Download NFPA 70E Exam With 100% Correct And Verified Answers 2024 and more Exams Advanced Education in PDF only on Docsity! NFPA 70E Exam With 100% Correct And Verified Answers 2024 What is mainly covered in chapter 2 of the NFPA 70E standard? C. Maintenace Which article in Chapter 1 of NFPA 70E contains common definitions? A. 100 The National Fire Association (NFPA) developed and maintains the NFPA 70E standard for electrical safety. What year represents the current edition of the NFPA 70E? D. 2018 The NFPA 70E covers electrical safety in the workplace as it pertains to______ B. Human Information on human factors and performance, such as human error, can be found within: D. Annex Q Within the 2018 NFPA 70E standard, what indicates a revision to text from previous versions? D. text shading What does the NFPA 70E standard now considered first priority when it comes to electrical hazards? A. Elimination of the hazard When a company has a "no live work" policy, there is still a danger that an employee will come in contact with live electricity. A. True When it comes to electrical safety, who is responsible for employee safety? D. Both A and B When developing an electrical safety program, its is best to refer to what area of the NFPA 70E standard? C. Both A and B Training for qualified persons is the same as for unqualified persons. B. False What is the main way to establish an electrically safe work condition? C. Implementing a lockout/tagout program A qualified person designation is both task and________specific B. Equipment A licensed electrician automatically meets the definition of a qualified person, according to NFPA 70 E B. False Employer are required to ensure qualified person compliance with safety-related work practices through: D. Both A and B Prior to energized electrical work: A. a qualified person must perform shock and arc flash risk assessments Arch flash hazards include: D. All of the above NFPA 70E states that equipment should be de-energized unless: D. Both A and B An unqualified person may cross which of the following boundaries: B. Limited approach boundary, when continually escorted by a qualified person. Owners of non-dwelling electrical equipment that is likely to require examination, adjustment, servicing, or maintenance while energized shall mark such equipment with a: Shock/arc flash warning label Under NFPA 70E, the appropriate PPE for arc flash can be determined by: C. Using the tables found in Article 130.7(C)(15) NFPA 70E states that all PPE must meet one of three levels of: B. Conformity Tools used for working on electrical equipment should be: A. Insulated and rated for the voltage you are working with Gloves must be inspected and tested prior to use, and be certified every: B. 6 months Energized electrical work permits have______critical elements C. Nine