NYC FSD CLASS FULL TEST EXAM 2024\2025 WITH GUARANTEED ACCURATE ANSWERS, Exams of Nursing

NYC FSD CLASS FULL TEST EXAM 2024\2025 WITH GUARANTEED ACCURATE ANSWERS Which of the following audible alarm sequences is not correct? A. Low-rise non-fireproof buildings may sound the alarm on all floors. B. Alarm sounds on the fire floor only. C. Sounds in zones or groups of floors. -B. Alarm sounds on the fire floor only. While acknowledging trouble conditions for a lower floor, an alarm

Typology: Exams

2024/2025

Available from 11/04/2024

tenetiii-salvy
tenetiii-salvy 🇺🇸

3

(1)

1.3K documents

1 / 41

Toggle sidebar

Related documents


Partial preview of the text

Download NYC FSD CLASS FULL TEST EXAM 2024\2025 WITH GUARANTEED ACCURATE ANSWERS and more Exams Nursing in PDF only on Docsity! NYC FSD CLASS FULL TEST EXAM 2024\2025 NYC FSD CLASS FULL TEST EXAM 2024\2025 WITH GUARANTEED ACCURATE ANSWERS Which of the following audible alarm sequences is not correct? A. Low-rise non-fireproof buildings may sound the alarm on all floors. B. Alarm sounds on the fire floor only. C. Sounds in zones or groups of floors. -B. Alarm sounds on the fire floor only. While acknowledging trouble conditions for a lower floor, an alarm condition registers at the fire command station for an upper floor. What action should you take? A. Alert upper floor fire wardens, activate brigade, and verify that the FD has been notified. B. Due to troubles on lower floor, ignore alarm for the moment. C. Send brigade to lower floor first then to upper floor condition. D. Call FD and report both trouble and fire alarm conditions for the building. --A. Alert upper floor fire wardens, activate brigade, and verify that the FD has been notified. All of the following items are to be tested or serviced annually EXCEPT: A. Pull Stations B. Water Flow Alarms C. Smoke Detectors D. Speaker/strobe --B. Water Flow Alarms Initiating devices cause the alarm panel actions EXCEPT: A. Area smoke detectors recall elevators. B. Manual pull stations do not unlock fail safe reentry doors. C. Sprinkler water flow alarms recall elevators. D. HVAC duct smoke detectors shut off associated fan units. --A. Area smoke detectors recall elevators. Which is not a responsibility of a High Rise office building owner? A. to train the fire brigade. B. to provide for fire drills C. designate a Fire Safety Director D. provide for a written Fire Safety Plan --A. to train the fire brigade C. security D. front desk clerks ---A. guests When may office building fire wardens order the use of elevators? A. as needed B. never C. elevator banks unaffected by the fire with permission of FSD D. before the smoke detectors recall elevators in the early stage of the fire ---C. elevator banks unaffected by the fire with permission of FSD A 30,000 sq/ft office floor would require how many deputy floor wardens? A. one B. two C. three D. four ---D. four (one every 7,500 sq/ft) Who selects persons for the fire warden team? A. tenant B. building owner C. Fire Safety Director D. Building Evacuation Supervisor ---A. tenant When would fire wardens NOT begin evacuation of their floor? A. upon orders to evacuate from the Fire Safety Director and no sign of fire B. when seeing smoke at ceiling level C. with alarm sounding but ordered to stand by from the Fire Safety Director D. when the office floor is below grade ---C. with alarm sounding but ordered to stand by from the Fire Safety Director Instructions for the fire brigade members does NOT include: A. reporting to the fire floor and attempt to extinguish small fires B. leaving one member on the floor below the fire to meet the fire department C. attempting to control fire if conditions pose not personal threat D. upon arrival of the Fire Department on floor below, brigade returning to lobby ----A. reporting to the fire floor and attempt to extinguish small fires What conditions permit the use of elevators during a high-rise fire emergency? A. when the elevator bank serves the fire floor B. only if the cars are operated by the fire brigade C. for brief periods when the fire is small D. when elevators do not serve the fire floor and have no shaft openings on floors affected by the fire or smoke ---D. when elevators do not serve the fire floor and have no shaft openings on floors affected by the fire or smoke Which is NOT an objective of a Fire Safety Plan? A. to establish method for response to alarms B. to educate employees to report fires promptly C. to train floor warden teams to fight fires D. to safeguard human life and contain fire ---C. to train floor warden teams to fight fires Which item is NOT described as a key element of a Fire Safety Plan? A. Signage B. Names of all floor wardens C. Floor plans D. building information form details ---B. Names of all floor wardens Supervisory signals monitor all of the following items EXCEPT: A. Battery operated smoke detectors in hotel rooms. B. Fire pump electric power. C. Pressure tank water levels. D. Gravity tank water temperature ---A. Battery operated smoke detectors in hotel rooms. Class E & J (class B & R-1 new code) systems have three distinctive features. Those are: A. Sprinklers, standpipes, pull station. B. Pull stations, warden phones, elevator recall. C. Selective interior alarm system, public address, 2 way voice communications. D. Interior alarms, strobes, public address system. C. avoiding attack stairs D. Using smoke-free stairs ---B. waiting for instructions During a fire, when may a multi-bank elevator be used? A. when they serve the fire floor B. when smoke-free C. when cars manned by trained building personnel or firefighters D. never during a fire ---C. when cars manned by trained building personnel or firefighters Where may floor organization charts be posted? A. in a conspicuous location in each tenancy and on each floor of a tenancy that occupies more than one floor B. at Fire Command Station C. at the Fire Safety Director's office D. by all elevators ---A. in a conspicuous location in each tenancy and on each floor of a tenancy that occupies more than one floor Fire Wardens are required to do all of the following EXCEPT: A. provide identification bands or hats during drills or alarms for fire B. assure all persons on the floor are notified C. after evacuation, provide a head count D. during alarms be first to leave the floor, to set an example D. during alarms be first to leave the floor, to set an example All are duties of the Fire Brigade EXCEPT: A. report to floor below fire to assist in evacuation B. assist building occupants that require assistance C. operate small hose line to control fires D. on arrival of Fire Department, report to the lobby ----C. operate small hose line to control fires What is not required of fire wardens for evacuating disabled persons from high-rise floors? A. keep updated list of persons needing assistance B. arrange quick use by elevators C. notify Fire Saftey Director when assistance is needed ---B. arrange quick use by elevators Fire Wardens who discover a fire on their floor must: A. determine that an alarm has been transmitted B. search and rescue all floor occupants C. report immediately to firefighter on floor below fire D. report in person to the Fire Command Station ---A. determine that an alarm has been transmitted All is true about the Deputy EAP Director EXCEPT: A. fills in for the EAP Director in his absence B. needs a Certificate of Fitness C. trains all EAP staff D. only required in an office building ---C. trains all EAP staff Fire Safety Brigade members can be: A. Building personnel B. office employees C. other building occupants D. all of the above ----D. all of the above Buildings are required the following permits: A. Commercial Cooking System B. Places of Assembly C. ... All are duties of a fire warden except: A. assure all persons are notified of fire and evacuated to safe areas B. Keep the Fire Command Station informed of the means being employed for evacuation by the occupants of his floor C. when alarm is received fire wardens leave floor immediately D. have updated list of disabled who cannot use stairs. ----C. when alarm is received, fire wardens leave floor immediately What group is mentions in the office plan and left out in the hotel plan? A. Fire Warden teams B. Fire Brigade C. Deputy Fire Safety Director D. Building Staff (employees) ----A. Fire Warden teams All of the following building occupants are given their parts of the related fire safety plan except: A. Floor Wardens B. Deputy Fire Safety Directors C. Fire Warden D. Firefighter ---D. Firefighter What is not a factor in the selection of an evacuation stair that a floor warden should otherwise consider? A. location of the fire B. smoke in a stairway C. stair leads to roof D. direction from the Fire Command Station ---C. stair leads to roof Hotel Fire Safety Directors shall do all EXCEPT: A. train and supervise Fire Brigade B. conduct fire drills C. order full building evacuation of guests D. distribute applicable parts of the Fire Safety Plan to all employees ----C. order full building evacuation of guests A Fire Safety and Evacuation Plan is required in all of the following except: A. Group B (Business) occupancy office buildings occupied or designated to occupied by more than 500 persons on one or more floors, including street level, or by more than 100 persons on one or more floors other than street level. B. Covered malls exceeding 40,000 sq. ft. in aggregate floor area C. Group R-1 (Residential, Transient) occupants, occupied by more than 30 lodgers, or more than 15 lodgers above street level, for a period of 90 days or less. D. Group R-1 (Residential, Transient) occupancies occupied by one or more lodgers on a floor more than 75 feet above street level, for such period of 90 days or less. ---B. Covered malls exceeding 40,000 sq/ft in aggregate floor area. (it is 50.000 sq/ft) Fire pumps are monitored at the central station for what status? A. Failure of electric power supply and automatic operation of electric fire pumps. B. Pump pressures C. Gallons flow D. Temperature of the water -----A. Failure of electric power supply and automatic operation of electric fire pumps. Required alarm log book does not include: A. Which FSD is on duty by date and time B. Daily lamp test status C. Manual false alarm details D Off/On line details ----C. Manual false alarm details Fire drills in new office building must be conducted how many times a year? A. one B. two C. three D. four ---D. Four (quarterly) A walk up tenemant less than 75 feet in height rents out 5 rooms on each of 4 floors by the month with no stay limits. It is not a hotel. Why? A. Hotels rent for less than 90 days. B. There are 25 rooms for rent. C. Building is less than 75 feet in height. D. Furnished room houses have no guest limits. ----A. Hotels rent for less than 90 days. A daily visual inspection of the fire command station should insure what status? A. No alarms have gone unanswered. B. Fireman's service is operable. C. The central station (office) connection works. D. System is on-line and trouble conditions are logged. B. Two C. One and cellar D. All floors ----A. One Fire safety evacuation plan required for Occupancies & Buildings:- Group A(Assembly)Used exclusively for purposes of religious worship that have an occupant load LESS than 2,000. Fire safety evacuation plan required for Occupancies & Buildings: Group B (Business) 1. occupancy office buildings occupied or designed to be occupied by 500 persons on one or more floors, including street level. 2. by more than 100 persons on one or more floors other than street level. Fire safety evacuation plan required for Occupancies & Buildings: Group R-1:-(Residential / Hotels) 1. occupied by more than 30 lodgers, or more than 15 lodgers above street level, for a period of 90 days or less 2. operated to accommodate such numbers of lodgers for such period of occupancy. 3. designed to contain a total of more than 30 sleeping rooms, or more than 15 sleeping rooms above the street level for such period of occupancy. 4. occupied by one or more lodgers on a floor more than 75 feet above the street level. Fire safety evacuation plan required for Occupancies & Buildings: General Info:- -Covered malls exceeding 50,000 sq/ft in aggregate floor area. -Buildings that are greater than 6 stories or 75 feet (22 860 mm) in height, except Group R-2 occupancies. -Buildings occupied or designed to be occupied to provide emergency shelter for more than 15 homeless persons for more than 30 days in a year. Access Stairs--A stairway, usually open, serving a number of floors of a common tenant. AKA Convenience Stairs Attack Stairway-A fire stair being used by the Fire Department to gain access to the fire area, where the door between the stairway and the fire area is being maintained in an open position. ->standpipe riser Blind Shaft Elevators-Elevators serving upper areas of a building in a shaft that is not equipped with hoistway doors on the lower floors. Building Evacuation Supervisor-(employee) When the Fire Safety Director is not present in a class "B" office building occupied by less than 100 people above or below street floor/level or by less than 500 people in the entire building, an employee trained by the fire safety director will man the fire command station and execute the fire safety plan. Churning--A condition in a centrifugal pump in which the impeller is rotating but no water is being discharged. Compartmentation--The subdividing of floor areas by fire resistant separations into smaller spaces or compartments. Elevator Control Panel--A visual unit located in the lobby to indicate the status and location of all elevator cars and necessary controls the operation of the cars. Elevator Machinery Room--The area where the equipment is located that raises and lowers the elevator car. In high-rise buildings usually at top of shaft. Evacuation Stairway-"Fire Tower" or a fire stairs that is remote from the fire area and used for the evacuation of the building occupants. Fire Safety Director-A designated employee holding a certificate of fitness from the Fire Department qualifying him to perform the duties as required. Fire Tower-An enclosed stairway connected at each story by an outside balcony or fireproof vestibule vented to the outside. (preferred evacuation stairway) Fusible Link-A device designed to be actuated by an abnormal rise in temperature. An unobstructed path (vertical / horizontal) of travel for occupants to exit a building-Means of Egress The portion of a means of egress system which is separated from other interior spaces of a building or structure by fire-resistance-rated construction and opening protectives as required to provide a protected path of egress travel between the exit access and the exit discharge.--Exit Exit Access-The portion of means of egress system that leads from any occupied portion of a building, structure or premises to an exit. Exit Discharge-The portion of a means of egress system between the termination of an exit and a public way. Alarm supervisory signal-monitors the sprinkler / standpipe system for problems w/ equipment and when standpipe hoses have been activated. Water Flow Alarms-Give warning of the actual occurrence of a fire or other conditions such as broken piping Pressure Tank Alarms-provides primary water supply of a sprinkler; automatically controls the air-to-water ratio which is always 1 to 2. OS & Y (Outside Screw & Yoke)-Gate valves that are installed at several places in the system. Used to shutdown just a part of standpipe system. -If stem is raised OUT above control wheel, valve is open. -If stem is flush IN with the control wheel, valve is closed. Nozzle - Discharge Device-designed to discharged water in a fixed or adjustable pattern. Examples are SPRAY nozzles and HOSE nozzles. -Every point in the floor area served by the hose station is within 20 feet of the end of hose nozzle. Maximum length of hose line is 25 feet. What operation can the #1620 Key perform? A. Recall all elevator banks B. Open pull stations C. Turn on purge fans for selected floors D. Purge all floors at once --C. Turn on purge fans for selected floors What position does the Fireman's Service key switch in the car have? A. Normal -Fireman's Service - Hold B. Normal - Rum C. Fireman's Service -Hold D. Fireman's Service - Hold – Run --A. Normal -Fireman's Service - Hold The Fire Command Station panels have three distinctive elements. Which item is not a distinctive element of the Fire Command Station panel? A. Alarm panel B. Warden Phone System C. ABC Fire Extinguisher D. Public Address Speakers --C. ABC Fire Extinguisher When is the central station connection tested?-Monthly Where are phone jacks in class J-1 (class R-1 new code) occupancies installed?-In stairwell near the standpipe riser(s) Fire Command Station have 3 distinctive elements:-1. Alarm Panel 2. Warden Phone Systems 3. Public Address Speakers Public Address Speakers-Loud speakers on each floor of the building, in each elevator and each stair enclosure, capable of being operated from the fire command station. Allows communication throughout the entire building. Fire alarm sending stations-for all systems shall be painted red. A diagonal white stripe or applied to sending stations which transmit a fire alarm signal to the fire department via a central station Smoke detectors-in elevator lobbies and machinery rooms recall all elevators in the effected bank of cars to the main lobby or alternate Actuates the automatic extinguishing systems in the protected area.-Area Detectors If an existing office building is fully sprinklered, what is the maximum size of the office area? A. Unlimited area B. 10, 000 sq/ft C. 15,000 sq/ft D. 7,500 sq/ft --A. Unlimited area What is the purpose of stair pressurization for hi-rise buildings?-Positive pressure of uncontaminated air to keep fire and smoke inside the fire floor spaces. What is the purpose of compartmentation? A. Keep fire small on lowest floors B. Reduce smoke levels in the stairs C. Control showroom fires D. Limit size of the fire areas on upper floors --D. Limit size of the fire areas on upper floors When must showrooms in the buildings classified in occupancy group E, 100 ft or more in height having air-conditioning and/or mechanical ventilation systems that serve more than the floor in which the equipment is located be sprinkler protected?-More than 40 feet above street and over 7,500 sq/ft area Where and when is a duct smoke detector required? A. At the supply and return side, regardless of the size of the unit. B. At the return side of the fan if over 2,000 CFM C. Mechanical equipment room D. At the supply side only of units over 15,000 CFM --B. At the return side of the fan if over 2,000 CFM Which alarm device does not turn on pressurization fans?-Manual pull stations only Lightweight post-1968 code construction is non-combustible, primarily due to which feature?-Floor assemblies not smoke tight Re-entry rules include all except: A. Office buildings under 100 feet require re-entry every four floors B. Office buildings may elect to lock stair side doors except every four floors re-entry must be provided C. Re-entry starts at the uppermost occupied floor. D. Fail-safe locks released on re-entry floor w/ automatic actuation device operation. --A. Office buildings under 100 feet require re-entry every four floors Office buildings under 100 feet have no re-entry, what sign is posted on the occupancy side?-"No Re-entry From This Stair" sign and stair ID Letter Elevator landing sign reads:-"IN CASE OF FIRE, USE STAIRS UNLESS OTHERWISE INSTRUCTED", Elevator bank ID Letter, and Floor diagrams Hotel sleeping room sign details what information?-Diagram showing stair locations What signs are posted on hotel exit doors - on floor side?-Letter ID What is NOT a common feature of a class E or J (class B & R-1 new code) system? A. coded interior alarms B. Alarm points, public communication and 2-way warden phone. C. Two way communication D Selective audio/visual alarms to floors --A. coded interior alarms All of the following items add to hi-rise office building fire safety (impact) except: A. Insures orderly evacuation information via public address system B. restricts office sizes C. Requires sprinklers D. Gives a fire action plan to tenatns and building staff --C. Requires sprinklers What occupancies did Local Law 42/78 require retroactive sprinkler protection?-Dressing Rooms and property rooms used in places of Assembly except Assembly Place w/ no scenery. What is the flash point of any flammable liquid?-The temperature at which the vapors' ignition will occur. Which condition(s) of a material will produce burning of the material? A. Flammable glass in air B. Flammable liquid at the fire point temperature. C. Ignition temperature of a solid. D. All of the above ---D. All of the above Which is the better extinguisher to use for a mattress fire A. Pressurized Water B. Foam C. Dry chemical powder D. Carbon dioxide gas --C. Dry chemical powder Un-sprinklered offices and hotel floors require one extinguisher for what square footage and placed within what travel distance?-6,000 sq/ft for every 75 feet What state must all burnable substances be reduced to burn in air?-Gas At what temperature must any substances be raised to burn freely in air?--Fire point temperature A 10,000 sq/ft place for public assembly includes a 20x90 commercial kitchen. How many and what type extinguishers are required at the minimum?--Four water and two "K" type A 7,500 sq/ft retail store located in the lower lobby of a hotel would require how many of what type extinguishers?-Three 2-A rated extinguishers How often should commercial cooking systems grease filters be cleaned?-Monthly What distance should the manual release station be from the range hood?-10 feet minimum and 35 feet maximum (new installation 20 feet max) How often and by whom is the commercial cooking system inspected?- Semi-annually by a licensed contractor What is a dry pipe controlled by pressurized air called?-Automatic Dry Pipe What part of the tetrahedron does Inergen remove to put out fires?- Oxygen What gas is not present in the Inergen agent?-Halon What "trips" a dry pipe sprinkler system?--When a fused sprinkler head lowers air pressure on a clapper Which of the following is required to be flameproofed by NYC code? A. Office drapes B. Clothing for sale C, Clothing for display museums D. Scenery for a Broadway play ---D. Scenery for a Broadway play Which is a flameproof process for fiberglass draperies?-Admixture Which space is exempt from flameproofing rules in NYc?-Large churches What is maximum time between flameproof applications?-3 years What event(s) reduce the time between flame proofing applications? A. failing the small scale test B. Only if washed during the period C. If dry-cleaned during the warranted period D. Any one of the choices ---D. Any one of the choices All affidavits of flameproofing must be sent to which gov't agency?- Bureau of Fire Prevention Trouble Signals---A signal initiated by the fire alarm system or device indicative of a fault in monitored circuit or component that needs to be investigated and corrected. How many fire extinguishers are required in Public Assembly (gathering of at least 75 ppl) areas ---One 2-A fire extinguisher for every 2,500 sq/ft Flash Point--The lowest temperature of the liquid at which it gives off vapor sufficient to cause a flammable mixture with air near surface of liquid. Fire Point--The lowest temperature at which a substance continues to burn in air. Locked door Fail-Safe System: Re-entry doors will unlock if... 1. Any automatic fire directing device operates 2. Elevator Firemen Service operates 3. Power Failure NB.These doors can be opened from the command station or mechanical control center Re-entry Stairwells 1. Top building, minimum of every 4th floor 2. Buildings under 100 ft tall, all doors may be locked from the stair side above the street floor. 3. Buildings over 100 ft, doors may be locked on the stair side EXCEPT intervals of 4 stories Prior to taking the system out of service, the Impairment Coordinator must notify: 1. Central station company 2. Fire Department Borough Dispatcher 3. Insurance carrier 4. Occupants in the effected area(s) 5. and make appropriate recommendations to management or owner