IRC 2018 Exam with COMPLETE SOLUTION | Questions with 100% Correct Answers.., Exams of Community Corrections

IRC 2018 Exam with COMPLETE SOLUTION | Questions with 100% Correct Answers.. Flexible cords for kitchen range hoods shall be _______________ inches minimum and _____________ inches maximum length. - CORRECT ANSWERS--18/48 Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not smaller than No. ______________ AWG. - CORRECT ANSWERS--12 Electrical services within the scope of the IRC are limited to ____________-volt, 0-to _______________ - ampere, single-phase systems. - CORRECT ANSWERS- 120/240 400 The markings for identification of disconnecting means shall have the durability to withstand the Involved. - CORRECT ANSWERS--Enviroment Electrical panel boards and over current devices shall not be located in. . - CORRECT ANSWERS--Clothes closets, bathrooms or over the steps of a stairway.

Typology: Exams

2023/2024

Available from 09/09/2024

NurseTakshif
NurseTakshif 🇬🇧

928 documents

1 / 2

Toggle sidebar

Related documents


Partial preview of the text

Download IRC 2018 Exam with COMPLETE SOLUTION | Questions with 100% Correct Answers.. and more Exams Community Corrections in PDF only on Docsity! IRC 2018 Exam with COMPLETE SOLUTION | Questions with 100% Correct Answers.. Flexible cords for kitchen range hoods shall be _______________ inches minimum and _____________ inches maximum length. - CORRECT ANSWERS--18/48 Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not smaller than No. ______________ AWG. - CORRECT ANSWERS--12 Electrical services within the scope of the IRC are limited to ____________-volt, 0-to _______________ - ampere, single-phase systems. - CORRECT ANSWERS-- 120/240 400 The markings for identification of disconnecting means shall have the durability to withstand the Involved. - CORRECT ANSWERS--Enviroment Electrical panel boards and over current devices shall not be located in. . - CORRECT ANSWERS--Clothes closets, bathrooms or over the steps of a stairway. Interior metal water piping located more than ______ feet from the point of entrance to the building shall not be used as part of the grounding electrode system. - CORRECT ANSWERS--5 Above-ground service-entrance cables subject to physical damage shall be protected by Schedule ____________ PVC conduit. - CORRECT ANSWERS--80 In no case shall the point of the attachment for service-drop conductors be less than. Feet above finished grade. - CORRECT ANSWERS--10 Overhead service-drop conductors shall have a vertical clearance of not less than __________ feet above the roof surface. - CORRECT ANSWERS--8 Over residential property and driveways, service-drop conductors shall have __________ feet minimum clearance above final grade. - CORRECT ANSWERS-- 12 Connected to establish electrical continuity and conductivity. - CORRECT ANSWERS--Bonded (Bonding) The rating of any one cored-and-plug-connected utilization equipment shall not exceed. Percent of the branch-circuit ampere rating. - CORRECT ANSWERS--80 Branch circuit ratings for space heating and water heating appliances shall be considered Loads. - CORRECT ANSWERS--Continuos