Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

F02 EXAM (Fire Guard for Shelter NY) PRACTICE TEST 45 QUESTIONS WITH VERIFIED CORRECT ANSW, Exams of Nursing

F02 EXAM (Fire Guard for Shelter NY) PRACTICE TEST 45 QUESTIONS WITH VERIFIED CORRECT ANSWERS Building occupants - correct answer -All persons in the building, including employees, building personnel and visitors. CENTRAL STATION COMPANY - correct answer -A facility that receives alarm signals from a protected premise and retransmits or otherwise reports such alarm signals to the FDNY. EMERGENCY PREPAREDNESS PLAN - correct answer -also known as the fire safety and evacuation plan and/or emergency action plan.

Typology: Exams

2023/2024

Available from 08/07/2024

PassingMaster
PassingMaster 🇰🇪

3.4

(5)

678 documents

1 / 8

Toggle sidebar

Related documents


Partial preview of the text

Download F02 EXAM (Fire Guard for Shelter NY) PRACTICE TEST 45 QUESTIONS WITH VERIFIED CORRECT ANSW and more Exams Nursing in PDF only on Docsity! F02 EXAM (Fire Guard for Shelter NY) PRACTICE TEST 45 QUESTIONS WITH VERIFIED CORRECT ANSWERS Building occupants - correct answer -All persons in the building, including employees, building personnel and visitors. CENTRAL STATION COMPANY - correct answer -A facility that receives alarm signals from a protected premise and retransmits or otherwise reports such alarm signals to the FDNY. EMERGENCY PREPAREDNESS PLAN - correct answer -also known as the fire safety and evacuation plan and/or emergency action plan. EVACUATION - correct answer -- the emptying of a building of all building occupants in response to a fire or an emergency FIRE ALARM SYSTEM - correct answer -- any system, including any interconnected fire alarm sub-system, of components and circuits arranged to monitor and annunciate the status of fire alarm or supervisory signal- initiating devices. FIRE GUARD - correct answer -- A person holding a Certificate of Fitness for such purposes, who is trained in and responsible for maintaining a fire watch. FIRE PROTECTION SYSTEMS - correct answer -- Approved devices, equipment and systems or combinations of systems used to detect a fire, activate an alarm, extinguish or control a fire, control or manage fire alarm systems, sprinkler systems and standpipe systems FIRE WATCH - correct answer -A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, including detecting early signs of fire, raising an alarm of fire, notifying the department, and performing such other fire safety duties as may be prescribed by the commissioner. IMPAIRMENT - correct answer -- Any condition in which a fire protection system cannot perform its designed fire safety function. IMPAIRMENT COORDINATOR - correct answer -- The person designated by the building owner who is responsible for ensuring that proper notification and safety precautions are taken when a standpipe system, sprinkler system or fire alarm system is out of services NON-FIRE EMERGENCY - correct answer -A biological, chemical or nuclear incident or release; declaration of emergency by a lawful authority; explosion; medical emergency; natural disaster; or other emergency affecting the premises or the safety of building occupants. OWNER/OCCUPANT RESPONSIBILITY - - correct answer -The owner shall be responsible at all times for the safe maintenance of a building, structure and premises in accordance with this code. Elevator lobby smoke detectors - - correct answer -detectors that when activated will recall elevators automatically to the designated landing. Beam detectors - correct answer -are used to protect large areas where area smoke detectors are not practical. This detector consists of a light beam that when broken by any combustible particle will trigger the detector. Duct smoke detectors - correct answer -are designed to sample air flow in the HVAC air duct and to detect the presence of particles of combustion. These smoke detectors will upon activation, shutdown the system's fan. Heat detectors - correct answer -- A sensor that detects abnormally high temperatures or rate of temperature rise. The rate-of-rise heat detectors - correct answer -activate the alarm when the room temperature increases at a rapid rate. This type of detector is more sensitive than the fixed temperature detector. The rate-of-rise heat detector does not have to be replaced after it has activated the fire alarm. Fixed-temperature heat detectors - correct answer -activate the alarm when the detector components melt at a preset temperature level. The fixed-temperature heat detectors normally require replacement after they have sounded an alarm. However, intelligent heat detectors will usually reset themselves. Carbon Monoxide Alarm - correct answer -A single or multiple-station alarm responsive to carbon monoxide, containing a build-in initiation sensor, notification device, and power supply and is not connected to a system. Carbon Monoxide Detector - correct answer -A device that sounds an alarm when a dangerous level of carbon monoxide is reached A device that is responsive to carbon monoxide and is connected to the fire alarm control panel. required in any building that has fossil (gas and oil) fuel burning equipments. Carbon monoxide detectors - correct answer -shall be installed, tested, and maintained by qualified personnel in accordance with the manufacturers published instructions. A sprinkler water flow detector - correct answer -is a device which initiates an alarm indicating a flow of water in a sprinkler system. It is designed to signal when water flows through the fire protection system Audio and visual notification devices - correct answer -are fire alarm system components such as bells, horns, speakers, lights or text displays that provide audible, tactile or visible out puts or any combination thereof. One way voice communication - correct answer -entails the use of a public address system. Two way voice communication - correct answer -is a form of transmission in which both parties involved have the ability to transmit information uses warden phones that are placed at several locations throughout the building, usually near the exit stairways in the building. The sprinkler system - correct answer -Detect fire and automatic distribute water on fire. Activation of the sprinkler system shall cause an alarm to be transmitted to an approved central station and will also sound an alarm throughout the shelter. Automatic Sprinkler System - correct answer -System of water pipes, discharge nozzles, and control valves designed to activate during fires by automatically discharging enough water to control or extinguish a fire. Non-automatic Sprinkler System - correct answer -Sprinkler piping with or without fusible heads but supplied with water only by the FDC Sprinkler heads - correct answer -must never be painted over and must not accumulate dust and debris. It must be replaced immediately with a new sprinkler head if they have been painted over or have accumulated debris