Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Oil Furnace Heating Practice Tests Questions With Answers 100% Solved., Exams of Oil Engineering

1. Question 1 points Fuel Pump fail to prime when Suction inlet vacuum is greater than _______ of vacuum 20 inches 30 inches 15 inches 25 inches - ✔✔✔ - 15 inches Which of the following is used to ignite the fuel oil in the heating system? Step down transformer Step up transformer - ✔✔✔ - Step up transformer Air enters the heating system in following order: From combustion chamber, to turbulator, to draft tube From draft tube, to turbulator, to combustion chamber

Typology: Exams

2024/2025

Available from 11/22/2024

Academician
Academician 🇺🇸

4.5

(14)

3.9K documents

1 / 4

Toggle sidebar

Related documents


Partial preview of the text

Download Oil Furnace Heating Practice Tests Questions With Answers 100% Solved. and more Exams Oil Engineering in PDF only on Docsity!

Oil Furnace Heating Practice Tests Questions

With Answers 100% Solved.

  1. Question 1 points Fuel Pump fail to prime when Suction inlet vacuum is greater than _______ of vacuum 20 inches 30 inches 15 inches 25 inches - ✔✔✔ - 15 inches Which of the following is used to ignite the fuel oil in the heating system? Step down transformer Step up transformer - ✔✔✔ - Step up transformer Air enters the heating system in following order: From combustion chamber, to turbulator, to draft tube From draft tube, to turbulator, to combustion chamber From turbulator, to turbulator, to combustion chamber - ✔✔✔ - from draft tube, to turbulator, to combustion chamber

Malfunctions in the heating system cause primary safety control to _______ electrical resistance across the cell until the burner is automatically shut off. Reduce Increase - ✔✔✔ - increase A ______ carbon dioxide content is usually caused by insufficient draft or an overfired burner Low High - ✔✔✔ - high A _______ stack thermometer is generally used to measure the flue gas temperature in oil heating system: 200/2000°F 100/1000°F 200/1000°F 100/2000°F - ✔✔✔ - 200/1000°F Delayed ignition is mainly traced to a problem with which of the following: Stoker Electrodes Burner Nozzle Oil pump - ✔✔✔ - Electrodes

The advantage of the _______ of oil spray pattern is more stable operating under the same conditions and at the same flow rate. Hollow cone Solid cone - ✔✔✔ - hollow cone Rotary burners operate with high-pressure gravity False True - ✔✔✔ - False Which of the following oil burner has relatively high operating cost Vaporizing oil burner Pot-type oil burner Gun type oil burner - ✔✔✔ - Gun type oil burner If the oil tank is located above the burner, and the oil is supplied by gravity flow, the vacuum gauge must show a reading of _______: Zero Positive value Negative value - ✔✔✔ - zero

In two stage oil pump the _______ stage draws completely air-free oil: Both first and second Second First - ✔✔✔ - second The spray angle of oil from burner nozzle will generally range from ______: 60° to 90°. 30° to 90° 45° to 90° 70° to 90° - ✔✔✔ - 30° to 90° Fuel pump is located on the left side of the oil burner True False - ✔✔✔ - True ______ gives a twisting motion to the air stream just before it strikes the oil spray Stoker Turbulator Rotary system Draft tube - ✔✔✔ - Turbulator