Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

EPA 608 Type 1 Exam Questions with Complete Solutions 2024, Exams of Refrigeration and Air Conditioning

EPA 608 Type 1 Exam Questions with Complete Solutions 2024

Typology: Exams

2023/2024

Available from 07/09/2024

TheHub
TheHub 🇺🇸

3.6

(11)

3K documents

1 / 4

Toggle sidebar

Related documents


Partial preview of the text

Download EPA 608 Type 1 Exam Questions with Complete Solutions 2024 and more Exams Refrigeration and Air Conditioning in PDF only on Docsity! EPA 608 Type 1 Exam Questions with Complete Solutions 2024 Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after November 15, 1993 Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: recovering 80% of the refrigerant whether or not the compressor is operating or achieving a 4 inch vacuum under conditions of ARI 740-1993 EPA's definition of a small appliance includes: a device manufactored, charges & hermeticly sealed in factory with a charge of 5lbs or less Tech's with a type 1 small appliance certification are certified to recover refrigerant during the maintenance or repair of: PTAC's with 5lbs or less of refrigerant EPA requires that all small appliances be equipped with a service aperture or other device that is used when adding or removing refrigerant from the appliance. For small appliances this service port typically a straight piece of tubing, called a process tube that is entered using a piercing valve The EPA section 608 certification must be renewed every never It is an EPS regulation that any person who opens and appliance for maintenance, service or repair must have at least one self-contained recovery machine avalible at their place of buisiness. The only exception to this rule are persons working on small appliances The sale od CFC & HCFC refrigerants is: restricted to techs who are EPA certified in refrigerant recovery Anyone who recovers refrigeration during maintenance, service or repair of small appliances must be certified as either a universal Tech or a: Type 1 tech When recovering refrigerant from a household refrigerator who's compressor does not run, it is recommended that a low and high side access valves be installed because: it can help speed of recovery and required recovery effiency If you install an access fitting into a sealed system: the fitting should be leak tested before proceeding with recovery Before beginning a refrigerant recovery procedure it is alway necessary to: determine the type of refrigerant in the system when recovering refrigerant into a non-pressurized container from a refrigerator with an improper compressor: it is necessary to heat & strike the compressor with a rubber mallet When checking for the existence of noncondensable gases inside a recovery cyclinder, why is it proper procedure to allow the temperature of the cyclinder to stabilize @ room temperature before taking a pressure reading? any comparisons to a pressure-temperature chart is only valid if both the pressure & temperature of the refrigerant are stable A recovery cyclinder which is 1/2 full of recovered R-410A @ 90*F, in the absence of non- condensables will be presurized to: 300 psig. When using ______, it is essential to take extra measures (heating/striking), to help release trapped refrigerant from the compressor oil. passive system-dependdent recovery devices on a small appliance with a non-operating compressor. According to the EPA which recovery equipment maintenance practice(s) should be preformed on a regular basis? check recovery device for refrigerant leaks On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves that are needed to evacuate the refrigerant 1 valve on the high side Which refrigerant is most commonly used as a replacement for R-12 in new household refrigerators R-134a Small amounts of refrigerant have no odor, therefor a pungent odor is detected during a system recovery &/or repair: a compressor burn-out has likely occurred