S-12 CITYWIDE SPRINKLER SYSTEMS, S12 SPRINKLER TEST 2024-2025. QUESTIONS AND CORRECT VERIFIED ANSWERS. GRADED A
Typology: Exams
1 / 26
This page cannot be seen from the preview
Don't miss anything!
[Date]
[Date]
[Date]
Automatic Fill Pumps Supply The Water To Most Gravity Tanks. The Pumps Fill The Tank At A Rate Of __ Gpm - ANS AUTOMATIC FIRE PUMPS ARE USUALLY NEEDED WHERE A ___________ MAY OCCUR IMMEDIATELY. - ANSHIGH WATER DEMAND Blue Disk - Anspartially Out Of Service- On All Fire Department Connections Booster Pumps/Special Service Pumps - Ansbooster Pumps Are Sometimes Used In Sprinkler Systems. They Small Pumps With Limited Power Are Usually Located In The Basement Or Taking Suction From Gravity Tanks. The Booster Pump Is Used When The Water Pressure Available At The Highest Sprinkler Head Does Not Quite Meet The Needs Of The Sprinkler System. This Small Pump Increases The Water Pressure In The Sprinkler System Until It Reaches Acceptable Levels. The Booster Pump Should Not Be Confused With The Fire Pump Or The Jockey Pump. BOTH ACCLERATOR AND EXHAUSTER ARE ACTIVATED WHEN A DROP OF _______ PSI IS DETECTED IN THE SYSTEM. - ANS
[Date]
Centrifugal Pump Can Pump At A Rate Of - ANS25 To 5000 Gallons Per Minute CENTRIFUGAL PUMPS ARE CAPABLE OF DISCHARGING WATER FROM ____________ TO _________ GPM. - ANS25, 5000 COF HOLDERS SHOULD MANUALLY ACTIVATE THE FIRE PUMPS IAW ___________.
[Date] Deluge Valve - Answater Supply Control Valve Intended To Be Operated By Actuation Of An Automatic Detection System That Is Installed In The Same Area As The Discharge Devices. INTENDED USE IS MANUAL AND AUTO DRY PIPE VALVES ARE OF A ______ DESIGN. - ANSCLAPPER DRY PIPE VALVES ARE USUALLY SET AT ________ PSI ABOVE THE NORMAL TRIP LEVEL. - ANS15- Early Suppresion Fast Response Sprinklers - Ansfast Response Sprinkler That Is Listed For Its Capability To Provide Fire Suppression Of Specific High Challenge Fire Hazards Extended Coverage Sprinkler - ANS400 Max Square Feet Discharge 20 Foot By 20 Foot Spacing Between Sprinklers EXTERIOR EXPOSURE SPRINKLERS USE OPEN SPRINKLER HEADS TO FORM A _______ ON THE WALL OF A BUILDING. - ANSWATER CURTAIN Extra Large Orifice Sprinklers - ANS= Or > 1 Inch Less Pressure To Achieve A Given Discharge Density FACILITIES WITH 301-1000 SPRINKLERS REQUIRE ________ SPARES TO BE AVAILABLE. - ANS FACILITIES WITH LESS THAN 300 SPRINKLERS REQUIRE __________ SPARES TO BE AVAILABLE. - ANS
[Date]
Fire Command Center - Ansdesignated Room Or Area In A Structure Where The Status Of The Fire Detection, Alarm, And Protection Systems Is Displayed And The Systems Can Be Manually Controlled.
[Date]
Full Flow Test - Ansperformed Every 5 Years:
[Date]
Gravity Tanks Should Be How High Above The Highest Sprinkler Head? - ANS Feet. Green Tag - Ansno Impairment Found In Entire System- Main Control Valve GREEN TAGS INDICATE THAT __________. - ANSNO IMPAIRMENT WAS FOUND GREEN TAGS WILL BE PLACED ON THE ____________. - ANSMAIN CONTROL VALVE Hose Valve - Ansvalve To Additional Hose Connection Hydraulic Placard - Anssign Attached To A Hydraulically Calculated Sprinkler System Indicating The Design Density, Required Gallons Per Minute And Pressure For The System To Operate Properly Hydraulically Calculated Systems - Ansmethod Of Sizing Auto Sprinkler Piping Using A Prescribed Amount Of Water To Be Distributed Over A Specific Area. IF A FIRE HAS BEEN COMPLETELY EXTINGUISHED, THE __________ OR THEIR REPRESENTATIVE MAY CLOSE THE CONTROL VALVE. - ANSBUILDING OWNER
[Date] Large Orifice Sprinkler - Anssprinkler Head With Orifice Size Equal Or Greater Than 3/4 And Less Than 1 Inch Listed Device - ANSA Fire Protection Component That Has Been Tested To Perform Under Parameters Specified For Its Use By A Nationally Recognized Testing Agency. Underwriter's Laboratory (UL) And Factory Mutual (FM) Are The Two Most Common. Main Drain - Ansthe Primary Drain Connection Located On The System Riser And Also Utilized As A Flow Test Connection. Master Pressure Reducing Valve - ANSA Pressure Reducing Valve Installed To Regulate Pressures In An Entire Fire Protection System And/Or Standpipe System Zone. Microbiologically Influenced Corrosion (MIC) - Anscorrosion Caused By The Presence Of Microbes In The Water Supply That Over Time Attack The Interior Of Metallic Piping And Cause Leaks, Pitting, And Blockages. MINIMUM SIZE HANGER RODS FOR PIPE DIAMETER OF 10-12 INCHES: ___________. - ANS5/ MINIMUM SIZE HANGER RODS FOR PIPE DIAMETER OF 5-8 INCHES: ____________. - ANS1/ MINIMUM SIZE HANGER RODS FOR PIPE DIAMETER UP TO 4 INCHES: ___________. - ANS3/
[Date]
NON-AUTOMATIC DRY SPRINKLER SYSTEMS - Ansll Pipes Are Normally Dry. Water Is Supplied When Needed By Pumping Water Into The System Through The Fire Department Connection. Some Of These Systems Are Supplied By Manual Operation Of A Water Control Valve And May Be Equipped With Sprinklers With Or Without Fusible Links. There Are Several Non-Automatic Systems: 1) Perforated Pipe Systems - A Single Line Of Piping Drilled At Intervals For Water Discharge. These Systems Are Usually Found In Basements Or Other Areas Difficult To Reach In Fire Fighting Operations.
[Date] Of The Sprinkler Heads Open. A Supervisory Device Signals When The Valve Is Opened. The Preaction Valve Can Also Be Operated Manually. PREACTION SYSTEM ALARMS ARE GIVEN AS SOON AS THE _________ IS OPENED.
[Date]
Pressure-Reducing Valve - ANSA Valve Designed For The Purpose Of Reducing The Downstream Water Pressure Under Both Flowing (Residual) And Nonflowing (Static) Conditions. PRIMARY WATER PRESSURE TANKS SHALL BE EQUIPPED WITH TWO _____________. - ANSHIGH AND LOW ALARM SYSTEMS PRIOR TO RETURNING A SYS. TO SERVICE, THE ___________ SHALL ENSURE THAT NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - ANSIMPAIRMENT COORDINATOR Pump Activation - ANSA Fire Pump Can Be Started Automatically Or Manually. The Pump Can Be Started Automatically By An Electric Controller Or An Engine Controller. These Controllers Activate The Pump When There Is A Drop Of Water Pressure Or Water Flow In The Fire Protection System. PUMPS SHOULD BE ACTIVATED EACH WEEK AND RUN FOR _______ MINUTES IN ACCORDANCE TO THE MANUFACTURERS SPECIFICATIONS. - ANS
[Date]
Small Orifice Sprinklers - ANSA Sprinkler Head With And Orifice Size Smaller Than 1⁄2" Solder Link Sprinkler - ANSA Sprinkler Operated By The Melting Of A Metal Link, They Vary In Size And Configuration For Quick Response And Standard Response Sprinklers. The Smaller The Size Of The Link, The Faster The Sprinkler Operates. SOME METHODS TO PREVENT ICE INSIDE A GRAVITY TANK ARE _________. - ANSCIRCULATED HOT WATER, STEAM, STEAM COILS, AND SUN HEAT SPARE SPRINKLERS SHALL BE KEPT AT THE FACILITY WHEN THE TEMPERATURE DOES NOT EXCEED _________. - ANS100 DEGREES FAHRENHEIT Spray Sprinkler - ANSA Type Of Sprinkler Listed For Its Capability To Provide Fire Control For A Wide Range Of Fire Hazards. The Most Commonly Used Sprinkler Since 1953. SPRINKLER HEADS EXPOSED TO ___________ CONDITIONS ARE OFTEN COVERED WITH A COAT OF WAX, OR LEAD. - ANSCORROSIVE Sprinkler System Piping - Ansbranch Lines Are Directly Connected To Sprinkler Heads. Cross Mains Or Loop Mains Are Directly Connected To Branch Lines. Feed Mains Are Directly Connected To Cross Mains Or Loop Mains. Risers Are Able To Supply Feed Mains Or Cross Mains Directly.
[Date]
Standard Response Sprinkler Head - ANSA Sprinkler Having A Fusible Link With A Response Time Index (RTI) Of 80 Or More. STANDARD STEEL PIPE WITH DIAMETERS OF 1-1/4 INCH REQUIRE HANGERS TO BE PLACED __________ FEET APART. - ANS Supervisory Signal - ANSA Signal Indicating The Need For Action Or The Use Of Such Device In Connection With The Supervision Of Fire Alarm Systems Or The Maintenance Features Of Related Systems. Supervisory Signal-Initiating Device - Ansan Initiating Device, Such As A Valve Supervisory Switch,That Triggers A Supervisory Signal. System Control Valve - Ansvalve Controlling Flow To Water-Based Fire Protection Systems. SYSTEMS ABOVE _________ PSI HAVE DIFFERENT SUPPORT REQUIREMENTS. - ANS