Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

FOA CFOT CERTIFICATION EXAM 2024 NEWEST ACTUAL EXAM COMPLETE 100 QUESTIONS WITH DETAILED, Exams of Nursing

FOA CFOT CERTIFICATION EXAM 2024 NEWEST ACTUAL EXAM COMPLETE 100 QUESTIONS WITH DETAILED VERIFIED ANSWERS ALREADY GRADED A+ BRAND NEW!!

Typology: Exams

2024/2025

Available from 11/12/2024

Examiner2025
Examiner2025 🇺🇸

5

(1)

2.9K documents

1 / 18

Toggle sidebar

Related documents


Partial preview of the text

Download FOA CFOT CERTIFICATION EXAM 2024 NEWEST ACTUAL EXAM COMPLETE 100 QUESTIONS WITH DETAILED and more Exams Nursing in PDF only on Docsity!

FOA CFOT CERTIFICATION EXAM 2024 NEWEST ACTUAL EXAM COMPLETE 100 QUESTIONS WITH DETAILED VERIFIED ANSWERS ALREADY GRADED A+ BRAND NEW!! The proper method of pulling optical fiber cables is to attach the pull wire or tape to the ____ of the cable. - CORRECT ANSWER >>>>Strength members According to the references, hybrid cables are cables that contain ____. - CORRECT ANSWER

Both singelmode and multimode optical fibers What type of fiber cable design allows for large numbers of fibers with ultra-high density, small

size (diameter) and lower cost? - CORRECT ANSWER >>>>ribbon According to the references, composite cables refer to cables that contain ____> - CORRECT ANSWER >>>>both optical fibers and copper conductors Which optical fiber cables must be grounded? - CORRECT ANSWER >>>>all cables that contain metallic elements Fiber optic cable for use inside a building must _______. - CORRECT ANSWER >>>>Be rated to meet the requirements of local building and fire codes Optical fiber cable with a orange colored jacket generally indicates the cable contains _____. - CORRECT ANSWER >>>>Multimode fiber

Premises cable jackets are usually color-coded in what color to indicate singlemode fiber? - CORRECT ANSWER >>>>Yellow Premises cable jackets are usually color-coded in what color to indicate laser-optimized 50/ OM3 or OM4 fiber? - CORRECT ANSWER

Aqua When pulling long lengths of cable in conduit or innerduct, you may need to ____. - CORRECT ANSWER >>>>Any or all of these as appropriate (Pull form the center to the ends, Use a breakaway swivel or monitor tension, Lubricate the cable) In a loose tube cable, a gel or absorbent tape or powder is normally used _____. - CORRECT ANSWER >>>>To prevent water from entering the cable Which type of cable is best suited for indoor installation when fibers ar to be directly

terminated inside a patch panel with adhesive/polish or prepolished splice connectors?

  • CORRECT ANSWER >>>>tight buffer distribution cable What type of cable may require installation of a breakout kit (also called a furcation or fan out kit) for termination? - CORRECT ANSWER >>>>loose tube (loose buffer) cable When pulling cables, the minimum bend radius under tension is generally specified as ______. - CORRECT ANSWER >>>>20 times the cable diameter Cable ties used on fiber optic cables ____. - CORRECT ANSWER >>>>Can harm cables if too tight, so they should be hand-tightened. Fiber optic joints (connectors or splices) should have ____. - CORRECT ANSWER >>>>low loss, minimal reflectance and high mechanical strength

To reduce _____ as well as loss, the end of a connector ferrule is polished to a PC (physical contact) finish. - CORRECT ANSWER

Reflectance Factory terminations, such as used for making patchcords, generally use what method of attaching the connector? - CORRECT ANSWER Epoxy/polish According to the references, the connector in the following list with the best or lowest reflectance would be the ____. - CORRECT ANSWER >>>>SC- APC (Angled Polished Connector) Splices are most often used for _____. - CORRECT ANSWER >>>>A permanent joint between two fibers If you need to permanently join two fibers together with the lowest loss and least amount of reflectance, which of the following should you choose? - CORRECT ANSWER >>>>fusion splice

Mass fusion splicing is normally used on what style of cable? - CORRECT ANSWER >>>>ribbon cable Prior to cable plant acceptance or system turn- up, a(n) _____ is used to measure the cable plant insertion loss to ensure it is within the loss budget. - CORRECT ANSWER >>>>Light source and power meter (LSPM or OLTS) For insertion loss testing, the fiber optic test source must match the _____ of the transmission system or the standards covering the cable plant.

  • CORRECT ANSWER >>>>both fiber type and wavelenght According to the text, it is recommended that reference test cables be chosen for their __________> - CORRECT ANSWER >>>>low loss Which of the following parameters cannot be measured by OTDRs (optical time domain

reflectometers) in fiber optic networks. - CORRECT ANSWER >>>>Transmitter and receiver power For safety, a fiber optic technician or installer should always wear ______ when working with optical fiber. - CORRECT ANSWER >>>>Eye protection During fiber optic installations, the most common danger is caused by ______. - CORRECT ANSWER

Fiber scraps or shards from stripping, cleaving, splicing and termination The link loss budget analysis of a cable plant like the diagram shown is done to _________. - CORRECT ANSWER >>>>All of these choices (Ensure the intended communications system will work on the cable plant system, Provide a pass/fail loss value for comparison to test values, ribbon cable Prior to cable plant acceptance or system turn- up, a(n) _____ is used to measure the cable plant insertion loss to ensure it is within the loss budget. - CORRECT ANSWER >>>>Light source and power meter (LSPM or OLTS) For insertion loss testing, the fiber optic test source must match the _____ of the transmission system or the standards covering the cable plant. - CORRECT ANSWER >>>>both fiber type and wavelenght According to the text, it is recommended that reference test cables be chosen for their __________> - CORRECT ANSWER >>>>low loss Which of the following parameters cannot be measured by OTDRs (optical time domain reflectometers) in fiber optic networks. - CORRECT ANSWER >>>>Transmitter and receiver power For safety, a fiber optic technician or installer should always wear ______ when working with optical fiber. - CORRECT ANSWER >>>>Eye protection During fiber optic installations, the most common danger is caused by ______. - CORRECT ANSWER >>>>Fiber scraps or shards from stripping, cleaving, splicing and termination The link loss budget analysis of a cable plant like the diagram shown is done to _________. - CORRECT ANSWER >>>>All of these choices (Ensure the intended communications system will work on the cable plant system, Provide a pass/fail loss value for comparison to test values, Ensure the cable plant has been properly installed)

A link loss budget should be done for every cable plant installation during the ______ phase of a project. - CORRECT ANSWER >>>>Design The loss of connector on each end of the cable plant ______. - CORRECT ANSWER >>>>Are always included in the loss budget Cladding - CORRECT ANSWER >>>>Material around the center tube (Look at diagram) Core - CORRECT ANSWER >>>>Center tube (Look at diagram) Primary Buffer Coating - CORRECT ANSWER

Material around the core and cladding, it gives the fiber its distinct color (Blue, Red, Agua, etc) Traps light in the core to reduce attenuation - CORRECT ANSWER >>>>Cladding

Is smaller in singlemode than multimode fiber - CORRECT ANSWER >>>>Core Is stripped off for termination or splicing - CORRECT ANSWER >>>>Primary Buffer Coating The outside diameter of this part of the fiber is the same for most singlemode and multimode fibers - CORRECT ANSWER >>>>Cladding Singlemode - CORRECT ANSWER >>>> Multi-mode graded index - CORRECT ANSWER

Multi-mode step index - CORRECT ANSWER >>>> Telecom outside plant - CORRECT ANSWER

Singlemode Telecom FTTx - CORRECT ANSWER Singlemode

CATV hybrid fiber coax network - CORRECT ANSWER >>>>Singlemode LAN fiber to the desk - CORRECT ANSWER

Multimode Graded-Index Consumer digital audio - CORRECT ANSWER Plastic Optical Fiber (POF) Distribution cable - CORRECT ANSWER >>>>Has multiple buffered fiber cables (about 12 individual cables), and it does have strength Design The loss of connector on each end of the cable plant ______. - CORRECT ANSWER >>>>Are always included in the loss budget Cladding - CORRECT ANSWER >>>>Material around the center tube (Look at diagram) Core - CORRECT ANSWER >>>>Center tube (Look at diagram) Primary Buffer Coating - CORRECT ANSWER >>>>Material around the core and cladding, it gives the fiber its distinct color (Blue, Red, Agua, etc) Traps light in the core to reduce attenuation - CORRECT ANSWER >>>>Cladding Is smaller in singlemode than multimode fiber - CORRECT ANSWER >>>>Core Is stripped off for termination or splicing - CORRECT ANSWER >>>>Primary Buffer Coating The outside diameter of this part of the fiber is the same for most singlemode and multimode fibers - CORRECT ANSWER >>>>Cladding Singlemode - CORRECT ANSWER >>>> Multi-mode graded index - CORRECT ANSWER >>>> Multi-mode step index - CORRECT ANSWER >>>> Telecom outside plant - CORRECT ANSWER >>>>Singlemode Telecom FTTx - CORRECT ANSWER >>>>Singlemode CATV hybrid fiber coax network - CORRECT ANSWER >>>>Singlemode LAN fiber to the desk - CORRECT ANSWER >>>>Multimode Graded-Index Consumer digital audio - CORRECT ANSWER >>>>Plastic Optical Fiber (POF) Distribution cable - CORRECT ANSWER >>>>Has multiple buffered fiber cables (about 12 individual cables), and it does have strength members Breakout cable - CORRECT ANSWER >>>>Has multiple simplex cables (about 12 or more Are always included in the loss budget Cladding - CORRECT ANSWER >>>>Material around the center tube (Look at diagram) Core - CORRECT ANSWER >>>>Center tube (Look at diagram) Primary Buffer Coating - CORRECT ANSWER >>>>Material around the core and cladding, it gives the fiber its distinct color (Blue, Red, Agua, etc) Traps light in the core to reduce attenuation - CORRECT ANSWER >>>>Cladding Is smaller in singlemode than multimode fiber - CORRECT ANSWER >>>>Core Is stripped off for termination or splicing - CORRECT ANSWER >>>>Primary Buffer Coating The outside diameter of this part of the fiber is the same for most singlemode and multimode fibers - CORRECT ANSWER >>>>Cladding Singlemode - CORRECT ANSWER >>>> Multi-mode graded index - CORRECT ANSWER >>>> Multi-mode step index - CORRECT ANSWER >>>> Telecom outside plant - CORRECT ANSWER >>>>Singlemode Telecom FTTx - CORRECT ANSWER >>>>Singlemode CATV hybrid fiber coax network - CORRECT ANSWER >>>>Singlemode LAN fiber to the desk - CORRECT ANSWER >>>>Multimode Graded-Index Consumer digital audio - CORRECT ANSWER >>>>Plastic Optical Fiber (POF) Distribution cable - CORRECT ANSWER >>>>Has multiple buffered fiber cables (about 12 individual cables), and it does have strength members Breakout cable - CORRECT ANSWER >>>>Has multiple simplex cables (about 12 or more individual cables), but it does NOT have strength

members Loose Tube cable - CORRECT ANSWER >>>>Has a buffered fiber, strength members and water blocking substance

Zipcord cable - CORRECT ANSWER >>>>Has 2 buffered fibers and strength members Resistance to water damage - CORRECT ANSWER

Gel-filled and blocked cable Can be installed indoors in air handling areas - CORRECT ANSWER >>>>Plenum rated Rodent resistance - CORRECT ANSWER Armored cable Must be more than 20 times cable diameter - CORRECT ANSWER >>>>Minimum recommended bend radius under pulling tension Must be more than 10 times cable diameter - CORRECT ANSWER >>>>Minimum recommended long term bend radius Cladding Singlemode - CORRECT ANSWER >>>> Multi-mode graded index - CORRECT ANSWER >>>> Multi-mode step index - CORRECT ANSWER >>>> Telecom outside plant - CORRECT ANSWER >>>>Singlemode Telecom FTTx - CORRECT ANSWER >>>>Singlemode CATV hybrid fiber coax network - CORRECT ANSWER >>>>Singlemode LAN fiber to the desk - CORRECT ANSWER >>>>Multimode Graded-Index Consumer digital audio - CORRECT ANSWER >>>>Plastic Optical Fiber (POF) Distribution cable - CORRECT ANSWER >>>>Has multiple buffered fiber cables (about 12 individual cables), and it does have strength members Breakout cable - CORRECT ANSWER >>>>Has multiple simplex cables (about 12 or more individual cables), but it does NOT have strength members Loose Tube cable - CORRECT ANSWER >>>>Has a buffered fiber, strength members and water blocking substance Zipcord cable - CORRECT ANSWER >>>>Has 2 buffered fibers and strength members Resistance to water damage - CORRECT ANSWER >>>>Gel-filled and blocked cable Can be installed indoors in air handling areas - CORRECT ANSWER >>>>Plenum rated Rodent resistance - CORRECT ANSWER >>>>Armored cable Must be more than 20 times cable diameter - CORRECT ANSWER >>>>Minimum recommended bend radius under pulling tension Must be more than 10 times cable diameter - CORRECT ANSWER >>>>Minimum recommended long term bend radius INDOOR, short, dry conduit runs, risers and plenums terminated inside junction boxes - Multi-mode step index - CORRECT ANSWER >>>> Telecom outside plant - CORRECT ANSWER >>>>Singlemode Telecom FTTx - CORRECT ANSWER >>>>Singlemode CATV hybrid fiber coax network - CORRECT ANSWER >>>>Singlemode LAN fiber to the desk - CORRECT ANSWER >>>>Multimode Graded-Index Consumer digital audio - CORRECT ANSWER >>>>Plastic Optical Fiber (POF) Distribution cable - CORRECT ANSWER >>>>Has multiple buffered fiber cables (about 12 individual cables), and it does have strength members Breakout cable - CORRECT ANSWER >>>>Has multiple simplex cables (about 12 or more individual cables), but it does NOT have strength members Loose Tube cable - CORRECT ANSWER >>>>Has a buffered fiber, strength members and water blocking substance Zipcord cable - CORRECT ANSWER >>>>Has 2 buffered fibers and strength members Resistance to water damage - CORRECT ANSWER >>>>Gel-filled and blocked cable Can be installed indoors in air handling areas - CORRECT ANSWER >>>>Plenum rated Rodent resistance - CORRECT ANSWER >>>>Armored cable Must be more than 20 times cable diameter - CORRECT ANSWER >>>>Minimum recommended bend radius under pulling tension Must be more than 10 times cable diameter - CORRECT ANSWER >>>>Minimum recommended long term bend radius INDOOR, short, dry conduit runs, risers and plenums terminated inside junction boxes - CORRECT ANSWER >>>>Distribution cable

High fiber count in small diameter for metro or long distance - CORRECT ANSWER >>>>Ribbon cable Patch cords and backplanes - CORRECT ANSWER

Simplex and zip cord tight buffer Ideal for outside plant trunk applications inside innerduct or conduit - CORRECT ANSWER Loose tube (buffer) gel-filled Building cable for conduit, riser and plenum runs without requiring junction boxes - CORRECT ANSWER >>>>Breakout cable Direct buried outside plant - CORRECT ANSWER Armored loose tube cable ST - CORRECT ANSWER >>>> SC - CORRECT ANSWER >>>>

LC - CORRECT ANSWER >>>>

MTP - CORRECT ANSWER >>>>

Insertion loss (Which Tool(s) do you use?) - CORRECT ANSWER >>>>Light source and power meter Continuity, fiber or cable tracing, duplex connector polarity (Which Tool(s) do you use?) - CORRECT ANSWER >>>>Visual fiber tracer Source or receiver power (Which Tool(s) do you use?) - CORRECT ANSWER >>>>Fiber optic power meter Connector faults (scratches, polish, dirt) (Which Tool(s) do you use?) - CORRECT ANSWER

Inspection microscope Fault location, splice loss, length (Which Tool(s) do you use?) - CORRECT ANSWER >>>>OTDR

Continuity, fiber tracing, fault location close to end of a cable (Which Tool(s) do you use?) - CORRECT ANSWER >>>>Visual fault locator Cable to test - CORRECT ANSWER >>>>Cable in the middle wrapped multiple times in circles Connector mating adapter - CORRECT ANSWER

Device that connect two wires together Launch cable - CORRECT ANSWER >>>>Cable connected to the light source Light source - CORRECT ANSWER >>>>Device at the end shining a light or laser Power meter - CORRECT ANSWER >>>>Device taking measurements and giving out numbers Receive cable - CORRECT ANSWER >>>>Cable connected to the power meter

Connector, showing loss and back reflection - CORRECT ANSWER >>>>High spike (upside down V) in the middle of the graph Distance scale - CORRECT ANSWER >>>>On the graph it will be X-axis (left to right) on the bottom side End of the fiber - CORRECT ANSWER >>>>Zig-Zag lines at the end of the graph Initial pulse and dead zone - CORRECT ANSWER

High spike of energy (upside down U) at the beginning of the graph Loss scale - CORRECT ANSWER >>>>On the graph it will be the Y-axis (up and down) on the left side Splice loss - CORRECT ANSWER >>>>A drop of energy (like a step) in the middle of the graph Fiber Size - CORRECT ANSWER >>>>um (microns)

Wavelength - CORRECT ANSWER >>>>nm (nanometers) Bandwidth - CORRECT ANSWER >>>>MHz or GHz (megahertz or gigahertz) Loss - CORRECT ANSWER >>>>dB (decibels) Absolute power - CORRECT ANSWER >>>>dBm (decibels per milliwatts) Cable jacket outside diameter - CORRECT ANSWER >>>>mm or in (millimeters or inches) Cable Length - CORRECT ANSWER >>>>ft or m (feet or meters) A fiber optic inspection microscope can increase the danger of high powered light sources by focusing the light coming out of a fiber into your eye. True or False? - CORRECT ANSWER >>>>True

A fiber optic power meter measures absolute power in dBM (dB referenced to 1 mw) and, when used with a light source, can measure insertion loss expressed in dB. True or False? - CORRECT ANSWER >>>>True When we say 62.5/125 fiber, what does "62.5" mean? - CORRECT ANSWER >>>>core size, the diameter in microns When we say 50/125 fiber, what does "125" mean? - CORRECT ANSWER >>>>cladding size, the diameter in microns OM3 and OM4 multimode fiber with a 50/ micron core are now a popular option in premises cabling systems because they _____. - CORRECT ANSWER >>>>Are "laser optimized" which gives more distance capability with gigabit networks using laser sources

In-multimode fiber, the attenuation (reduction in optical power) of the fiber is _____ at 850 nm than at 1300 nm. - CORRECT ANSWER >>>>Higher Which of the following represents a singlemode (smaller core size) fiber size? - CORRECT ANSWER

9/125 micron Singlemode fiber has _____ bandwidth than multimode fiber. - CORRECT ANSWER greater Most plastic optical fibers are _____. - CORRECT ANSWER >>>>large core step-index When you strip singlemode or graded index multimode mode glass fiber, you are removing the ____. - CORRECT ANSWER >>>>Primary buffer coating