Medical Gas Refresher Exam Questions and Answers, Exams of Advanced Education

A comprehensive set of exam questions and answers related to medical gas systems, including topics such as positive pressure supply systems, outdoor enclosures, piping labeling, oxygen usage, vacuum filtration, instrument air systems, cryogenic fluid systems, and more. The questions cover a wide range of technical details and code requirements specified in nfpa 99, the health care facilities code. This document could be useful for healthcare professionals, facility managers, and students studying medical gas systems to prepare for exams, review course material, or stay up-to-date with the latest industry standards and best practices.

Typology: Exams

2023/2024

Available from 07/22/2024

examguide
examguide 🇺🇸

4.7

(21)

6.3K documents

1 / 4

Toggle sidebar

Related documents


Partial preview of the text

Download Medical Gas Refresher Exam Questions and Answers and more Exams Advanced Education in PDF only on Docsity! Med gas Refresher Exam Questions and Answers For positive pressure supply systems, control mechanisms peak calculated demand A) 50% B) 100% C) 150% D) 250%C) 150% D) 250% - Answer- B) 100% 5.1.3.5.5.1(2) The minimum number of exits for outdoor enclosures on bulk cryogenic liquid systems A) 1 B) 2 C) 3 D) 4 - Answer- B) 2 5.1.3.3.2(5) When system gas is used for testing, it shall be tested at ? A) Most remote outlet B) Closest Outlet C) Equipment D) Before Tie in - Answer- C) Equipment 5.1.12.4.8.3 When is the initial pressure test conducted A) After blowdown of distribution piping B) After installation of outlet/inlet rough-in assemblies C) Prior to installation of components that would be damaged by test pressure D) All of the above - Answer- D) All of the above 5.1.12.2.3.2 Inlets/Outlets shall be identified with name of gas or vacuum A) TRUE B) FALSE - Answer- A) TRUE 5.1.5.5 5.1.11.3 ASSE CERTIFICATION FOR INSTALLERS A) 6030 B) 6020 C) 6010 D) 6040 - Answer- C) 6010 2.3.4 PIPING SHALL BE LABELED BY STENCILING OR ADHESIVE MARKERS AND SHALL A) EVERY 20 FEET B) AT LEAST 1 TIME IN EVERY ROOM C) AT LEAST 1 TIME EVERY STORY D) ALL THE ABOVE - Answer- D) ALL THE ABOVE 5.1.11.1 OUTSIDE CENTRAL SUPPLY STORAGE GREATER THAN 200 SQ FT SHALL HAVE A) LOCKABLE DOORS OR GATES B) CONSTRUCTED WITH NONCOMBUSTIBLE MATERIAL C) PROVIDED WITH A MINIMUM OF 2 ENTRY/EXITS D) SEPARATED FOR THE REST OF THE BUILDING WITH 1 HOUR RATED FIRE WALL - Answer- C) PROVIDED WITH A MINIMUM OF 2 ENTRY/EXITS 5.1.3.3.2 (4) OXYGEN IS NOT PERMITTED FOR A) CALIBRATION OF RESPIRATORY MEDICAL DEVICES B) ANIMAL TESTING C) CALIBRATION OF RESPIRATORY MEDICAL DEVICES - Answer- B) ANIMAL TESTING 5.1.3.6.2 WHAT CATEGORY IS LIKELY TO CAUSE MAJOR INJURY OR DEATH A) 2 B) 1 C) 3 D) 4 - Answer- B) 1 4.1.1 VACUUM FILTRATION SHALL BE PROVIDED WITH THE FOLLOWING A) DUPLEX FOR UNINTERRUPTED FILTER CHANGE B) LOCATED ON SOURCE SIDE OF VACUUM PRODUCER C) FILTERS WITH EFFICIENCY OF .3 AND 99.97% HEPA OR BETTER D) ISOLATION VALVE ON PATIENT SIDE OF EACH FILTER - Answer- A) DUPLEX FOR UNINTERRUPTED FILTER CHANGE 5.1.3.7.4(1) INSTRUMENT AIR RESERVE HEADERS SHALL BE PERMITTED IN THE SAME ROOM AS INSTRUMENT AIR COMPRESSOR A) TRUE B) FALSE - Answer- A) TRUE 5.1.3.3.1.4 UNDER WHICH CONDITION CAN INSTRUMENT AIR RESERVE BE THE SAME ENCLOSURE AS THE COMPRESSOR A) 1 HOUR OF NORMAL OPERATION B) MANDATORY CONNECTION REQUIREMENTS CGA V-1 C) ENTER UPSTREAM OF FINAL LINE FILTERS D) AUTOMATICALLY SERVE SYSTEM IN CASE OF COMPRESSOR FAILURE - Answer- A) 1 HOUR OF NORMAL OPERATION 5.1.13.3.4.6(1)