  1. Automatic sprinkler heads should be: covered by a damp cloth and removed after hot work
  2. A permit is required for storing a flammable gas in excess of: 400 scf
  3. Acetylene burns at: 3000 degrees Fahrenheit
  4. It is dangerous to use fuel gas at pressures above: 15 psi
  5. A fire extinguisher must be mounted: so that the top is not more than 5 feet off the floor
  6. To extinguish a fire: Always approach the fire from upwind
  7. PASS stands for: Pull, Aim, Squeeze, Sweep
  8. In the case of any fire,: The FDNY must be notified
  9. For piped gas,: the gas should be shut off first
  10. Oxygen cylinders are made of: Steel
  11. A temporary permit to conduct torch operations is valid from: 1 day to 12 months
  12. A hot work permit is required for: welding
  1. A spark producing tool: requires a Fire Guard
  2. Soldering and brazing temperatures are typically: 840 degrees Fahrenheit
  3. Oxy-Acetylene can generate a temperature of up to: 6000 degrees Fahren- heit
  4. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a: Hot Work Area
  5. A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a: Fire Guard
  6. Most fires are the result of: sparks
  7. What should you do if ice buildup occurs on the gas cylinder itself?: call 911 immediately

holder every: year

  1. A type D fire involves: Combustible Metals
  2. A type of clothing that should not be worn when performing torch opera- tions is: Frayed Clothing.
  3. A flame going out unexpectedly and creating a popping sound is known as: Backfire.
  4. When a cutting or welding flame burns inside a torch is known as: Flash- back.
  5. To check for a leak one should: Use a soap and water solution.
  6. A work area should be: Well ventilated.
  7. To extinguish a fire: Always approach the fire from upwind.
  8. How should a gas cylinder be stored?: Upright and not on shelves.
  9. In the case of any fire,: The FDNY must be notified.
  10. Acetylene valves should not be opened more than: 1 1/2 turns
  11. "SCF" stands for: Standard Cubic Feet
  12. A Certificate of Fitness Holder must keep his or her certificate: On their person.
  13. A Citywide permit is valid for up to: 30 Days
  14. A hot work permit is required for: Welding.
  1. A spark producing tool: Requires a Fire Guard.

valid for?: 30 days

  1. How many Fire Guards are required on a job site that has 3 torches in operation?: One per torch and additional one stationed on the floor below.
  2. Portable LPG containers greater than must not be stored in resi- dential occupancies.: 16.4 oz.
  3. An oxygen cylinder may store gas at pressure up to: 2200 psi.
  4. A Responsible Person is one who is: trained in the fire safety hazards asso- ciated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises.
  5. A designated Hot Work area must be at least feet away from com- bustible materials.: 35.
  6. For all Hot Work, inspections must be completed after completion of torch operations.: 30 minutes.
  7. A minimum rating Fire Extinguisher must be readily accessi- ble within of the hot work location for torch operations.: 2 - A:20-B:C, 30 feet.
  8. For a Torch-applied Roof System, a minimum rating Fire Extinguisher must be readily accessible within .: 3 - A: 40 - B:C, 30 feet.
  1. Empty compressed gas cylinders: Should be handled in the same manner as full ones.
  2. Panic Bar: A device fitted on the inside of a door that would allow a person to push against a door to open it.
  3. A type of valve typically used in sprinkler systems: OS & Y Valve- Outside Screw and Yoke Valve.
  4. Fire Drill: A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan.
  5. shall not be considered a fire: flame used in any lawful, properly operating device, equipment or system or other controlled setting.
  6. Fire Watch: A temporary measure intended to ensure continuous and system- atic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department.
  7. Hot Work: Cutting, welding, thermit welding, brazing, soldering, grinding, ther- mal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity.

10 / 6

  1. A fire guard is responsible for: overseeing torch operations.
  1. The pre-hot work check must be conducted by: the responsible person before hot work is authorized and at least once per day.
  2. The check reports must be kept at the work site: maintained on the premis- es for a minimum of 48 hours after work is complete.
  3. Exhaust fans: may be used to draw the fumes away from the work area
  4. The workers should: wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs
  5. All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current ANS Certificate of Fitness
  6. The Certificate of Fitness holder ANS must regulate the pressure and flow of oxygenand natural gas to each torch.
  7. if the torch operator for jewelry manufacture involves ANS any oxygen with anyfuel gas containers, the operator must be a C of F holder.
  8. A Certificate of Fitness Holder must keep his or her certificate ANS on their person or otherwise readily available for inspection by any representative of the fireDepartment
  9. The easiest way to extinguish a fire caused by a leak is to

defined in the Building code): residential occupancies,factory and industrial occupancies; educational occupancies; institutional occupan-cies, except as the commissioner may authorize by rule.

  1. Site-specific permit ANS may be a permanent permit or a temporary permit. Per-manent permits are valid for 12 months only
    1. A city-wide permit is valid ANS up to 30 days
    2. Permits shall be ANS readily available on the premise for inspection by Fire Depart-ment representatives. 100.Hot work authorization should be issued by the responsible person, and it ANS must be available for inspection by any representative of the department duringthe performance of the work, and for 48 hours after the work is complete 101.FDNY permits ANS will be posted in a central location and recorded in a log bookto assist in the coordination of construction related activities.

102.CNG: Compressed Natural Gas.

  1. For Citywide hot work operations, the Owner of the premises must be notified in writing at least hours in advance prior to work beginning.: 48 104.A class A fire extinguisher fights fires from: Paper 105.How old must a candidate be in order to earn a Certificate of Fitness?: 18 Years Old 106.What type of fire is a Class B fire extinguisher used on?: Oil 107.Examples of combustibles include: Newspaper 108.An example of a flammable material would be: Gasoline 109.Fire extinguishers must be inspected once every: Month 110.A work area should be: Well Ventilated 111.A type C fire involves: Live electrical equipment