Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNYC F60 Fireguard Test 2024 Questions with Verified Answers Latest Update, Exams of Nursing

FDNYC F60 Fireguard Test 2024 Questions with Verified Answers Latest Update

Typology: Exams

2023/2024

Available from 04/11/2024

josh1990
josh1990 🇺🇸

5

(2)

2.4K documents

1 / 13

Toggle sidebar

Often downloaded together


Related documents


Partial preview of the text

Download FDNYC F60 Fireguard Test 2024 Questions with Verified Answers Latest Update and more Exams Nursing in PDF only on Docsity!

FDNYC F60 Fireguard Test 2024

Questions with Verified Answers Latest

Update

The Certificate of Fitness holder must keep the Certificates of Fitness upon his or her person, or otherwise __________________ for inspection by any representative of the Department, at all times while conducting or supervising the material, operation or facility for which the certificate is required. - answers ✅✅Readily Available Permits issued by the FDNY are required to conduct the following hot work: - answers ✅✅1) Storing, Using or Handling Oxygen and a Flammable gas

  1. LPG or CNG or Acetylene in excess of 400 SCF
  2. Any oxidizing gas in excess of 504 SCF Portable LPG containers that are more than ____________ must NOT be stored, handled, or used indoors - answers ✅✅16. oz

CNG containers with a capacity greater than ____________ must NOT store, handled, or used on the roof - answers ✅✅8. SCF Use of LPG/Propane on an occupied roof requires an ____________________ from licensed professional ___________________ stating the roof is constructed of ________________________ - answers ✅✅Affidavit, Architect or Engineer, non-combustible materials Any single standard portable LPG container must not exceed _______________ in weight - answers ✅✅100 LBS Any single CNG container must not exceed ______________ SCF - answers ✅✅ 381 Such permit authorizes the permit holder to store, handle, or use flammable gases, or conduct a torch operation at a specific premises or location called? - answers ✅✅Site-specific permit A ____________________________ may be a permanent permit or a temporary permit. - answers ✅✅Site-specific permit

Under _______________________________ a permanent permits are valid for ___________only - answers ✅✅Site-specific permit, 12 months Under ________________________a temporary permit may be valid from _______to____________ depends on the construction/operation need. - answers ✅✅Site-specific permit, 1 day to 12 months Such permit authorizes the permit holder to store, handle, use or sell hazardous material or conduct an operation on a citywide basis is called? - answers ✅✅Citywide permit Such permit is valid to temporarily store, handle, use or sell hazardous materials or to conduct an operation at one or more locations is called? - answers ✅✅Citywide permit Citywide permit the duration of such activity at any individual location does not exceed __________________ days - answers ✅✅30 calendar

Periods of activity in excess 30 calendar days at any one location shall require a __________________________ - answers ✅✅Site-specific permit What should be readily available on the premise for inspection by Fire Department representatives? - answers ✅✅Any and all permits Hot work program authorization is NOT issued by the FDNY, it must be signed and issued by the __________________ - answers ✅✅Responsible person Hot work shall be available for inspection by any representative for ______________ after the work is completed - answers ✅✅48 hours For hot work operation with citywide permit, the owner of the premises of the hot work operation areas must be notified in writing by the citywide permit holder at least ______________ the hot work is to be started - answers ✅✅48 hours before

Before hot work is authorized and at least _______________ while the authorization is in effect, the hot work area shall be inspected by the responsible person - answers ✅✅once per day The pre-hot work check must be conducted by the ________________ before hot work is authorized and at least ____________________ - answers ✅✅responsible person, once per day Hot work area must be kept ___________ feet away from any combustible materials and combustible waste - answers ✅✅ 35 feet All other hot work operations shall be conducted at least _____________ feet away from any combustible materials and combustible waste - answers ✅✅25 feet Sprinkler system protection ___________________________ while hot work is performed. - answers ✅✅must not be shut off or impaired

Gas Torch Operation Precautions - answers ✅✅Each person must operate only one torch at a time and such torch must not be left unattended while ignited Protection of Combustibles - answers ✅✅Areas designed for hot work operations shall have floors with noncombustible surface Paper, wood shavings, straw and fabric are examples of ________________________ - answers ✅✅combustible materials Hot work operations involving cutting or welding shall be conducted at least __________________ from combustible materials and combustible waste - answers ✅✅35 feet ____________________ shall not be allowed to accumulate on floors and other surfaces within the hot work area. - answers ✅✅Combustible waste Prohibited cutting or welding when ________________________ - answers ✅✅supported by or resting on any compressed gas containers

Compressed gas containers must be replaced when __________________ - answers ✅✅They are empty Empty containers must be handling in the same manners as __________________ - answers ✅✅full once A ________________ must not be rolled on its side or its rim - answers ✅✅Compressed gas containers Fire Watch Requirement - answers ✅✅A fire watch must be maintained during any hot work operation Person conducting a fire watch ______________ - answers ✅✅shall not have other duties Fire Guard vs Fire Watch - answers ✅✅-important to understand the code required distinction between fire watch and a fire guard-not all individuals responsible to maintain a fire watch must possess an f-60 certificate of fitness Under Fire watch at least once portable fire extinguisher with minimum _______________ rating must be readily available

within __________ feet travel distance of the location - answers ✅✅2-A:20-B:C, 30 feet Under fire watch torch applied roof systems, a minimum _____________ rating fire extinguisher readily available - answers ✅✅3-A 40-B:C Torch Applied Roof-System - answers ✅✅Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion. Under Time and Record keeping for any CNG or LPG torch operation timing, ___________ - answers ✅✅the first inspection shall be conducted 30 minutes after completion of torch operations; the second inspection 1 hour after completion of torch operations The fire guards or fire watch personnel must complete a signed inspection report (or the log book). This report must be submitted to and retained by the person in charge of the torch operations. The log book should be_________________ - answers ✅✅maintained on the premises for 48 hours after work is complete

Under Gas Welding and Cutting Precautions - The torch valves shall be closed and the gas supply to the torch completely shut off when hot work operations are discontinues for a period of ________________ or more - answers ✅✅1 hour Tests for suspected leaks in piping equipment and systems shall be made using ______________________ - answers ✅✅soapy water Emergency notification - answers ✅✅-fire guard can use wireless phone to make emergency notifications (make sure that battery is charged to last the entire shift)-notifying FDNY by phone is the most direct and effective way to make notification of an emergency Fire Detection System - answers ✅✅fire watch for impairment must be provided when the alarm system is offline A portable fire extinguisher with at least 2-A:20--B:C rating... - answers ✅✅must be readily accessible within 30 feet of the location where hot work is performed and where the fire guards are positioned

-in case of fire, 911 must be called In event of a fire extinguisher has been discharged... - answers ✅✅a fully charged replace meant is required before work can resume Portable fire extinguishers are important in? - answers ✅✅- preventing a small fire from growing into a larger one -not intended to fight large or spreading fire The C of F holder should only consider extinguishing a fire when? - answers ✅✅they are limited in size and spread such that they can be readily extinguished using a portable fire extinguisher P.A.S.S. - answers ✅✅Pull, Aim, Squeeze, Sweep All fire extinguishers installed so that? - answers ✅✅the top of the extinguisher is not more than 5 ft above the floor and the clearance between the bottom of the extinguisher and the floor is less than 4in.-in other words, no fire extinguisher is allowed to put on the floor

Where to point the extinguisher to extinguish a fire... - answers ✅✅the dry chemical stream must be directed toward the point where the flame begins

  • DO NOT direct the chemical stream at the center of the flame, this will not extinguish the fire Extinguishing a gas fire caused by a leak... - answers ✅✅-easiest way to extinguish this fire is to shut off by using the emergency shut off valve until the flame is extinguished Extinguished piped gas - answers ✅✅-for piped gas, the gas supply must be shut off first then call 911 -never attempt to extinguish the flame unless the gas supply is shut -when not possible to shut off the gas supply (e.g. the fire is near the control valve or the shut-off valve) and the gas supply is limited (e.g. it is from a cylinder) allow the flame to burn itself out and call 911-in meantime, prevent fire spreading to the surrounding materials Class A fire - answers ✅✅-Fires caused by ordinary combustibles such as wood, paper, cloth, and plastic fires

-to extinguish a class A fire, these extinguishers utilize either the heat -absorbing effects of water or the coating effects of certain dry chemicals Class B Fire - answers ✅✅-fires are caused by flammable or combustible liquids and gases such as oil, gasoline, etc. -to extinguish. The blanket-smothering effect of oxygen excluding media such as CO2, dry chemical or foam is most effective Class C Fire - answers ✅✅-fires that involve electrical equipment- these fires must be fought with extinguishers that do not conduct electricity -foam and water type extinguishers must not be used to extinguish electrical fires -after shutting off the electrical equipment, extinguishers for Class A or B fires may be used Class D Fire - answers ✅✅-fires caused by ignitable metals, such as magnesium, titanium, and metallic sodium, or metals that are combustible under certain conditions, such as calcium, zinc, and aluminum

-generally, water should not be used to extinguish these fires Fire extinguisher inspections - answers ✅✅-must be done monthly -owner of premises is responsible to designate a person to perform a monthly inspection -"quick check" CNG - answers ✅✅compressed natural gas LPG - answers ✅✅liquefied petroleum gas SCF - answers ✅✅Standard Cubic Feet