Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

OSHA 40 HAZWOPER TERMS FOR EXAM With Verified Correct Answers 2024, Exams of Advanced Education

OSHA 40 HAZWOPER TERMS FOR EXAM With Verified Correct Answers 2024 year the osh act was written - Correct Answer-1970 under the Dept of Labor Detailed Site-Specific Hazards Assessment must be performed according to what federal regulation? - Correct Answer-29 CFR 1910.120 29.CFR.1910.1200 Requires employees to - Correct Answer-1.Adopt a written hazard communication program 2.Keep SDS for chemicals on the site 3.Provide education and training to employees T or F: Chemical Safety Data Sheets (SDS) must be prepared by every chemical manufacturer - Correct Answer-True! New system that replaced the original HAZCOM Material Safety Data Sheet (MSDS) System - Correct Answer-GHS Global Harmonization System, simply called Chemical Safety Data Sheets (SDS). OSHA and EPA not interchangeable in their roles (what are their roles?) - Correct Answer-Protect human health and safeguard the environment (air, water and land).

Typology: Exams

2023/2024

Available from 06/18/2024

professoraxel
professoraxel 🇺🇸

3.7

(26)

9.1K documents

1 / 6

Toggle sidebar

Related documents


Partial preview of the text

Download OSHA 40 HAZWOPER TERMS FOR EXAM With Verified Correct Answers 2024 and more Exams Advanced Education in PDF only on Docsity! OSHA 40 HAZWOPER TERMS FOR EXAM With Verified Correct Answers 2024 year the osh act was written - Correct Answer-1970 under the Dept of Labor Detailed Site-Specific Hazards Assessment must be performed according to what federal regulation? - Correct Answer-29 CFR 1910.120 29.CFR.1910.1200 Requires employees to - Correct Answer-1.Adopt a written hazard communication program 2.Keep SDS for chemicals on the site 3.Provide education and training to employees T or F: Chemical Safety Data Sheets (SDS) must be prepared by every chemical manufacturer - Correct Answer-True! New system that replaced the original HAZCOM Material Safety Data Sheet (MSDS) System - Correct Answer-GHS Global Harmonization System, simply called Chemical Safety Data Sheets (SDS). OSHA and EPA not interchangeable in their roles (what are their roles?) - Correct Answer-Protect human health and safeguard the environment (air, water and land). General Site Workers must have a minimum of ??? - Correct Answer-40 hours of off- site instruction. General Site Workers and Treatment, Storage, and Disposal (TSD) workers must receive ??? hours of refresher training annually. - Correct Answer-8 Hours What Part under 29 CFR regulates EMERGENCY RESPONSE to hazardous substance releases - Correct Answer-29 CFR 1910.120 ==>(Q)<== What is the name of the standard that regulates Hepatitis B, HIV, AIDS - Correct Answer-Occupational Exposure to Bloodborne Pathogens 1910.1030 What is a hazardous substance? - Correct Answer-ANY substance designated as hazardous under ANY federal regulation. All matter can exist in three different physical states: Solid Liquid Gas DEPENDING ON - Correct Answer-Depends on temperature and pressure What is Specific Gravity (SG) - Correct Answer-ratio of mass of substance to mass of volume of water SG < 1.0 will float in water SG > 1.0 will sink in water T or F: Aerosols are not vapors or gases, but solid or liquid particles suspended in air. - Correct Answer-True Vapor Pressure is - Correct Answer-A measure of the rate of evaporation or volatization (or gives off vapor) from a liquid Vapor density is - Correct Answer-Vapor density equals the weight of a vapor or gas compared to the weight of an equal volume of air at the same temperature and pressure. Vapor Density >1 = Heavier than air Vapor Density <1 = Lighter than air Flash Point is - Correct Answer-the minimum temperature at which a liquid fuel produces enough vapor to burn momentarily Fire Point is - Correct Answer-The temperature at which enough vapors are given off to support continuous burning. Ignition (or Auto-Ignition) Temperature is - Correct Answer-The minimum temperature required to initiate or cause self-sustained combustion (burning) IN THE ABSENCE OF ANY SOURCE OF IGNITION Lower Explosive Limit (LEL) - Correct Answer-The percentage of the minimum concentration of vapors in the air necessary to have a fire or explosion. At 100% LEL, there are sufficient vapors in the air for a fire or explosion Upper Explosive Limit (UEL) - Correct Answer-The maximum concentration of vapor in the air, above which a fire or explosion will not occur in the presence of an ignition source. Between the LEL to the UEL is the - Correct Answer-Flammable Range T or F If the time spent in a particular radiation field is doubled, the worker's dose is doubled. and vice versa - Correct Answer-True True or False: If a PROPER shield (such as a particular filter respirator) is placed between the radiation source and a person, the dose will be eliminated or decreased. - Correct Answer-True OSHA requires Medical Records be kept for - Correct Answer-30 Years At what dB level is a hearing conservation program necessary? - Correct Answer-85 dB At what dB is are engineering or administrative controls required? - Correct Answer-90 dB Incident Commander - Correct Answer-The person responsible for all aspects of an emergency response Permeation - Correct Answer-Dissolves or moves through materials at molecular level. Degradation - Correct Answer-Loss or change in chemical resistance due to exposure or ambient conditions Penetration - Correct Answer-Movement through zippers, seams, or imperfections in suit Factors affecting the rate of permeation of a suit. - Correct Answer-Concentration of the hazardous substance. Suit material type and thickness. Temperature. Level A suits (9.7.2.1) - Correct Answer-Highest level of respiratory, skin, eye and mucous membrane protection is required Level B Suits (9.7.2.2) - Correct Answer-Highest level of respiratory, but lesser level of skin and eye protection. (minimum level of protective suits in IDLH conditions or when haz material is unknown). When is using a level C suit appropriate? - Correct Answer-When type of airborne substance is known, its concentration has been measured and criteria for using APRs have been met. Essentially, what is a Level D suit (9.7.2.4) practically speaking? - Correct Answer-A work uniform. When should a decon plan be put in place in the site response process? - Correct Answer-Before any personnel or equipment enter potential hazardous areas What can improper decon procedures can lead to - Correct Answer-Chemical reactions due to incompatibility. Release of toxic or flammable vapors. Degradation of PPE. Some decon scenarios require personnel to wear PPE at the same level as those entering Exclusion Zone (EZ) exceptions to this rule allow for??? - Correct Answer- decon personnel to wear level just below those entering EZ. Physical evidence may indicate that a HAZMAT incident is escalating - Correct Answer- −Frost forming near a leak (auto refrigeration) −Deformed containers (bulging drum) -"Pinging" vessel sounds Procedures to remember when opening haz waste/pressurized containers - Correct Answer-Do not lean over bung when opening drum Continuously monitor during opening procedure Decon equipment after each use to avoid mixing T or F: Under DOT the transporter is responsible for any kind of discharge during shipment - Correct Answer-True and if the spill exceeds reportable quantities the NRC must be notified immediately. Under DOT discarges of extremely hazardous substances require - Correct Answer- Immediate notification of local and state emergency planning committees. DOT requires a written report of the incident ERG (Emergency Response Guidebook) - Correct Answer-What do you refer to when responding to an incident involving Hazmat or hazardous materials? What are DOT Railroad shipping papers called? - Correct Answer-A Consist What are DOT papers found inside a trailer? - Correct Answer-A Manifest or a Bill of Ladden