Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNY G60 PRACTICE TEST 100% VERIFIED ANSWERS 2024/2025 CORRECT STUDY SET, Exams of Organization and Business Administration

FDNY G60 PRACTICE TEST 100% VERIFIED ANSWERS 2024/2025 CORRECT STUDY SET

Typology: Exams

2024/2025

Available from 12/06/2024

SUPERIORSCORES
SUPERIORSCORES 🇺🇸

3.9

(13)

4K documents

Partial preview of the text

Download FDNY G60 PRACTICE TEST 100% VERIFIED ANSWERS 2024/2025 CORRECT STUDY SET and more Exams Organization and Business Administration in PDF only on Docsity!

FDNY G60 PRACTICE TEST

100% VERIFIED ANSWERS

2024/2025 CORRECT STUDY

SET

SPRINKLER SYSTEM MUST NOT BE SHUT OFF OR IMPAIRED WHILE HOT WORK IS PERFORMED

PLACE DAMP CLOTH GUARDS ON INDIVIDUAL SPRINKLER HEADS

THE PERSON CONDUCTING THE FIRE WATCH ______ HAVE OTHER DUTIES

CANNOT

A PORTABLE FIRE EXTINGUISHER WITH A RATING OF _________ IS REQUIRED AND SHOULD BE

WITHIN ____ FEET TRAVEL DISTANCE HOT WORK AREA

2 - A:20-B:C///

FOR ROOFING OPERATIONS, A PORTABLE FIRE EXTINGUISHER WITH A MINIMUM RATING OF

______ IS REQUIRED

3 - A:40-B:C

FIRE WATCH ON FLOORS BELOW IS ______

REQUIRED

THE FIRE WATCH MUST CONTINUE FOR A MINIMUM OF ____ MINUTES AFTER THE HOT WORK IS

DONE

FOR ANY CNG OR LPG TORCH OPERATIONS, THE FIRST INSPECTION SHALL BE CONDUCTED ___

MINUTES AFTER COMPLETION. THE SECOND INSPECTION SHALL BE CONDUCTED _______ AFTER

COMPLETION OF TORCH OPERATIONS.

30 MIN///1 HOUR

THE FIRE GUARD OR FIRE WATCH PERSONNEL MUST COMPLETE A SIGNED INSPECTION REPORT

AND IT MUST BE SUBMITTED TO AND RETAINED BY THE PERSON IN CHARGE OF THE TORCH

OPERATIONS.

THE REPORT MUST BE MADE AVAILABLE AND MAINTAINED ON THE PREMISES FOR A MINIMUM OF

48 HOURS AFTER THE WORK IS COMPLETE.

MOST COMMON FUEL GASSES USED IN BLOWTORCHES ARE ______

LPG (BUTANE, PROPANE) NATURAL GAS (METHANE) (EITHER CNG OR PIPED NATURAL GASSES)

SOLDERING AND BRAZING TEMPERATURES ARE TYPICALLY______

840 DEGREES F

OXY-ACETYLENE GENERATES THE HIGHEST TEMPERATURE WHICH CAN REACH UP TO _____

6000 DEGREES F

GAS TORCHES CAN EXCEED _________ AND ARE USED FOR BURNING WEEDS, MELTING ICE, OR

APPLYING TAR TO A ROOF

2000 DEGREES F

IF THE TORCH OPERATION IS TO STOP FOR A PERIOD OF _________________, THE TORCH VALE

MUST BE CLOSED AND THE GAS SUPPLY TO THE TORCH MUST BE COMPLETELY SHUT

1 HOUR OR MORE

CONTAINERS, VALVES, REGULATORS, HOSE AND OTHER APPARATUS AND FITTINGS FOR OXYGEN

MUST BE KEPT FREE OF __________.

OIL OR GREASE

BACKFIRE

THIS OCCURS WHEN THE FLAME OF A TORCH GOES OUT AND THERE IS A LOUD SNAP OR POP

FLASHBACK

THIS OCCURS WHEN THE CUTTING OR WELDING FLAME BURNS INSIDE THE TORCH OR THE HOSES

AND IT IS USUALLY ACCOMPANIED BY A WHISTLE OR HISSING NOISE. AS SOON AS IT IS NOTICED, THE

TORCH CONTROL VALVES SHOULD BE CLOSED. THIS INDICATED THERE IS SOMETHING WRONG WITH

THE EQUIPMENT, EITHER DAMAGE OR BLOCKAGE

A HOT WORK AREA SHOULD BE _____

WELL VENTILATED

WHOEVER IS WORKING WITH HOT WORK EQUIPMENT CANNOT WEAR _____________ SINCE IT IS

SUSCEPTIBLE TO BURNING AND IGNITION

FRAYED CLOTHING

EMPTY CONTAINERS MUST BE __________

HANDLED IN THE SAME MANNER AS FULL ONES

GAS CONTAINERS MUST BE REPLACED WHEN EMPTY.

IT IS ILLEGAL TO REFILL GAS CONTAINER

ALL GAS CONTAINERS, WHETHER CNG OR LPG, MUST BE SECURED IN AN __________

UPRIGHT POSITION AND MUST NOT BE STACKED OR STORED ON SHELVES

ALL GAS CONTAINERS AND RELATED EQUIPMENT MUST BE _________

PROTECTED FROM EXTREME TEMPERATURE AND PHYSICAL DAMAGE

THE CONTROL VALVE OF ANY GAS CONTAINER MUST BE _______

OPENED BY HAND

ACETYLENE VALVES SHALL NOT BE OPENED MORE THAN ______

1 ½ TURNS

THE PURPOSE OF A REGULATOR IS TO ________

CONTROL THE FLOW OF GAS AND LOWER THE PRESSURE FROM THE CONTAINER TO THE APPLIANCE.

IT ALSO ACTS LIKE A SAFELY BARRIER BETWEEN THE HIGH PRESSURE OF THE GAS CONTAINER AND

THE END USE APPLIANCE

HOSES MUST BE AS _______ PROTECTING FROM MECHANICAL INJURY

SHORT AS PRACTICAL

NO HOSE IS ALLOWED TO EXCEED ____FEET

A COMPRESSED GAS CONTAINER MUST NOT ________

BE ROLLED ON ITS SIDE OR ITS RIM, ONLY BY APPROVED LIFTING EQUIPMENT

ROPES, CHAINS OR SLINGS SHALL NOT BE USED TO ________

SUSPEND COMPRESSED GAS CONTAINERS UNLESS SUCH CONTAINERS HAVE BEEN DESIGNED FOR

SUCH HANDLING

CNG AND LPG CONTAINERS MUST BE LOCATED _______

AWAY FROM ELECTRIC POWER LINES, PIPING CONTAINING FLAMMABLE OR COMBUSTIBLE LIQUIDS,

PIPING CONTAINING FLAMMABLE GASSES, AND PIPING CONTAINING OXIDIZING MATERIALS

FUEL GAS OR OXYGEN CONTAINERS IN STORAGE MUST BE SEPARATED FROM ANY COMBUSTIBLE

MATERIALS BY A MINIMUM DISTANCE OF _____

20 FEET

OXIDIZING GASSES SHALL NOT BE STORED OR USED OR COME IN CONTACT WITH _______

OIL, GREASE OR OTHER PETROLEUM BASES

A PERMIT IS REQUIRED FOR ANY STORAGE AREA STORING ANY FLAMMABLE GAS IN EXCESS OF

____ OR ANY OXYGEN IN EXCESS OF ____

400 SCF///504 SCF

COPPER TUBING SHOULD NEVER ______

BE USED TO SPLICE THE ACETYLENE HOSE BECAUSE THE COPPER WITH REACT WITH THE ACETYLENE

AND IT CAN CAUSE AN EXPLOSION

NEVER SET THE REGULATOR FOR LPG ABOVE ____ AS THE ACETYLENE WILL DECOMPOSE

EXPLOSIVELY

15 PSI

EXAMPLES OF LPG

PROPANE, PROPYLENE, BUTANE, AND BUTYLENE

MOST COMMONLY USED LPG IS ____

BUTANE AND PROPANE

LPG IS MOST COMMONLY REFERRED TO AS _____

BOTTLED GAS

LPG IS NATURALLY _______

COLORLESS AND ODORLESS

LPG IS HEAVIER THAN _____

AIR

LPG CONTAINERS MUST BE TESTED BY DOT APPROVED VENDORS EVERY _______

5 YEARS

LPG CONTAINERS CAN BE A MAXIMUM WEIGHT OF _____

100 POUNDS

LPG MUST BE ONLY USED IN _________, NOT UNDERGROUND

WELL VENTILATED AREAS

LPG CONTAINERS WITH A WEIGHT OF _______ SHALL BE PROVIDED WITH TRANSPORTATION

PLUGS

20 POUNDS

CNG IS MAINLY COMPOSED OF ____

METHANE

ANY SINGLE CNG CONTAINER MUST NOT EXCEED ______

381 SCF

THE C OF F HOLDER MUST NOT _______

ATTEMPT TO DO ANY REPAIRS, BUT ONLY TAKE THE EQUIPMENT OUT OF SERVICE

ALWAYS CHECK LEAKS WITH _______

SOAP AND WATER

PASS

PULL, AIM, SQUEEZE, SWEEP

NO FIRE EXTINGUISHER IS ALLOWED TO BE ______

PLACED ON THE FLOOR

ALWAYS APPROACH A FIRE FROM A _______

UPWIND DIRECTION

CLASS A =

CLASS B =

CLASS C =

CLASS D =

CLASS K =

COMBUSTIBLE MATERIALS (PAPER, CARDBOARD)

FLAMMABLES (OIL, KEROSENE)

ELECTRICAL EQUIPMENT

COMBUSTIBLE METALS

COOKING STUFF

FIRE EXTINGUISHERS ARE TO BE INSPECTED AND CHECKED _______

MONTHLY