NFPA 70E Electrical Hazard Safety Questions and Answers 2024, Exams of Advanced Education

NFPA 70E Electrical Hazard Safety Questions and Answers 2024 The 3 hazards of electricity are? - CORRECT ANSWERS-Shock, Arc Flash, Ark Blast When an individual disconnect device in an energized MMC has been locket out, that MCC is... - CORRECT ANSWERS-Still a potential Arc Flash risk When working within the restricted approach boundary which is REQUIRED in order to perform non-electrical work near energized equipment? - CORRECT ANSWERS- The Crushed Gravel in an electrical substation is intended to... - CORRECT ANSWERS-Increase the resistance of worker to ground An example of elimination as a risk control method is... - CORRECT ANSWERS-Scheduling off-shift maintenance The purpose of the NFPA 70 E is... - CORRECT ANSWERS-Practical safe working requirements relative to the hazards from the use of electricity

Typology: Exams

2023/2024

Available from 08/29/2024

Academician
Academician 🇺🇸

4.3

(10)

3.3K documents

1 / 3

Toggle sidebar

Related documents


Partial preview of the text

Download NFPA 70E Electrical Hazard Safety Questions and Answers 2024 and more Exams Advanced Education in PDF only on Docsity! NFPA 70E Electrical Hazard Safety Questions and Answers 2024 The 3 hazards of electricity are? - CORRECT ANSWERS-Shock, Arc Flash, Ark Blast When an individual disconnect device in an energized MMC has been locket out, that MCC is... - CORRECT ANSWERS-Still a potential Arc Flash risk When working within the restricted approach boundary which is REQUIRED in order to perform non-electrical work near energized equipment? - CORRECT ANSWERS- The Crushed Gravel in an electrical substation is intended to... - CORRECT ANSWERS-Increase the resistance of worker to ground An example of elimination as a risk control method is... - CORRECT ANSWERS- Scheduling off-shift maintenance The purpose of the NFPA 70 E is... - CORRECT ANSWERS-Practical safe working requirements relative to the hazards from the use of electricity For the purpose of on the job learning and when escorted by a qualified person, an unqualified person may cross the... - CORRECT ANSWERS-limited approach boundary An example of administrative control is... - CORRECT ANSWERS-worker rotation One example of specific employee responsibility is... - CORRECT ANSWERS- Inspection of PPE before use You open a circuit breaker and expect a specific motor to shut down, but it continues to run, the best course of action is... - CORRECT ANSWERS-Stop and obtain further direction before proceeding The amount of heat energy required to raise the temperature of 1 gram of water by 1 degree Celsius is a... - CORRECT ANSWERS-Calorie Ruled-base, Knowledge-based, Skill-based are ______ ______ modes. - CORRECT ANSWERS-Human Performance The 3 basic cause of electrical incidents include unsafe conditions, unsafe equipment and ... - CORRECT ANSWERS-unsafe acts The highest voltage class for gloves is what color/number? - CORRECT ANSWERS- Class 4 Color Orange The ATPV of a material is how long it withstand thermal energy before there is a 50% probability that it will... - CORRECT ANSWERS-Create a hole in the material The color code for a class 1 glove is... - CORRECT ANSWERS-White A shock risk assessment should identify... - CORRECT ANSWERS-The presence of concealed, covered, or guarded energized parts that would be exposed when a boundary or barrier is bypassed. The purpose of an arc flash risk assessment is to... - CORRECT ANSWERS-Anticipate incident energy and set the arc flash boundary Temporary ground jumpers are connected first... - CORRECT ANSWERS-to ground then to line In an arc flash risk assessment, the presumed working distance for low voltage MCC's and panel is... - CORRECT ANSWERS-18" What is the minimum CAT rating to test a 120v receptacle? - CORRECT ANSWERS- CAT 2 Justification for work on live electrical include... - CORRECT ANSWERS-equipment design creates a greater hazard According to NFPA 70 E 110.6(c), emergency response training includes... - CORRECT ANSWERS-Selection of PPE and insulated tools The energized electrical work permit process is used to... - CORRECT ANSWERS-Plan and authorize the work Regarding safe work practices, Which is TRUE? - CORRECT ANSWERS-Perform only the planned work Regarding working energized (Live), a worker has a right to... - CORRECT ANSWERS- Refuse to do the job if they feel its unsafe or unqualified The minimum category of meter for a distribution panel is... - CORRECT ANSWERS- CAT 4 Energized conductors or circuit parts must be put into an electrically safe work condition before an employee... - CORRECT ANSWERS-Works within the limited approach boundary