Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

TCEQ IRRIGATION LICENSE STUDY GUIDE (QUESTIONS AND ANSWERS), Exams of Civil Engineering

TCEQ IRRIGATION LICENSE STUDY GUIDE (QUESTIONS AND ANSWERS) BPA requirements for fertilizer injection system - ANS-✔✔Reduced Pressure Principle Assembly (RPPA) (RPZ) is required when fertilizer injection are being used. Causes backsiphonage? - ANS-✔✔Caused by a negative or Sub-atmospheric pressure. Example-City departments are using fire hydrant or there's a city main line break, or someone sucking liquid from a glass using a straw. Causes of leaking check valve - ANS-✔✔Debris-can enter the valve. (Can use Y strainer to provide a solution.) Definition of high-hazard system? - ANS-✔✔Non-potable water, chemicals, fertilizers Definition of cross-connection? - ANS-✔✔Any actual or potential connection between a potable water supply and any source of contamination or pollution. Degree of hazard - ANS-✔✔A measure of the degree of risk or harm to the public's health. General installation requirements of BPA - ANS-✔✔Device must check/pass Back-siphonage, Backpressure, constant pressure, no

Typology: Exams

2024/2025

Available from 10/27/2024

passlist-passlist
passlist-passlist 🇺🇸

810 documents

1 / 3

Toggle sidebar

Related documents


Partial preview of the text

Download TCEQ IRRIGATION LICENSE STUDY GUIDE (QUESTIONS AND ANSWERS) and more Exams Civil Engineering in PDF only on Docsity!

TCEQ IRRIGATION LICENSE STUDY GUIDE (QUESTIONS AND ANSWERS) BPA requirements for fertilizer injection system - ANS-/ ¥ Reduced Pressure Principle Assembly (RPPA). (RPZ) is required when fertilizer injection are being used. Causes backsiphonage? - ANS-W ¥ Caused by a negative or Sub-atmospheric pressure. Example-City departments are using fire hydrant or there's a city main line break, or someone sucking liquid from a glass usinga straw. Causes of leaking check valve - ANS- Debris-can enter the valve. (Can use Y strainer to provide a solution.) Definition of high-hazard system? - ANS- & Non-potable water, chemicals, fertilizers Definition of cross-connection? - ANS-~ “Any actual or potential connection between a potable water supply and any source of contamination or pollution. Degree of hazard - ANS-V “A measure of the degree of risk or harm to the public's health. General installation requirements of BPA - ANS- / Device must check/pass Back-siphonage, Back- pressure, constant pressure, non-health hazard, health hazard. Installation requirements of AVB - ANS-/ /-Installed 6" above the highest head or outlet in the system. -No Valves -Downstream. -Installed vertically, Installation and inspection requirements for public water system to BPA - ANS-/Y