IEC YEAR 2 FINAL EXAM 2025 NEWEST ACTUAL EXAM COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+
Typology: Exams
1 / 15
For the purpose of determining the number of current- carrying conductors in a cable or conduit, the neutral _____ counted when the branch circuit is 120/240-volt, 1 phase, 3 wire connected to a 120/240-volt, 3 phase delta, 4 wire panelboard. Each of the two circuits carries 16 amps and serves resistive (linear) loads. Correct Answer is not Where a 120/240 volt, 1 phase, 3 wire multiwire branch circuit is connected to a "split-wired" duplex receptacle in a barber shop, the branch-circuit OCPD/disconnect is permitted to be ______ i. two single-pole circuit breakers without handle ties ii. two single-pole circuit breakers with identified handle ties iii. a 2-pole circuit breaker Correct Answer ii or iii only Which of the following is a type of circuit condition? i.short circuit ii. overload Correct Answer i and ii
A 20-amp multiwire branch circuit is connected to breakers 1 and 3 in a 120/208 volt 3 phase 4 wire panelboard. _____ if the "hot" from breaker 3 and the neutral are connected to a 2000-watt lighting fixture load. Correct Answer The load will operate normally and the breaker will not trip When ____ touch together this is a short circuit.
electrodes could you use? Correct Answer 10 ft of trade size 1 rigid metal conduit Your only available grounding electroe is the metal underground water pipe from the water utility. You are required by the NEC to have one other grounding electrode for your service. You could use which of the following driven electrodes?
(one) 12/2 with ground AC cable (BX) with exterior connector The shallowest switch box you can use for this installation is 3"x 2"x _______." Correct Answer 2 1/ When spray application equipment cannot be operated unless the exhaust ventilation system is operating and functioning properly and spray application is automatically stopped if the exhaust ventilation system fails the system is said to be ______. Correct Answer interlocked Vertically- mounted SPDT swithces shall be ON when in the ______ position.
In a 3 phase panelboard that has vertical busbars that are stacked back-to-front, the B phase feeder conductor is connected to the ___ busbar. Correct Answer middle The maximum length of a flexible cord used to connect data-processing equipment to a branch circuit outlet box is _______. Correct Answer 4.5 meters The "J" designation in any of the "S-type" flexible cords designates _____. Correct Answer a junior size A certain piece of equipment is to be connected with SOO flexible cord. The equipment requires 2 ungrounded and 1 grounded conductors. Whati si the smallest AWG size cord that can be used to connect the equipment? All conductors should be counted as a current carrying. The maximum load on any one conductors is 31 amps. The equipment will operate continuously. Correct Answer 6 The Ampacity of each conductor of a 8/3 AWG multiconductor Type W flexible cable used to supply fastened-in-plalce utilization equipment is ______ amps. See NEC T. 400.4 for available sizes. One of the conductors is an EGC and all conductors have a 75C insulation rating. Correct Answer 65 An electric-discharge luminaire utilizes a ____ for the operation of the lamp. Correct Answer ballast ______ shall not support luminairs weighing over 6 lb. Correct Answer lampholder
The smallest circuit breaker that can be installed in a panel is ____ amp. The circuit supplies power to a 240- volt, single-phase, 5.8 KW, 50-gallon water heater. Correct Answer 30 A 100-gallon water heater is to be installed to supply hot water to the restrooms in an office building. The water heater is rated for 9.8 KW at 240 volts 1- phase. The minimum size THHN/THWN copper wire that can be installed between the required disconnect switch and the water heater is _____ AWG. Correct Answer 6 A unit switch is the ON/OFF switch on an appliance that disconnects all ____ conductors. Correct Answer ungrounded A magnetic field is made up of invisible lines of force called ______ Correct Answer magnetic flux Where operating in the United States, AC voltage reaches a negative peak _____ times during one second. Correct Answer 60 Which of the conversion formulas listed below is correct? RMS= Peak x. RMS= Peak x 1.414 Correct Answer RMS= Peak x. Which of the conversion formulas listed below is correct? Peak = RMS x 1. Peak= RMS/1.414 Correct Answer Peak= RMS x 1.
The unit of measure for capacitance is ______. Correct Answer Farads When a resistive AC circuit also contains inductance and/or capacitance, the total opposition to current flow is called ______. Correct Answer impedance In a 60 Hz circuit, containing a 12 uf capacitor, the capacitive reactance is ____ ohms. Correct Answer
In a circuit with 25 ohms resistance and 50 ohms capacitive reactance, the impedance is ______ ohms. Correct Answer 55. At a recreational vehicle park, electrical service feeders shall be calculated on basis of not less than 600 volt- amperes per site when equipped with _________. Correct Answer 20a supply facilties with only one dedicated tent site In an AC circuit the total opposition to current flow is referred to as ______. Correct Answer Impedance (z) True power is measure in ______ Correct Answer watts _______ surrounds the windings in typical "pole-mounted" transformers. Correct Answer oil
In reality, transformer efficiency can never be 100% because of ______.
connected to the primary originates from a 2-pole circuit breaker in a 277/480 volt 3 phase 4 wire panelboard. The current measure in one of the circuit conductors connected tot he breaker is 15.9 amps. The efficiency of this transformer is _______ % Correct Answer 96. ______ in utility transmission lines reduces the power losses in the transmission conductors. Correct Answer increasing the voltage Temperature _____ is the difference in temperature between the transformer windings and the ambient temperature surrounding the transformer. Correct Answer rise 40C = ____ F Correct Answer 104 When a transformer is loaded beyond its rating the effects in the transformer are ______
small transformers have compensation built into their secondaries. Higher/lower Correct Answer higher You need to change from 240 volts to 480 volts to operate a piece of equipment that will require 25 KVA at 480 volts. You must use a transformer that is built specifically for step-up applications. T/F Correct Answer false A square D transformer with a nameplate rating of 240/480- V primary and 120/240 volt secondary can be connected to a 2-pole breaker in a _______ panelboard and deliver nameplate-rated voltage to a load.
Demand Factor is defined as ______ Correct Answer The ratio of the maximum demand of a system, or part of a system, to the total connected load of a system or the part of the system under consideration The ______ rating is the ampere rating or setting of the over current device protecting the conductors. Correct Answer branch circuit General lighting loads for dwelling units are calculated at ______ VA per square foot. Correct Answer 3 Article 220 required that each single or multiple receptacle on a single strap be calculated at ______ VA Correct Answer 180 For a single-family dwelling with six appliance loads, demand factors may be applied to ______ of these loads using the standard calculation. Correct Answer all six Using the standard calculation, the total load for household clothes dryers is computed at ______ VA or the nameplate rating whichever is higher. Correct Answer 5000 Using the standard calculation, the demand load for house hold electric ranges rated in excess of _____ kW is computed per NEC Table 220.55 Correct Answer 1 3/
For dwellings, heating or A/C loads are calculated at ______ of the nameplate rating and the largest load is used for a standard calculation. Correct Answer 100 The feeder neutral load is the maximum unbalance between ______.
conduit with other circuits? Correct Answer it can share a neutral with another circuit Equipment designed to open circuits under ____ shall have an interrupting rating not less than the nominal circuit voltage and the current that is available at the line side of the equipment.
Which of the following THHN/THWN conductors is the smallest size permitted for the feeder? Correct Answer 3/ The maximum number of 3-pole circuit breakers used as service disconnects permitted in a 3 phase panelboard is ______. Correct Answer 6 Which of the following are characteristics of THHN/THWN insulation?