Download S-12 S-13 Standpipe and Sprinkler Practice Questions and answers already graded A+| Update and more Exams Architecture in PDF only on Docsity!
"Fail Safe" when referred to in locks, means - ¥ Vthat the door can be opened if the power fails Where does the on-duty Building Evacuation Supervisor report when an alarm is activated? - / To the Fire Command Station ( To act as Fire Safety Director when the FSD or a Deputy FSD is not required to be on duty). "RCNY" is the abbreviation for - //Rules of the City of New York A fire alarm box is painted plain red (no stripe). When it is activated, an alarm will be sent- / /within the building Which of the following is a member of the Fire Brigade? - V V-Deputy Fire Safety, Fire Safety Director, Fire Warden None of the above. The function of the lower check valve is to - VV prevent back flow into the water main. The minimum distance of travel between fire extinguisher in a non-sprinkled class E building is - V/V 75 feet How must elevator banks and stairways be designed? - VV By letters in any order. Which of the following is required to be performed every 90 days? - VV Inspection/Cleaning of Range Hood Ducts and Filters A multipurpose fire extinguisher can be used on - / VClass A, B, and C fires. How long must the alarm log book be kept? - / V3 years One morning you are notified the roof gravity tank heater has burned out. Which of the following are you required to notify? - // Building Owner The function of the upper check valve is to prevent - VV Back flow into the gravity tank The primary duty of a fire brigade is to - VV evacuate occupants of building How often must communication to Central Station from the FSC be checked ? - /V Monthly If the stem extends from an OS&Y valve, it is an indication that the valve is - /Vopen What is a "blind" shaft way? - / WA floor where elevator cannot stop because there are no hoist way doors. Which of the following should NOT operate in a normal manner during phase 2? - / /Door Open Button A hotel is 60 ft tall and 40 sleeping rooms of which 10 are occupied. How many fire safety directors are required? -//1 When torch operations are done, the fire watcher must check for fire - VV during the operations, when the operations are complete, a half hour later and a half hour after that Diagrams require to be mounted in the hallways which show elevators, fire exits, etc. are called - ¥ Vfloor diagrams When a sprinkler head is said to "have fused" it means that it - / was exposed to the temperature at which it was designed to activate. Waterflow gongs are normally activated by the - / /Lower Check Valve In an automatic sprinkler system where one sprinkler has exceeded its temperature rating, how many sprinklers begin to spray water? - V /Only the sprinkler which has exceeded its rating Typically, a ball float would be found - / on the roof Which of the following is NOT a major defect of a sprinkler system? - VV Missing spare sprinkler heads If the ball drip valve drip sunder normal conditions, it is an indication that - /V the lower check valve is defective What is the function of the ball drip valve? - VV Prevents water from freezing in the siamese connections. Which of the following is most likely to be found at a loading dock which is unheated and generally unattended? - //Automatic Dry Sprinkler System To continue to burn a fire requires: - //Fuel, Heat and Oxygen What is the maximum amount of time that a fabric need NOT be re-flameproofed? - / V3 years How many times may a fabric be laundered before it is required to be re-flameproofed? - V/V No times. Which of the following is NOT true about cap colors of siamese connections? - /V Yellow means that there are both standpipes and non-automatic sprinklers. Which of the following is true about the main shut off valve of an automatic sprinkler system ? - v J Must be visually inspected weekly unless equipped with a temper switch. Which of the following SHOULD NOT be tested during Phase 2? - // Emergency Stop Button In case of fire, when directed by the Fire Safety Director what should the alarm box runner do? - VV Go to the nearest FDNY alarm box, activate the alarm, respond verbally if necessary, and wait for fire engines to arrive. Acontractor tells you that he has to turn off the sprinkler system in order to replace some sprinkler heads. Which of the following are you NOT required to notify? - /W FDNY High Rise Unit Allare true about smoke detectors EXCEPT - VV visually inspected monthly. All of the following must be done EXCEPT - / ¥ Operational test of portable fire extinguishers How often must activation of each manual sending station and verification of alarm receipt at the fire command station be done? - VV Semi-Annually (6 months) Instructions for range hoods should be kept - / Vin the kitchen at the entrance under glass Which is true about the portable fire extinguishers? - VV Inspected monthly, maintenance performed annually, hydrostatically tested every five or 12 years, depending on the type. All of the following must be checked monthly EXCEPT - / /Inspection/Cleaning of Range Hoods and Filters in Kitchens. "Fail-safe" stairway door locks ina Class E building must unlock - / every 4th floor During an inspection of the sprinkler system, you notice that the sprinkler heads in one of the tenant's areas have all been painted the same color as the ceiling. What should you do? - VV Have the sprinkler heads replaced. At what temperature range will a sprinkler head rated "ordinary" operate? - /V135-165° F Which statement is true ? - /VAscissors stairs has a standpipe at every other floor. At every elevator landing there must be a sign reading: - //'"In case of fire use stairs unless otherwise instructed" While conducting a test of smoke detectors on the 26th floor, you receive alarms from smoke detectors on the 1st and 2nd floors. What would be you best course of actions? - /V Acknowledge the first and second floor alarms and call in an alarm to the Fire Department. How often must fire drills be conducted in a new Class E building? - /V Every three months, for the first two years of occupancy. Every six months thereafter. The emergency generator must have enough fuel to supply the total emergency power load for at least - V¥ V6 hours Where must the lobby elevator ket switch be located? - /V No more than 4 feet from call button When are locks allowed on elevator door? - /V When locks can be operated by city-wide standard elevator key. (1620 and 2642) A Class E building has five tenants on each floor. Four have 7,500 sq. ft. each, the other has 22,500 sq. ft. How many fire wardens are required on the floor? - VV One for each 7,500 foot occupancies, and three for the 22,500 foot area. In an actual emergency, how would you evacuate a handicapped person? - / VTake him to a designated stairway. Which of the following keys should operate the smoke purge switch? - / ¥1620- under the direction of the Fire Department Incident Commander Which of the following is NOT true about the fire brigade? - VV They use fire hoses to fight fires. Local Law 5 is the NYC law that - V/V regulated office buildings. Which of the following should function during phase 1? - VV Safety Edge 10