Typology: Exams
1 / 29
Trapped firefighters awaiting rescue will use less air if ANSWER: they control their breathing A closed circuit or "rebeather" type breathing apparatus uses a cylinder of in its operation. ANSWER: Oxygen The Primary function of the bypass valve on SCBA is: ANSWER: For use if the regulator fails The proper position of the bypass valve on positive-pressure SCBA under normal conditions is: ANSWER: Fully closed All SCBA regulators should ;be provided with a valve to be opened in the event of regulator failure. ANSWER: Bypass A firefighter is susceptible to poisoning or irritation from carbon monoxide through:
ANSWER: inhalation Which type of breathing apparatus recycles the users exhaled breath after removing carbon dioxide and adding supplement oxygen? ANSWER: Closed-circuit What are the two general types of self-contained breathing apparatus? ANSWER : open-circuit and closed-circuit On breathing apparatus equipped with a low pressure hose, the low-pressure hose brings air from the: ANSWER: Regulator to the face piece Which of the following is NOT a component of an open-circuit breathing apparatus? ANSWER: Oxygen cylinder Limitations affecting a firefighter's ability to use SCBA effectively are: ANSWER: Physical Medical
Mental ALL OF THE ABOVE When filling an SCBA cylinder, the cylinder must be Placed ANSWER:in a fragmentation containment or other shielded device PASS is an acronym for Safety System. ANSWER: Personal Alert An advantage of a face piece nosecup is that it: ANSWER:Helps control internal fogging Inhaled toxic gases can directly cause: ANSWER: Disease of the lung tissue SCBA should be used: Around hazardous materials During overhaul of fire scenes At confined space
rescues ANSWER: ALL OF THE ABOVE Which of the body's systems is most vulnerable to injury from the toxic conditions and gases encountered during firefighting operations? ANSWER:Respiratory Atmospheres are classified as oxygen deficient when they fall below percent oxygen. ANSWER: 19. Toxic substances found in smoke include: Carbon monoxide Carbon dioxide Tar ANSWER: ALL OF THE ABOVE Which of the following is NOT a characteristic of carbon monoxide?
1500 ppm ANSWER: It has a sharp pungent odor has the sole responsibility for testing and certification of respiratory protection including fire service SCBA. ANSWER:NIOSH The plan or written document for tactical operations is known as a department's: ANSWER: SOP/SOG Fire department standard operating procedures should be established in the MOST COMMONLY accepted order of fire ground priorities, which is? Life safety, incident stabilization, and property conservation Depending on a department's mission statement, a firefighter may also be required to perform in areas such as a(n): Hazardous material technician Rescue specialist Emergency medical technician or paramedic ALL OF THE ABOVE
Which of the following is NOT a requirement for an individual trained in fire suppression? Being certified as a pumper driver/operator Historically, the basic unit of a fire department is: The company Which of the following is NOT of the basic duties of an engine company? Performing specialized rescue One of the primary functions of the truck/ladder company is: Performing forcible entry to fire building Which of the following is NOT considered a function of the rescue company? Stretching the initial attack line The person ultimately responsible for the operation and administration of the fire department is the: Fire chief
In all fire departments, training must: Be a continuing function Which of the following terms DOES NOT 'relate to fire and emergency operations? Bylaws What is/are the rule(s) for developing standard operating procedures (SOPs)? Firefighter safety is the first consideration for all procedures SOPs should be brief, clear, and concise If an SOP doesn't work, change it ALL OF THE ABOVE Why have many departments adopted SOGs in lieu of SOPs? Guidelines are more flexible and useable by line officers The chain of command: Is the pathway of responsibility from the highest level of the department to the lowest.
related to the number of personnel an individual can effectively supervise. span of control Which of the following is NOT considered one of the basic tasks of the ladder company crew? Advancing hose lines to extinguish the fire An attack that uses the steam generating techniques of a ceiling-level attack, along with application of the fire stream on a material burning near the floor level, is know as a(n) attack Combination Firefighters should treat all downed wires as: energized Which of the following statements regarding preparing for an inspection visit is incorrect? Inspections are performed around firefighting schedules and not the schedule of the business owner NFPA 1001 is the: Standard for Fire Fighter Professional Qualifications
OSHA may establish regulations governing fire department activities such as health, safety A common factor with regard to recent multiple fire fighter deaths at emergency incidents is: The lack of an organized, effective common structure The leading type of death-producing injury in the fire service is: Heart attack What is the leading cause of firefighter injuries? Overexertion and strain How does OSHA look at NFPA standards when addressing issues NOT directly covered by the CFRs? NFPA standards are viewed as guidelines. Which of the following topics is NOT covered by NFPA 1500? Budgeting requirements
Which of the following items is NOT important when factored into the firefighter's safety equation? Gender Every skill, knowledge item, or behavior learned should be drilled, tested, or confirmed? Every year To ensure safety, team should: Look out for each other Work together and remain intact Utilize an Incident Management System ALL OF THE ABOVE Which of the following actions does NOT contribute to firefighter safety? Free-lancing Making equipment safe is addressed by: Selection
Inspection and maintenance Application ALL OF THE ABOVE A fire ground management system that addresses procedures for controlling personnel, facilities, equipment, and communications and is designed to be expanded as needed is the: Incident management system The coupling on the high pressure hose that is attached to an SCBA cylinder should be: Hand tight When using positive pressure SCBA, a poor seal between the face piece and the firefighter's face is: Dangerous, because it is still possible for toxic gases to enter the face piece All of the following are good practices when wearing self-contained breathing apparatus, except:
When tightening the straps on a SCBA face piece, the _ straps should always be tightened first. Lower As the oxygen supply in any given area falls below percent, unconsciousness can occur. 9 The FIRST noticeable sign of oxygen deficiency are: Increased respiratory rate and impaired muscular coordination Four hazardous atmospheres that firefighters are likely to encounter at a fire are super-heated air, toxic gases, oxygen deficiency, and smoke The open-circuit, positive pressure breathing apparatus operates by: maintaining a pressure inside the mask that is slightly higher than atmospheric pressure. Rescue from sewers, grain silos, and similarly confined spaces requires the use of self-contained breathing apparatus due to the danger of: Toxic gases and oxygen deficiency
PASS devices are designed to assist rescuers attempting to? locate trapped firefighters All breathing apparatus must be stored so that it is ready to be: donned and used Which of the following is NOT a limitation of an SCBA unit based on design and size?
What type of SCBA is MOST commonly used in the fire service? Open-circuit Which of the following statements regarding the two SCBA types in fire service is incorrect?
What is the FIRST step a firefighter should perform before donning the SCBA? check the air supply of the SCBA unit Firefighters should practice reduced profile maneuvers withSCBA, but they must realize that this procedure: Should be used as a last resort for an emergency escape from a hostile environment Which of the following is NOT a safety practice when riding on an apparatus?
NFPA requires that, as a minimum, PPE clothing should be cleaned every mont hs 6 Which of the following is NOT one of the components of the layered protection system in structural PPE?
The purpose for the use of reflective trim on PPE is to: increase the visibility of the wearer to others. Which of the following is NOT one of the advantages to wearing gloves that meet NFPA standards for structural firefighting?
Which of the following statements is incorrect?
When climbing a ladder, a firefighter's eyes should be directed: Forward and occasionally upward The fire service must be aware that synthetic materials used in buildings: Produce large amounts of toxic gas when burned After the face piece, low-pressure hose, and exhalation valve have been properly washed and disinfected, they should be: Air dried in a clean area Following each face piece of a breathing apparatus should be cleaned by: Washing with a mixture of warm water and approved disinfectant Recharging air cylinders can be done from a bank of large air cylinders. The system is called a(n) syste m. Cascade Inspecting an SCBA low-pressure hose for defects includes stretching the hose and: Checking for cracks
A fire department's comprehensive SCBA program should include: Inspecting, disinfecting, maintaining, and storing Defective SCBA cylinder units should be. Removed from service The must be stamped or labeled on a compressed air cylinder. last hydrostatic test date. Worn, damaged, and deteriorated parts of a SCBA must be replaced according to Manufacturer's instructions Composite SCBA cylinders must be hydrostatically tested every: 3 years Steel and aluminum cylinders for breathing apparatus should be hydrostatically tested after each year period five
Which of the following has the highest priority for a radio transmission?
self-help instructions intended to enhance the overall safety of the citizen until first responders arrive on the scene All of the following are considered valuable characteristics or traits for a person who receives emergency calls except:
the call should: Use plain everyday language With regard to all incomplete calls, the individual receiving the call should: Diligently follow up on all incomplete calls In fire departments that have access to multiple radio channels, fire ground operations should be: Assigned a separate channel dedicated for use on that scene only What is the largest difference between basic 911 and enhanced 911? Enhanced systems have the capability to provide the caller's telephone number and address. Which of the following is NOT one of the advantages of cellular phones on reporting emergencies? Callers are more likely to know exact location The primary disadvantage of the simplex radio system is the Limited range and interference between multiple units in same system What is/are the advantage(s) of the duplex radio system? Greater range and elimination