FDNYC G60 Practice Exam With Answers! 100% CORRECT ANSWERS, Exams of Safety and Fire Engineering

FDNYC G60 Practice Exam With Answers! 100% CORRECT ANSWERS FDNYC G60 Practice Exam With Answers! 100% CORRECT ANSWERS

Typology: Exams

2023/2024

Available from 08/28/2024

as-tutor
as-tutor 🇺🇸

4

(6)

350 documents

1 / 7

Toggle sidebar

Related documents


Partial preview of the text

Download FDNYC G60 Practice Exam With Answers! 100% CORRECT ANSWERS and more Exams Safety and Fire Engineering in PDF only on Docsity! FDNYC G60 Practice Exam With Answers Question All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current - Answer Certificate of Fitness Question The Certificate of Fitness holder - Answer must regulate the pressure and flow of oxygen and natural gas to each torch. Question if the torch operator for jewelry manufacture involves - Answer any oxygen with any fuel gas containers, the operator must be a C of F holder. Question A Certificate of Fitness Holder must keep his or her certificate - Answer on their person or otherwise readily available for inspection by any representative of the fire Department Question The easiest way to extinguish a fire caused by a leak is to - Answer close the shutoff valve Question Permits issued by the FDNY are required to conduct the following hot work: - Answer storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. Question For LPG, 400 SCF is - Answer approximately 47 lbs Question the number of LPG containers for the storage, use, handling or transportation, requiring a permit - Answer 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Question Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF - Answer must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Question Site-specific permit - Answer may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only Question A city-wide permit is valid - Answer up to 30 days Question Permits shall be - Answer readily available on the premise for inspection by Fire Department representatives. Question Hot work authorization should be issued by the responsible person, and it - Answer must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete FDNYC G60 Practice Exam With Answers Question FDNY permits - Answer will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities. Question CNG - Answer Compressed Natural Gas. Question For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning. - Answer 48 Question A class A fire extinguisher fights fires from - Answer Paper Question How old must a candidate be in order to earn a Certificate of Fitness? - Answer 18 Years Old Question What type of fire is a Class B fire extinguisher used on? - Answer Oil Question Examples of combustibles include - Answer Newspaper Question An example of a flammable material would be - Answer Gasoline Question Fire extinguishers must be inspected once every - Answer Month Question A work area should be - Answer Well Ventilated Question A type C fire involves - Answer Live electrical equipment Question Automatic sprinkler heads should be - Answer covered by a damp cloth and removed after hot work Question A permit is required for storing a flammable gas in excess of - Answer 400 scf Question Acetylene burns at - Answer 3000 degrees Fahrenheit Question It is dangerous to use fuel gas at pressures above - Answer 15 psi Question A fire extinguisher must be mounted - Answer so that the top is not more than 5 feet off the floor Question To extinguish a fire - Answer Always approach the fire from upwind Question PASS stands for - Answer Pull, Aim, Squeeze, Sweep Question In the case of any fire, - Answer The FDNY must be notified Question For piped gas, - Answer the gas should be shut off first Question Oxygen cylinders are made of - Answer Steel FDNYC G60 Practice Exam With Answers Question A compressed gas container must - Answer Not be rolled on its side. Question An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a - Answer Hot work area. Question Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of - Answer 20 feet. Most fires are the result of - Answer Sparks. Question Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. - Answer 60. Question Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials. - Answer 35. Question If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut. - Answer One hour or more. Question A torch should be ignited by using a - Answer Friction device. Question Why should oil or grease not be used near oxygen? - Answer It might cause an explosion. Question How long is a site permanent specific permit to store flammable gases valid for? - Answer 30 days Question How many Fire Guards are required on a job site that has 3 torches in operation? - Answer One per torch and additional one stationed on the floor below. Question Portable LPG containers greater than ______ must not be stored in residential occupancies. - Answer 16.4 oz. Question An oxygen cylinder may store gas at pressure up to - Answer 2200 psi. Question A Responsible Person is one who is - Answer trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises. Question A designated Hot Work area must be at least_______ feet away from combustible materials. - Answer 35. Question For all Hot Work, inspections must be completed_______ after completion of torch operations. - Answer 30 minutes. Question A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. - Answer 2- A:20-B:C, 30 feet. FDNYC G60 Practice Exam With Answers Question For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. - Answer 3-A: 40-B:C, 30 feet. Question Empty compressed gas cylinders - Answer Should be handled in the same manner as full ones. Question Panic Bar - Answer A device fitted on the inside of a door that would allow a person to push against a door to open it. Question A type of valve typically used in sprinkler systems - Answer OS & Y Valve- Outside Screw and Yoke Valve. Question Fire Drill - Answer A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan. Question shall not be considered a fire - Answer flame used in any lawful, properly operating device, equipment or system or other controlled setting. Question Fire Watch - Answer A temporary measure intended to ensure continuous and systematic surveillance of a building or portion thereof by one or more qualified individuals for the purposes of identifying and controlling fire hazards, detecting early signs of fire, raising an alarm of fire and notifying the department. Question Hot Work - Answer Cutting, welding, thermit welding, brazing, soldering, grinding, thermal spraying, thawing pipe, cad welding, installation of torch-applied system, or any other similar operation or activity. Question Torch Applied Roof-System - Answer Bituminous roofing systems using membranes that are adhered by heating with a torch and melting asphalt back coating instead of mopping hot asphalt for adhesion. Question Egress - Answer A means of exit from a fire or other emergency. Question Single Action fire alarm pull station - Answer requires the user to simply pull a lever or break glass to activate the alarm. This type is commonly used indoors. Question Double Action fire alarm pull station - Answer Double Action fire alarm pull station- requires the user to take two steps in order to activate the alarm such as lifting a cover and then pulling a lever. This type of alarm is commonly used outside. Question All gas containers and the related equipment - Answer must be protected from extreme temperature and physical damage. Question Any single standard portable LPG container must not exceed - Answer 100 lbs in weight. FDNYC G60 Practice Exam With Answers Question Any single CNG container must not exceed - Answer 381 SCF. Question Permits shall be readily available on the premise for inspection by - Answer Fire Department representatives. Question NFPA stands for - Answer National Fire Protection Association. Question Most common fuel gases used in blowtorches are - Answer LPG (e.g. butane, propane), natural gas (methane) (either CNG or piped natural gas). Question A fire guard is responsible for - Answer overseeing torch operations. Question The pre-hot work check must be conducted by - Answer the responsible person before hot work is authorized and at least once per day. Question The check reports must be kept at the work site - Answer maintained on the premises for a minimum of 48 hours after work is complete. Question Exhaust fans - Answer may be used to draw the fumes away from the work area Question The workers should - Answer wear flame resistant gloves and aprons and should not be worm Clothing with pockets or cuffs