NATE Air-to-Air Heat Pump Exam with Correct Answers, Exams of Heat and Mass Transfer

An exam or study guide related to nate (north american technician excellence) certification for air-to-air heat pumps. It covers a range of topics, including the function of the reversing valve, defrost systems, balance points, packaged vs. Split units, thermostat operation, and various hvac concepts like sensible and latent heat. The correct answers to multiple-choice questions, making it a valuable resource for technicians preparing for the nate certification exam or students studying hvac systems. The level of detail and technical terminology suggests this document would be most useful for university-level hvac or engineering students, as well as professional hvac technicians seeking certification or continuing education.

Typology: Exams

2024/2025

Available from 10/26/2024

Lectjoshua
Lectjoshua 🇺🇸

5

(2)

3.2K documents

1 / 4

Toggle sidebar

Related documents


Partial preview of the text

Download NATE Air-to-Air Heat Pump Exam with Correct Answers and more Exams Heat and Mass Transfer in PDF only on Docsity!

NATE air to air heat pump 4 heat pumps

Exam with correct answers

The primary function of a reversing valve is to... - correct answer -Switch between heating and cooling A typical 4 way reversing valve has 3 ports on one side of the valve body, and a single port on the opposite side of the valve body. To what is this single port connected? - correct answer -The discharge line Of the three ports on one side of the reversing valve's body, to what is the center port connected? - correct answer -The accumulator If a heat pump system is low on charge, then the reversing valve... - correct answer -Is less likely to slide If a reversing valve is leaking under the side, then... - correct answer -The pressures will equalize Most defrost requirements occur at what outdoor temperature? - correct answer - Between 35 and 45 The ambient temperature sensor for a heat pump's defrost system should be located... - correct answer -In the inlet air stream to the outdoor unit If a heat pump's defrost system is initiated by temperature difference, then as the outdoor coil ices up... - correct answer -The temperature difference increases to initiation If a heat pump's defrost system is initiated by pressure difference, then as the outdoor coil ices up... - correct answer -The pressure difference increases to initiation

Once defrost is initiated, what else usually happens? - correct answer -All of the above: outdoor fan is shut off, the reversing valve is switched to the cooling mode, emergency heat strips are energized The balance point of a heat pump can best be described as... - correct answer -The point at which the building's heat loss equals the heat pump's ability to provide heat The outdoor unit must be located so that... - correct answer -All of the above: roof run off is avoided, defrost water can drain away, is elevated above snow drifts. Packaged heat pumps are... - correct answer -Less expensive than split units The single most important consideration for a packaged heat pump to be mounted on a roof is... - correct answer -Can the roof support the weight of the unit? To avoid noise transmission from a packaged heat pump on a roof... - correct answer -Be sure to install the curb gasket On a typical two stage heat pump thermostat, the first stage brings on the heat pump, and the second stage energizes... - correct answer -The first stage of auxiliary heat If the thermostat's system switch is set to AUTO, then... - correct answer -The system will go into either heating, or cooling as the demand imdicates Why do some thermostats have a "C" terminal on their subbases that must be connected? - correct answer -Both sides of power are required to light the lights and the display The heating anticipator is set... - correct answer -To match the amp draw of the heating circuit An add on heat pump requires the addition of a control that will... - correct answer - Not allow the heat pump and the furnace to operate simultaneously in the heating mode

Why would a low pressure switch be placed in the low side of a heat pump? - correct answer -To sense the loss of a charge Electronic air cleaners... - correct answer -All of the above: improve IAQ, remove air borne contaminants, operate at voltages in excess of 5000 VDC An electronic air cleaner cannot remove... - correct answer -Odors An air cleaner begins to become clogged... - correct answer -It becomes more efficient An untrapped condensate drain line that is located on the inlet side of the blower will... - correct answer -Not allow the water to drain from the pan until the fan shuts off What will mitigate the damages associated with the problems encountered (in question #25 above) with an untrapped condensate drain line that will not allow the water to drain from the pan until the fan shuts off? - correct answer -Float activated switch in the pan drain Sensible heat is... - correct answer -Heat that causes a change in dry bulb temperature Latent heat can be measured using... - correct answer -None of the above: a dry bulb thermometer, a wet bulb thermometer, a hygrometer Sensible heat ratio is... - correct answer -Sensible heat / total heat After using ACCA's manual J to calculate the heat loss and heat gain of a residential structure, you would then use which of the following to choose a heat pump? - correct answer -The heat gain A gage reading of 30 psi equates to... - correct answer -44.7 psia

An evacuation of a split system heat pump is considered complete at... - correct answer -500 microns After the vacuum pump is isolated from the system, the micron gage rises to a level of 7500 microns, and stays there. What does this indicate? - correct answer -There is moisture in the system If the wet bulb and dry bulb temperatures are the same, what does this indicate? - correct answer -100% RH COP is derived by... - correct answer -Heat pump output (Btuh)/input kWh • 3413