Study with the several resources on Docsity
Earn points by helping other students or get them with a premium plan
Prepare for your exams
Study with the several resources on Docsity
Earn points to download
Earn points by helping other students or get them with a premium plan
Community
Ask the community for help and clear up your study doubts
Discover the best universities in your country according to Docsity users
Free resources
Download our free guides on studying techniques, anxiety management strategies, and thesis advice from Docsity tutors
FLORIDA FIRE INSPECTOR PRACTICE EXAM 100% VERIFIED ANSWERS 2024/2025 CORRECT STUDY SETFLORIDA FIRE INSPECTOR PRACTICE EXAM 100% VERIFIED ANSWERS 2024/2025 CORRECT STUDY SET
Typology: Exams
1 / 7
Which of the following is NOT considered to be a model code orgnization? A. National Fire Protection Association B. National Fire Academy C. International Code Counil D. American Society of Mechanical Engineers B. National Fire Academy A prescriptive code does which of the following? A. List the specific details the installation or construction must meet B. Requires equipment to be installed for protection against a hazard C. Is intereted locally D. Is a national standard A. List the specific details the installion or construction must meet What type of tanker typically transport 6,000 to 10,000 gallons of flammable and combustible materials? A. MC-306 Tanker B. MC-307 Tanker
C. MC-312 Tanker D. MC-314 Tanker A. MC-306 Tanker Railway tankers typically transport up to ____ gallons A. 25, B. 30, C. 35, D. 40, B. 30, Which items should be a top priority when evaluating the building's fire protection features? A. Exit doors B. Fire alarm systems and automatic sprinkler systems C. HVAC D. Utility locations v What is the minimum acceptable rating for fire extinguishers? A. 1A10BC B. 2A10BC C. ABCD D. 10A10BC B. 2A10BC A frangible bulb sprinkler head with a temperature rating of 500-575 degrees would be what color? A. Black B. Orange
C. Red D. Green A. Black NFPA ____ is the standard on dry chemical extiguishing systems. A. 17 B. 25 C. 13 D. 55 A. 17 How thick can wood posts in a heavy timber constructed building be? A. 2" B. 4" C. 6" D. 8" D. 8" (20.3cm) NFPA ____ is the standard for fire safety and emergency sysmbols. A. 1 B. 10 C. 101 D. 170 D. 170 How many sleeping accommodations are requires for an occupancy to be classified as a hotel? A. More than 4 B. More than 8 C. More than 12 D. More than 18
C. More than 12 The ____ is that portion of a mess of egress that is between the exit access and exit discharge. A. Occupant load B. Exit C. Stairs D. Exit way B. Exit Which process does the permit application process often mirror? A. Preplan activities B. Construction site visits C. Fire company orientation training D. Plan review D. Plan review With the trasitional lettering system for portable fire extingusihers, what shape and color would signify a Class A fire? A. Red square B. Red circle C. Green Triangle D. Blue circle C. Green triangle Which of the following classifications of flammable and combustible liquids have a flashpoint higher than 140? A. Class I B. Class II C. Class III D. Class IV
C. Class III What is the unit of electrical pressure represented by the letter "E"? A. Volt B. Watt C. Amp D. Ohm A. Volt What is the minimum number of exits for an occupant load of 1,000 or more people? A. 4 B. 5 C. 6 D. 7 A. 4 When a generator supplies back-up power to emergency lighting, a delay up to ____ secods is tolerable. A. 0 B. 5 C. 10 D. 15 C. 10 Under NFPA 24, a Class A fire hydrant will be ____. A. Red B. Orange C. Green D. Light blue A. Red
A single sprinler riser can cover ____ square feet for light and ordinary hazard occupanies. A. 52, B. 58, C. 62, D. 68, A. 52, One of the things that a Fire Inspector II could be expected to do that a Fire Inspector I would not is to: A. Investigate complaints B. Process a permit application C. Conduct basic fire inspection D. Apply codes and standards B. Process a permit application What are the four phase of fire development in their correct orders? A. Ignition, decay, fully developed, growth B. Ignition, fully developed, growth, decay C. Decay, fully developed, growth, ignition D. Igintion, growth, fully developed, decay D. Ignition. growth, fully developed, decay What is the correct name for NFPA 101? A. Uniform fire code B. Occupancy class code C. Life safety code D. Occupancy safety code C. Life safety code
An ordinary dry-chemical extinguisher is rated for which class of fire? A. A and C B. A,B, and C C. B and C D. C and D C. B and C The minimum separation distance for 50 or more pallets is ____ feet from buildings. A. 15 B. 20 C. 25 D. 30 v