the center hose is used for and what color is it usually? a. Red, high pressure, low pressure and vacuum b. Yellow hose and can be connected to a recovery device, evacuation vacuum pump or charging device c. Blue, low pressure, vacuum and recovery

d. Green, recovery, vacuum, low and high pressure - โˆš - ANSWER: b. Yellow hose and can be connected to a recovery device, evacuation vacuum pump or charging device Quiz :What things should you look for in equipment and systems to help limit refrigerant emissions? a. Equipment used is approved by the EPA b. Leak check, repairing leaks c. Making sure that all fittings are tight during service and recovery d. All the above - โˆš - ANSWER: d. All the above Quiz :What is the most effective method for checking for small leaks? a. Leak noise

b. Refrigerant dye c. Pressurize with nitrogen d. Halide torch - โˆš - ANSWER: d. Halide torch Quiz :How can you test a system for leaks? a. Evacuate the system and pull a vacuum on it b. Use a hydrostatic test c. Pressurize with oxygen d. Use water pressure - โˆš - ANSWER: a. Evacuate the system and pull a vacuum on it Quiz :What should you look for if a compressor burns out? a. Frayed wires b. Check paint on compressor body c. Strong smell in refrigerant d. Melted tubing - โˆš - ANSWER: c. Strong smell in refrigerant Quiz :What will need to happen if the oil has been contaminated by a burnout? a. Triple evacuate the system b. Install a permanent filter-drier c. Conduct a deep vacuum before recharging

b. d. All the above - โˆš - ANSWER: d. All the above Quiz :How is recovery different from recycling? a. Recycle is to clean refrigerant for immediate reuse Recover is to remove refrigerant in any condition from a system and store it in an external container c. There is no difference d. a and b - โˆš - ANSWER: d. a and b Quiz :How is recycling different from reclaiming? a. Recycling must be performed by a recycling plant b. Recycle is to clean c. Reclaim is to process refrigerant to the level of new product specifications d. b and c - โˆš - ANSWER: d. b and c Quiz :Name reasons recovery is important? a. To have adequate supplies of refrigerant for service after production bans b. Prevent venting to the atmosphere c. Prevent stratospheric ozone depletion d. All the above - โˆš - ANSWER: d. All the above

b. Quiz :What standards must refrigerant recovery equipment meet? a. Certified and labeled by an EPA approved equipment manufacturer b. None c. CAA approval d. DOT standards and labeling - โˆš - ANSWER: a. Certified and labeled by an EPA approved Quiz :What are types of recovery equipment used? a. System dependent Self-contained c. Container less d. a and b - โˆš - ANSWER: d. a and b Quiz :What should you tell a consumer who complains about the added cost and time of recovering refrigerant? a. Recovery is the law. b. Recovery is necessary to protect human health and the environment. c. All professional service personnel are duty bound to follow the law and protect the environment. d. All of the above - โˆš - ANSWER: d. All of the above Quiz :How should you handle recovery of a system that has mixed refrigerants? a. Recover into a separate tank b. Vent the refrigerant

b. c. Call the EPA d. Call the police - โˆš - ANSWER: Quiz :After recovery, what are nitrogen and a filter drier used for? a. Dry the system. b. Filter dryer is used to clean the nitrogen before removal c. Flush debris and trap any debris d. All of the above - โˆš - ANSWER: a. Recover into a separate tank

Quiz :What are the variables that affect the recovery rate? a. Size of refrigeration system and recovery equipment b. Size of suction hose, c. Temperatures. d. All of the above - โˆš - ANSWER: c. Flush debris and trap any debris Quiz :Why is it important to have faster recovery? a. Taking longer increases chance of emissions of the refrigerants to the atmosphere b. Faster recovery saves energy c. Faster recovery removes oil d. All of the above - โˆš - ANSWER: a. Taking longer increases chance of emissions of the refrigerants to the atmosphere Quiz :If you smell a strong odor during recovery, what is most likely the problem? a. Compressor has burned out b. Sour gas c. Pressure is too high d. Recovery machine is overloaded - โˆš - ANSWER: a. Compressor has burned out

Quiz :Why is it necessary to dehydrate a refrigeration system? a. Remove water from a hydrostatic pressure test b. Remove debris from the system c. Remove ice contaminates d. Remove water and water vapor contaminating the system - โˆš - ANSWER: d. Remove water and water vapor contaminating the system Quiz :What happens if moisture is left in an operating refrigeration system? a. Freezes up b. Create highly corrosive and toxic acids c. Increases head pressure d. Reduces head pressure - โˆš - ANSWER: b. Create highly corrosive and toxic acids Quiz :What must be done before starting evacuation? a. Install nitrogen b. Install dryer c. Recover all refrigerant d. Install site glass - โˆš - ANSWER: c. Recover all refrigerant Quiz :What are the four factors that affect the evacuation time? a. Size of equipment being evacuated,

b. Ambient temperature, Amount of moisture, c. Capacity of vacuum pump and suction line d. All of the above - โˆš - ANSWER: d. All of the above Quiz :Can you increase the temperature of a refrigeration system for evacuation and if so, what purpose does it have? a. Yes. Decrease the evacuation time by increasing pressure b. No. It increases time by increasing pressure c. No. Creates danger of explosion d. None of the above - โˆš - ANSWER: a. Yes. Decrease the evacuation time by increasing pressure Quiz :How long and what diameter should the piping connection to the vacuum pump be? a. 3 feet and 3/8" b. 2.5 feet and 3/8" c. 2 feet and 3/8" d. As short in length as possible and as wide in diameter as possible - โˆš - ANSWER: d. As short in length as possible and as wide in diameter as possible Quiz :How big should the vacuum hoses be in relation to the pump intake connection?

a. One size larger than pump intake connection b. Equal to or larger than the pump intake connection c. One and a half size larger than pump intake connection d. None of the above - โˆš - ANSWER: b. Equal to or larger than the pump intake connection Quiz :For accurate vacuum readings, where should the vacuum gauge be located? a. Close to the vacuum pump b. Between the vacuum pump and unit c. As far as possible from the vacuum pump d. On the vacuum pump - โˆš - ANSWER: c. As far as possible from the vacuum pump Quiz :When should the measurement of vacuum for a system be done and how do we know when dehydration is complete? a. With the system isolated and vacuum pump turned on. Dehydration is considered complete when the vacuum gauge shows that have reached and held the required finished vacuum b. With the system open and vacuum pump turned off. Dehydration is considered complete when the vacuum gauge shows that have reached and held the required finished vacuum