Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

IDPX Practice Test | 85 Questions with 100% Correct Answers | Verified | Updated 2024, Exams of Advanced Education

IDPX Practice Test | 85 Questions with 100% Correct Answers | Verified | Updated 2024 What is the MOST important reason to include expert experiential knowledge from an architectural consultant firm? A-They provide experimental data on research studies B-They bring project-based observations and insights C-They have access to a network of professionals D-They have access to a database of resources B- They bring project-based observations and insights. Which of the following is an advantage of the full wall schedule technique over other scheduling techniques? A-Bar charts are simple to make and understand and are suitable for all project sizes. B-Each activity is given a starting and finishing date, and overlaps are indicated by overlapping bars for each activity. C-This schedule graphically depicts all the tasks required required to complete a project, the sequence in which they must occur, their duration, the earliest or latest possible starting time, and the earliest or latest

Typology: Exams

2023/2024

Available from 06/27/2024

professoraxel
professoraxel 🇺🇸

3.7

(26)

9.1K documents

1 / 22

Toggle sidebar

Related documents


Partial preview of the text

Download IDPX Practice Test | 85 Questions with 100% Correct Answers | Verified | Updated 2024 and more Exams Advanced Education in PDF only on Docsity! IDPX Practice Test | 85 Questions with 100% Correct Answers | Verified | Updated 2024 What is the MOST important reason to include expert experiential knowledge from an architectural consultant firm? A-They provide experimental data on research studies B-They bring project-based observations and insights C-They have access to a network of professionals D-They have access to a database of resources B- They bring project-based observations and insights. Which of the following is an advantage of the full wall schedule technique over other scheduling techniques? A-Bar charts are simple to make and understand and are suitable for all project sizes. B-Each activity is given a starting and finishing date, and overlaps are indicated by overlapping bars for each activity. C-This schedule graphically depicts all the tasks required required to complete a project, the sequence in which they must occur, their duration, the earliest or latest possible starting time, and the earliest or latest possible finishing time. D-This schedule serves as a starting point for discussion among everyone on the project team and becomes a collaborative, interactive exercise until an agreement is reached. pg. 1 professoraxe l D-This schedule serves as a starting point for discussion among everyone on the project team and becomes a collaborative, interactive exercise until an agreement is reached. What are the differences between GANNT/BAR CHART, CPM CHART (critical path method), and FULL WALL SCHEDULE? The Gantt or bar chart is simple to make and understand. In this method each activity is given a starting and finishing date and overlaps in the activity timeframe are illustrated by the overlapping bars. A CPM or Critical Path Method chart depicts all the tasks required required to complete a project, the sequence in which they must occur, their duration, the earliest or latest possible starting time, and the earliest or latest possible finishing time. A full wall schedule involves all members of the design and construction team, including the client, to create an interactive and collaborative schedule that all members can adjust as needed until all parties are in agreement. At that point, the schedule can then be copied down to a smaller format and shared by all members of the team. The project manager is involved in the initial determination of the scope of work and estimation of fees. Which of the following is not under the project manager's responsibility during this phase? pg. 2 professoraxe l C-sole proprietorship D-an LLC or LLP D-an LLC or LLP The main advantage of an LLC or LLP is that liability is limited to a member's investment, a member has no personal liability. In addition, they are easier than corporations to set up and operate. What type of drawing satisfies the requirements of either design intent, constraints, function or constructability? A-shop drawings B-section C-RCP D-detail drawing D-detail drawing satisfies the the requirements in the four categories of design intent, constraints, function and constructability Under what circumstances does the owner have to provide the contractor with evidence of the owner's financial resources to complete the project according to the AIA General Conditions of the Contract for Construction? A-whenever the contractor asks for such evidence B-if the project is a public project pg. 5 professoraxe l C-the owner does not have to offer any such proof D-on request of the contractor if the job is being competitively bid A-whenever the contractor asks for such evidence The General Conditions clearly state the contractor may ask for such evidence. In working with an electrical engineer on a project, what information would the designer most likely put on the interior design power plan? A-conduit sizing B-dedicated outlets C-speaker locations D-switch locations D-switch locations Interior designer coordinates switch locations with furniture placements which makes this the best answer. Speakers locations would be shown on the RCP. In a larger set of construction drawings, which drawing number would indicate a plumbing drawing? A-E2 B-FP2 pg. 6 professoraxe l C-A2 D-M2 D-M2 Plumbing is typically included in the M (mechanical) series. In the master specification format, what division would you classify decorative exterior handrails under? Decorative exterior handrails would be classified under division 05- metals. To minimize conflicts in the contract documents, what is the LEAST important action the interior designer can take? A-Make sure terminology in the specifications is the same as in the drawings. B-Show only dimensions on the drawings. C-Have someone check the drawings before they are issued. D-Write the specifications after the drawings are essentially complete. D-Write the specifications after the drawings are essentially complete. The specifications should be outlined and begun while the drawings are being done. The specifications writer and the job captain should be in constant pg. 7 professoraxe l C-48" (1200 mm) D-54" (1372 mm) C-48" In an assembly occupancy, when are two egress doors are required? A-when the occupancy load is more than 50 and the travel distance to egress exceeds 75 feet B-when the occupancy load is more than 75 and the travel distance to egress exceeds 100 feet C-when the occupancy load is more than 100 and the travel distance to egress exceeds 250 feet D-when the occupancy load is more than 20 and the travel distance to egress exceeds 50 feet A-when the occupancy load is more than 50 and the travel distance to egress exceeds 75 feet What is the efficiency factor of a single leased space? A-the space required to accommodate the tenant's specific functions B-the rentable area divided by the useable area C-the amount of floor area needed by one person to function in the space D-the ratio of the net area or net assignable area to the usable area pg. 10 professoraxe l D-the ratio of the net area or net assignable area to the usable area An efficiency factor is simply the mathematical ratio between one area and another. For a single leased space, the interior layout efficiency is the ratio of the net area (or net assignable area) to the usable area. In developing a signage system for a health care clinic, the designer decides that the room identification signs should be mounted perpendicular to the wall near the door to each room. What would be of LEAST concern in the design work? A-the color of the lettering and its background B-whether or not the width of the accessible route was reduced C-the amount the Braille lettering is raised above the surface D-the mounting height to the center of the sign A-the color of the lettering and its background 2010 ADA Standards for Accessible Design, 703 Signs Barrier-free design requires that objects do not protrude into the accessible path in such a way as to present a hazard. In addition, tactile signs must have a minimum 1/32 in raised surface, and accessible routes must not be reduced in width. The following image depicts a tenant Suite (noted as Suite A) that shares a common wall with adjacent tenant suites on either side and a wall with a public corridor. pg. 11 professoraxe l Following BOMA standards, what is the correct method to measure the occupant area for Suite A? From the inside face of the glass, to the centerline of adjacent demising partitions, to the inside tenant face of the partition bordering public corridor The building commissioning of an interior design project seeking LEED credit is the responsibility of the A-architect B-independent commissioning team C-project's mechanical engineer D-project's interior designer B-independent commissioning team To get LEED credit, an independent commissioning team must be used. Even without seeking LEED credit, commissioning requires a joint effort of the engineer, the contractor, the electrical engineer, the building owner, and others. Which does not happen during project close-out? A-respond to owner's questions and problems during "shakedown" period immediately after move-in B-verify that all operating instructions, guarantees, maintenance procedures are forwarded to client C-verify correction of punch list items D-assist with move-in as outlined in agreement pg. 12 professoraxe l the owner and the contractor. Contracts between the owner and the contractor are established in one of two ways. With a negotiated contract, the owner (with the possible assistance of the interior designer) selects a contractor to do the work. The contractor and owner then negotiate a price and other terms of their agreement. The contractor may be selected based on a previous working relationship, on the recommendations of others, or both. Negotiation is discussed later in this chapter. With a bid contract (or tendered contract, in Canada), the drawings and specifications are completed by the interior designer (and other consultants, if necessary) and then sent to several general contractors who bid on the work defined by the contract documents. The owner (again, with the assistance of the interior designer) can then select the contractor based on cost as well as experience, schedule, and other criteria. All of the following are true about pivot door hinges EXCEPT? makes it easy to seal the door against sound or light transmission Because of the way they operate center pivots cannot be used with a doorstop on the same side of the door on both jambs. This makes it difficult to seal the door against sound or light transmission on the hinge and strike sides. pg. 15 professoraxe l All of the following are true about hollow metal doors EXCEPT? are seldom used for commercial construction Metal doors and frames referred to as hollow metal are seldom used for interior residential construction, although they may be used for an exterior door. They are, however, frequently used in commercial construction because of their durability, security and fire-resistive qualities. All of the following are true about wood structural systems EXCEPT? typically not used in residential construction Structural systems for single family residential construction and small commercial construction typically use wood and wood products as the primary materials. Wood is one of the oldest and most common structural materials. It is plentiful, inexpensive, relatively strong in both compression and tension, and easy to work with and fasten. Which would you use to separate a building into two different construction types? pg. 16 professoraxe l A-Fire barrier B-Fire partition C-Firewall D-2 hour fire rated partition C-Firewall According to the IBC, any wall located on a lot line between adjacent buildings, which is used or adapted for joint service between the two buildings, is a party wall and shall be constructed as a fire wall in accordance with Section 706. Fire partitions and fire barriers are used within a building of one construction type. A two hour fire rated partition is a type of fire partition. Source: IBC 706.1.1 Party Walls Which statement is most true about an acoustical ceiling system: A-the ceiling will not prevent any meaningful transmission of sound B-the ceiling will reflect the sound back into the room, improving its acoustic qualities C-the ceiling will prevent sound transmission from one room to adjacent rooms pg. 17 professoraxe l B-when ordering furniture for a client C-when placing the order for custom window treatments D-when ordering stock wall covering A-all of these Designers who order from any type of supplier or vendor commonly are required to pay part or all of the price for goods and services up front, at the time the order is placed. Interior designers who have not established credit with suppliers require some prepayment from their clients. Prepayments are an important way for the interior designer to determine if the client is really serious about continuing with the project. An Interior Designer is working on the design for new hospital. Which of the following fabrics would be the BEST choice to use as an upholstery fabric for soft seating in a patient waiting area? D - UPHOLSTERY FABRIC 'D' Characteristics: Abrasion: 100,000 double rubs Content: 52% Polyester, 31% Post-Industrial Recycled Polyester, 17% Post-Consumer Recycled Polyester Finish: Crypton Backing: Crypton Weight: 23.1 oz/ly (716 gr/lm) Crypton has BOTH antimicrobial and stain resistant properties, pg. 20 professoraxe l and is also impermeable. At 100,000 double rubs, its durability is also suitable for a hospital application. You are selecting flooring for a large locker room in a gym renovation on a university campus. Which standard test method is most important to verify prior to finalizing your selection to ensure that the material is appropriate for the application? ASTM F462, Standard Consumer Safety Specification for Slip- Resistant Bathing Facilities. This test is used with soapy water for bathtubs and shower structures. Which of the following is not part of interior design delivery service? A-simple assembly of goods B-removal of all cartoning and packaging materials C-checking in the merchandise at the local warehouse from the freight company truck and inspecting items for damage D-installation D-installation Although the two terms may seem like the same thing, in reality they are not. Delivery means taking the tangible goods to the job site and placing them in their correct location. Installation means that some additional services are involved in the delivery process, such as assembly or construction of the products. pg. 21 professoraxe l An area rug is delivered to the site and placed where the interior designer has specified. Wall to wall carpet must be installed to complete the job. Application for payment vs invoice? application for payment = from a contractor (GC) invoice = from a vendor (think FF&E) pg. 22 professoraxe l