(SI) - Correct answer-International System of Units 1 in=. mm - Correct answer-25.4 Approved - Correct answer-Acceptable to the authority having jurisdiction. (AHJ) - Correct answer-Authority Having Jurisdiction O rganization, office or individual responsible for enforcing requirements of a code or standard, or for approving equipment, materials, an installation or procedure. Shall - Correct answer-Indicates a mandatory requirement.
Typology: Exams
1 / 11
(SI) - Correct answer-International System of Units 1 in=. mm - Correct answer-25. Approved - Correct answer-Acceptable to the authority having jurisdiction. (AHJ) - Correct answer-Authority Having Jurisdiction O rganization, office or individual responsible for enforcing requirements of a code or standard, or forapproving equipment, materials, an installation or procedure.
Shall - Correct answer-Indicates a mandatory requirement. Should - Correct answer-Indicates a recommendation or that which is advised but not required. Dry Chemical - Correct answer-A powder composed of very small particles, usually sodium bicarbonate-,potassium bicarbonate-, or ammonium phosphate based with added particulate material supplemented by special treatment to provide resistance to packing, resistance to moisture absorption (caking), andthe proper flow capabilities
Wet Chemical - Correct answer-Normally an aqueous solution of organic or inorganic salts or acombination thereof that forms an extinguishing agent
Clean agent - Correct answer-Electrically nonconducting, volatile, or gaseous fire extinguishant that doesnot leave a residue upon evaporation
Dry Chemical Closed Recovery System - Correct answer-A system that does not introduce foreignmaterial into the agent being recovered and has a means of visually inspecting the recovered agent for contaminants Halogenated Closed Recovery System - Correct answer-A system that provides for the transfer ofhalogenated agents between fire extinguishers, supply containers, and recharge/recovery containers so that none of the halogenated agent escapes to the atmosphere. (ODP) - Correct answer-Ozone Depletion Potential Closed recovery systems for halogenated agents with an ODP of ____________ or greater should belisted for use with that agent - Correct answer-.
High pressure cylinders contain pressure greater than _______ PSI at _______F - Correct answer-500PSI at 70F
Low pressure cylinders containing a service pressure at or below _______ PSI at _______F - Correctanswer-500 PSI at 70F
Dry Powder - Correct answer-Solid materials in powder or granular form designed to extinguish Class Dcombustible metal fires by crusting, smothering, or heat-transferring means
Film-forming foam agents - Correct answer-Aqueous film-forming foam (AFFF) and film-formingfluoroprotein foam (FFFP).
HFC - Correct answer-Hydrofluorocarbon
HCFC - Correct answer-Hydrochlorofluorocarbon Halocarbons - Correct answer-Include HCFC HFC PFC and FIC types of agents and other types ofhalocarbons that are found acceptable under the Environmental Protection Agency Significant New Alternatives policy program FIC - Correct answer-Fluoroiodocarbon PFC - Correct answer-perfluorocarbon Halons - Correct answer-Include Halon 1211 and 1301 and mixtures of the two Halon 1301 - Correct answer-Bromotrifluoromethane Halon 1211 - Correct answer-Bromochlorodifluoromethane Hydrostatic testing - Correct answer-Pressure testing of the extinguisher to verify its strength againstunwanted rupture.
Loaded Stream Charge - Correct answer-A water based extinguishing medium that uses an alkali metalsalt as a freezing point depressant.
Extinguisher service pressure - Correct answer-The normal operating pressure as indicated on thenameplate or cylinder of a fire extinguisher
Factory test pressure - Correct answer-The pressure shown on the nameplate at which a shell wastested at time of manufacture.
wetting agent - Correct answer-A concentrate which, when added to water reduces the surface tensionand increases its ability to penetrate and spread
Water Mist Fire Extinguisher - Correct answer-A fire extinguisher containing "distilled or de-ionized"water and employing a nozzle that discharges the agent in a fine spray
Standard for carbon-dioxide fire extinguishers - Correct answer-ANSI/UI (^154) CAN/ULC-S
Standard for Dry Chemical fire extinguishers - Correct answer-ANSI/UL 209 CAN/ULC-S Standard for Water fire extinguishers - Correct answer-ANSI/UL 626CAN/ULC-S
Standard for Halogenated Agent Hand and Wheeled fire extinguishers - Correct answer-CAN/ULC-S Standard for Water Based (Film-Forming) fire extinguishers - Correct answer-ANSI/UL 8 CAN/ULC-S Standard for Halocarbon Clean Agent fire extinguishers - Correct answer-ANSI/Ul 2129CAN/ULC-S
Each fire extinguisher should be marked with - Correct answer-1. Identification of listing and labelingorganization
Fire extinguishers manufactured prior to ____________ shall not be required to comply with 4.1.2. -Correct answer-January 1 1986
MSDS - Correct answer-Material Safety Data Sheet A fire extinguisher shall have a label, tag, or stencil attached to it and provide what information - Correctanswer-1. Contents product name as it appears on manufactures safety data sheet
Class A fires - Correct answer-Fires involving ordinary combustible materials such as wood, cloth, rubber and plastics.
Class B fires - Correct answer-Fires involving flammable and combustible liquids, oils, greases, tars, oil-based paints, lacquers, and flammable gases.
Class C fires - Correct answer-Involve live electrical equipment Class D Fires - Correct answer-Fires involving combustible metals such as magnesium, titanium,zirconium, sodium, and potassium.
Class K Fires - Correct answer-Fires in cooking appliances that involve combustible cooking media (vegetable or animal oils and fats). The classification of fire extinguishers shall consist of a letter that indicates what? - Correct answer-Theclass of fire on which a fire extinguisher has been found to be effective
Fire extinguishers classified for use on Class A or Class B are required to have a what? - Correct answer-Rating number preceding the classification letter that indicated the relative extinguishing effectiveness
What classes of extinguishers use numerical ratings? - Correct answer-A and B What classes of extinguishers are not required to have numbers preceding the Classification letter? -Correct answer-Class C, D, and K
Use of halon agent fire extinguishers shall be limited to what? - Correct answer-Applications where aclean agent is necessary to extinguish fire efficiently without damaging the equipment or area being protected or where the use of alternative agents can cause a hazard to the personnel in the area Placement of portable fire extinguishers containing halogenated agents shall conform to - Correctanswer-Minimum confined space volume requirement warnings listed on extinguisher nameplate
Wheeled fire extinguishers should be considered when - Correct answer-High hazard areas are presentLimited personnel are present
When limited personnel is available, a fire extinguisher shall have what features? - Correct answer-1.High agent flow rate
Buildings having an occupancy hazard subject to Class B or Class C Fires should have a standardcomplement of Class ______ fires for building protection ________ additional Class B or Class C fire extinguishers - Correct answer-A Plus Selection of fire extinguishers for Pressurized Liquids and Pressurized Gas fires should be made on therecommendations __________ - Correct answer-By the manufacturer of the equipment
Water-Soluble Flammable Liquid Fires are also known as - Correct answer-Polar Solvents _________ and _________ types of extinguishers shall not be used for theprotection of Water-SolubleFlammable Liquid Fires - Correct answer-AFFF FFFP
Class K Fire extinguishers manufactured after January 1, 2002 shall not be equipped with - Correctanswer-Extended wand type discharge devices
Where a hazard is protected by an automatic fire protection system, a ___________ should be placednear the extinguisher stating that the FPS shall be _________ prior to using the extinguisher - Correct answer-PlacardActuated
___________ fire extinguishers shall not be installed for the protection of electronic equipment -Correct answer-Dry Chemical
Dry chemical fire extinguishers shall not be installed for the protection of __________ - Correct answer-Electronic Equipment
Only _______ type extinguishers shall be installed in areas containing oxidizers (Pool Chemicals) -Correct answer-Water
___________ __________ Fire extinguishers shall not be installed in areas containing oxidizers - Correctanswer-Multipurpose Dry Chemical
The installation of extinguishers should be __________ of whether the building is equipped with ______________, _______ and _______, or other _____ ________ _________ - Correct answer-Independent Automatic sprinklers Standpipe and hosefixed protection equipment
Extinguisher readiness - Correct answer-Extinguishers should be maintained in a fully charged andoperable condition and shall be kept in their designated places at all times when not being used
Fire extinguishers shall be located on ______ ______ __ _______ including ______ from areas - Correctanswer-normal paths of travel Exits
Fire extinguisher shall not be ______ from view - Correct answer-obstructed In large rooms and locations where visual obstructions cannot be completely avoided....... - Correctanswer-Means shall be provided to indicate the extinguisher location
Signs that indicate fire extinguisher locations should (^1) 2 - Correct answer-Be located in close proximity of the extinguisher Be visible from the normal path of travel Extinguishers with a gross weight not exceeding 40 lbs should be installed so that the top of theextinguisher is not....... - Correct answer-More than 5 ft above the floor
extinguishers with gross weight greater then 40 lbs should be installed so that the top of theextinguisher is....... - Correct answer-No more than 3 1/2 feet above the floor
The clearance between the bottom of the floor and extinguisher should never be less than..... - Correctanswer-4 inches
Extinguisher operating instructions should be located on the ________ of the extinguisher - Correctanswer-Front
HMIS labels, 6 year maintenance, hydrostatic test labels or other labels should not be located or placedon ........ - Correct answer-The front of the extinguisher
Cabinets housing fire extinguishers shall not be locked, except where fire extinguishers are subject to_________ ___ and include a means of emergency access - Correct answer-Malicious use
Extinguishers mounted in cabinets or on the walls shall be placed so that the ...... - Correct answer-Operating instructions face outward
Closed cabinets containing extinguishers that are exposed to elevated temperatures should be providedwith ______ ______ and _______ - Correct answer-Screened openings and drains
Extinguishers containing only plain water shall be protected to temperatures as low as _________ -Correct answer--40F
________ helps protect plain water extinguishers from freezing temperatures - Correct answer-Antifreeze
_______ ________ ________ should not be used in stainless steel extinguishers - Correct answer-Calcium Chloride Solutions
Minimum number of Extinguishers for Class A Hazards on each floor is determined by - Correct answer-Dividing total floor area by maximum area to be protected per extinguisher
Extinguishers should be located so that the maximum travel distances shall not exceed _________ -Correct answer-75ft
Smaller fire extinguishers that are rated on Class B and Class C fires but do not have a minimum 1-Arating shall ________ be used to meet the requirements for 6.2.1. - Correct answer-not
When the area of the floor of a building is less than table 6.2.1 specifies, at least ___ extinguisher of the_______ size shall be provided - Correct answer- Minimum Extinguishers shall not be installed for the sole protection for flammable liquid hazards of appreciabledepth where the surface area exceeds _________ - Correct answer-10ft^
If personnel who are trained in extinguishing fires in the protected hazards are located on the premisesand can respond quickly, the Maximum surface area must not exceed ________ - Correct answer-20ft^
for flammable liquid hazards of appreciable depth, a Class B extinguisher should be provided that has atleast _____ numerical units of Class B extinguishing potential per 1ft^2 of flammable liquid surface of the _______ hazard area - Correct answer- Largest Travel distances for portable fire extinguishers should not exceed - Correct answer-50 ft A hand portable fire extinguisher positioned for obstacle, gravity/3d, ir pressure fire hazards, should nothave an actual travel distance of more than _______ft - Correct answer-30ft
Wheeled fire extinguishers weighing 125lb or more are installed or positioned for obstacle, gravity/3d,the actual travel distance should not exceed _________ft - Correct answer-100ft