Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FDNYC G60 Practice Exam|Questions and Answers| 100% Correct| Latest 2023|Download to Ace y, Exams of Safety and Fire Engineering

FDNYC G60 Practice Exam|Questions and Answers| 100% Correct| Latest 2023|Download to Ace your FDNYC G60 exam All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current Certificate of Fitness The Certificate of Fitness holder must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing

Typology: Exams

2023/2024

Available from 06/21/2024

paul-marks
paul-marks 🇺🇸

3.9

(21)

865 documents

1 / 15

Toggle sidebar

Related documents


Partial preview of the text

Download FDNYC G60 Practice Exam|Questions and Answers| 100% Correct| Latest 2023|Download to Ace y and more Exams Safety and Fire Engineering in PDF only on Docsity! FDNYC G60 Practice Exam|Questions and Answers| 100% Correct| Latest 2023|Download to Ace your FDNYC G60 exam All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current Certificate of Fitness The Certificate of Fitness holder must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit 15 psi A fire extinguisher must be mounted so that the top is not more than 5 feet off the floor To extinguish a fire Always approach the fire from upwind PASS stands for Pull, Aim, Squeeze, Sweep In the case of any fire, The FDNY must be notified For piped gas, the gas should be shut off first Oxygen cylinders are made of Steel A temporary permit to conduct torch operations is valid from 1 day to 12 months A hot work permit is required for welding A spark producing tool requires a Fire Guard Soldering and brazing temperatures are typically 840 degrees Fahrenheit Oxy-Acetylene can generate a temperature of up to 6000 degrees Fahrenheit An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a Hot Work Area A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a Fire Guard Most fires are the result of sparks What should you do if ice buildup occurs on the gas cylinder itself? call 911 immediately If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should take it out of service If a gas container is unmarked, the certificate of fitness holder should take the cylinder out of service What tank condition would be cause to remove it from service? the pressure relief valve shows visible damage A control valve should be opened by hand Persons conducting Torch Operations must possess a current G-60 Certificate of Fitness A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen. A Fire A class B fire extinguisher fights fires from oil A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material Certificate of Fitness What type of fire is a Class A fire extinguisher used on? cardboard An example of a flammable material would be kerosene Fire extinguishers must be maintained by a W-96 Certificate of Fitness holder every year Hot work area. Fuel gas or oxygen containers in storage must be separated from any combustible materials by a minimum distance of 20 feet. Most fires are the result of Sparks. Sparks and pieces of hot metal are the source of ignition in about______ of fires in industrial occupancies. 60. Under no circumstances can hot work be performed within _____ feet of flammable or explosive materials. 35. If torch operation is to be discontinued for a period of ___________, the torch valve must be closed and the gas supply to the torch must be completely shut. One hour or more. A torch should be ignited by using a Friction device. Why should oil or grease not be used near oxygen? It might cause an explosion. How long is a site permanent specific permit to store flammable gases valid for? 30 days How many Fire Guards are required on a job site that has 3 torches in operation? One per torch and additional one stationed on the floor below. Portable LPG containers greater than ______ must not be stored in residential occupancies. 16.4 oz. An oxygen cylinder may store gas at pressure up to 2200 psi. A Responsible Person is one who is trained in the fire safety hazards associated with hot work, and in the necessary and appropriate measures to minimize those hazards, who is designated by the owner of a premises to authorize the performance of hot work at the premises. A designated Hot Work area must be at least_______ feet away from combustible materials. 35. For all Hot Work, inspections must be completed_______ after completion of torch operations. 30 minutes. A minimum ___________ rating Fire Extinguisher must be readily accessible within ________ of the hot work location for torch operations. 2-A:20-B:C, 30 feet. For a Torch-applied Roof System, a minimum ___________ rating Fire Extinguisher must be readily accessible within ________. 3-A: 40-B:C, 30 feet. Empty compressed gas cylinders Should be handled in the same manner as full ones. Panic Bar A device fitted on the inside of a door that would allow a person to push against a door to open it. A type of valve typically used in sprinkler systems OS & Y Valve- Outside Screw and Yoke Valve. Fire Drill A training exercise by which building occupants are familiarized with and/ or practice the procedures for the safe, orderly and expeditious in-building relocation, partial evacuation or evacuation, as applicable to the occupancy or building type, in accordance with the fire safety and evacuation plan. shall not be considered a fire flame used in any lawful, properly operating device, equipment or system or other controlled setting. Fire Watch