Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNYC G60 Practice Exam Questions with Verified Answers., Exercises of Company Secretarial Practice

FDNYC G60 Practice Exam Questions with Verified Answers.FDNYC G60 Practice Exam Questions with Verified Answers.FDNYC G60 Practice Exam Questions with Verified Answers.

Typology: Exercises

2023/2024

Available from 08/28/2024

Bestgrader
Bestgrader 🇺🇸

4.1

(17)

551 documents

1 / 7

Toggle sidebar

Related documents


Partial preview of the text

Download FDNYC G60 Practice Exam Questions with Verified Answers. and more Exercises Company Secretarial Practice in PDF only on Docsity! FDNYC G60 Practice Exam Q uestions with Verified Answers. All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - ANS Certificate of Fitness The Certificate of Fitness holder - ANS must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves - ANS any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate - ANS on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to - ANS close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: - ANS storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is - ANS approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit - ANS 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - ANS must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit - ANS may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid - ANS up to 30 days Permits shall be - ANS readily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it - ANS must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete FDNY permits - ANS will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities. CNG - ANS Compressed Natural Gas. For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning. - ANS 48 A class A fire extinguisher fights fires from - ANS Paper How old must a candidate be in order to earn a Certificate of Fitness? - ANS 18 Years Old What type of fire is a Class B fire extinguisher used on? - ANS Oil Examples of combustibles include - ANS Newspaper An example of a flammable material would be - ANS Gasoline Fire extinguishers must be inspected once every - ANS Month A work area should be - ANS Well Ventilated A type C fire involves - ANS Live electrical equipment Automatic sprinkler heads should be - ANS covered by a damp cloth and removed after hot work A permit is required for storing a flammable gas in excess of - ANS 400 scf Acetylene burns at - ANS 3000 degrees Fahrenheit It is dangerous to use fuel gas at pressures above - ANS 15 psi A fire extinguisher must be mounted - ANS so that the top is not more than 5 feet off the floor To extinguish a fire - ANS Always approach the fire from upwind A spark producing tool - ANS Requires a Fire Guard. To prevent injury hoses should be - ANS As short as practical. The oxygen cylinder - ANS is made of steel and contains 100% oxygen. A compressed gas container must - ANS Not be rolled on its side. An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - ANS Hot work area. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of - ANS 20 feet. Most fires are the result of - ANS Sparks. Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. - ANS 60. Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials. - ANS 35. If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut. - ANS One hour or more. A torch should be ignited by using a - ANS Friction device. Why should oil or grease not be used near oxygen? - ANS It might cause an explosion. How long is a site permanent specific permit to store flammable gases valid for? - ANS 30 days How many Fire Guards are required on a job site that has 3 torches in operation? - ANS One per torch and additional one stationed on the floor below. Portable LPG containers greater than ______ must not be stored in residential occupancies. - ANS 16.4 oz. An oxygen cylinder may store gas at pressure up to - ANS 2200 psi. A Responsible Person is one who is - ANS trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises. A designated Hot Work area must be at least_______ feet away from combustible materials. - ANS 35. For all Hot Work, inspections must be completed_______ after completion of torch operations. - ANS 30 minutes. A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. - ANS 2-A:20-B:C, 30 feet. For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. - ANS 3-A: 40-B:C, 30 feet. Empty compressed gas cylinders - ANS Should be handled in the same manner as full ones. Panic Bar - ANS A device fitted on the inside of a door that would allow a person to push against a door to open it. A type of valve typically used in sprinkler systems - ANS OS & Y Valve- Outside Screw and Yoke Valve. Fire Drill - ANS A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan. shall not be considered a fire - ANS flame used in any lawful, properly operating device, equipment or system or other controlled setting. Fire Watch - ANS A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department. Hot Work - ANS Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity. Torch Applied Roof-System - ANS Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion. Egress - ANS A means of exit from a fire or other emergency. Single Action fire alarm pull station - ANS requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors. Double Action fire alarm pull station - ANS Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside. All gas containers and the related equipment - ANS must be protected from extreme temperature and physical damage. Any single standard portable LPG container must not exceed - ANS 100 lbs in weight. Any single CNG container must not exceed - ANS 381 SCF. Permits shall be readily available on the premise for inspection by - ANS Fire Department representatives. NFPA stands for - ANS National Fire Protection Association. Most common fuel gases used in blowtorches are - ANS LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas). A fire guard is responsible for - ANS overseeing torch operations. The pre-hot work check must be conducted by - ANS the responsible person before hot work is authorized and at least once per day. The check reports must be kept at the work site - ANS maintained on the premises for a minimum of 48 hours after work is complete. Exhaust fans - ANS may be used to draw the fumes away from the work area The workers should - ANS wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs