Download FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Que and more Exams Nursing in PDF only on Docsity! FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - Correct Answers ✅Certificate of Fitness The Certificate of Fitness holder - Correct Answers ✅must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves - Correct Answers ✅any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate - Correct Answers ✅on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to - Correct Answers ✅close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: - Correct Answers ✅storing, using or handling oxygen and a flammable gas, FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is - Correct Answers ✅approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit - Correct Answers ✅14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - Correct Answers ✅must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions A work area should be - Correct Answers ✅Well Ventilated A type C fire involves - Correct Answers ✅Live electrical equipment Automatic sprinkler heads should be - Correct Answers ✅covered by a damp cloth and removed after hot work A permit is required for storing a flammable gas in excess of - Correct Answers ✅400 scf Acetylene burns at - Correct Answers ✅3000 degrees Fahrenheit It is dangerous to use fuel gas at pressures above - Correct Answers ✅15 psi A fire extinguisher must be mounted - Correct Answers ✅so that the top is not more than 5 feet off the floor FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions To extinguish a fire - Correct Answers ✅Always approach the fire from upwind PASS stands for - Correct Answers ✅Pull, Aim, Squeeze, Sweep In the case of any fire, - Correct Answers ✅The FDNY must be notified For piped gas, - Correct Answers ✅the gas should be shut off first Oxygen cylinders are made of - Correct Answers ✅Steel A temporary permit to conduct torch operations is valid from - Correct Answers ✅1 day to 12 months A hot work permit is required for - Correct Answers ✅welding A spark producing tool - Correct Answers ✅requires a Fire Guard FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions Soldering and brazing temperatures are typically - Correct Answers ✅840 degrees Fahrenheit Oxy-Acetylene can generate a temperature of up to - Correct Answers ✅6000 degrees Fahrenheit An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - Correct Answers ✅Hot Work Area A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a - Correct Answers ✅Fire Guard Most fires are the result of - Correct Answers ✅sparks What should you do if ice buildup occurs on the gas cylinder itself? - Correct Answers ✅call 911 immediately If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should - Correct Answers ✅take it out of service FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions A flame going out unexpectedly and creating a popping sound is known as - Correct Answers ✅Backfire. When a cutting or welding flame burns inside a torch is known as - Correct Answers ✅Flashback. To check for a leak one should - Correct Answers ✅Use a soap and water solution. A fire extinguisher must be mounted - Correct Answers ✅so that the top is not more than 5 feet off the floor A work area should be - Correct Answers ✅Well ventilated. To extinguish a fire - Correct Answers ✅Always approach the fire from upwind. How should a gas cylinder be stored? - Correct Answers ✅Upright and not on shelves. FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions In the case of any fire, - Correct Answers ✅The FDNY must be notified. Acetylene valves should not be opened more than - Correct Answers ✅1 1/2 turns "SCF" stands for - Correct Answers ✅Standard Cubic Feet A Certificate of Fitness Holder must keep his or her certificate - Correct Answers ✅On their person. A Citywide permit is valid for up to - Correct Answers ✅30 Days A hot work permit is required for - Correct Answers ✅Welding. A spark producing tool - Correct Answers ✅Requires a Fire Guard. To prevent injury hoses should be - Correct Answers ✅As short as practical. FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions The oxygen cylinder - Correct Answers ✅is made of steel and contains 100% oxygen. A compressed gas container must - Correct Answers ✅Not be rolled on its side. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - Correct Answers ✅Hot work area. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of - Correct Answers ✅20 feet. Most fires are the result of - Correct Answers ✅Sparks. Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. - Correct Answers ✅60. FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. - Correct Answers ✅2-A:20-B:C, 30 feet. For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. - Correct Answers ✅3-A: 40-B:C, 30 feet. Empty compressed gas cylinders - Correct Answers ✅Should be handled in the same manner as full ones. Panic Bar - Correct Answers ✅A device fitted on the inside of a door that would allow a person to push against a door to open it. A type of valve typically used in sprinkler systems - Correct Answers ✅OS & Y Valve- Outside Screw and Yoke Valve. Fire Drill - Correct Answers ✅A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan. shall not be considered a fire - Correct Answers ✅flame used in any lawful, properly operating device, equipment or system or other controlled setting. Fire Watch - Correct Answers ✅A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department. Hot Work - Correct Answers ✅Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity. Torch Applied Roof-System - Correct Answers ✅Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion. FDNYC G60 Practice Exam Questions and Answers (Latest 2023) (100% Correct Answers) 112 Questions Egress - Correct Answers ✅A means of exit from a fire or other emergency. Single Action fire alarm pull station - Correct Answers ✅requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors. Double Action fire alarm pull station - Correct Answers ✅Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside. All gas containers and the related equipment - Correct Answers ✅must be protected from extreme temperature and physical damage. Any single standard portable LPG container must not exceed - Correct Answers ✅100 lbs in weight. Any single CNG container must not exceed - Correct Answers ✅381 SCF.