Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Virginia Hic Exam Questions With 100% Correct Answers | Verified | Updated 2024, Exams of Advanced Education

Virginia Hic Exam Questions With 100% Correct Answers | Verified | Updated 2024 The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs is - Correct Answer-1 1/4 inches What is the MINIMUM breaking strength required of safety belt lanyards - Correct Answer-5,400 pounds What is the MINIMUM clearance that combustible insulation MUST other heat-producing devices - Correct Answer-1 inch What is the MAXIMUM flame spread index for insulation materials - Correct Answer-25 The amount of water per sack of cement is what controls all EXCEPT - Correct Answer-Wear resistance The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of - Correct Answer-25 feet of the worker What is the correct sequence for installing a

Typology: Exams

2023/2024

Available from 07/18/2024

professoraxel
professoraxel 🇺🇸

3.7

(28)

10K documents

1 / 5

Toggle sidebar

Related documents


Partial preview of the text

Download Virginia Hic Exam Questions With 100% Correct Answers | Verified | Updated 2024 and more Exams Advanced Education in PDF only on Docsity!

Virginia Hic Exam Questions With 100%

Correct Answers | Verified | Updated

The MINIMUN length drywall screw for installing 1/2 inch gypsum board to wood studs is - Correct Answer-1 1/4 inches What is the MINIMUM breaking strength required of safety belt lanyards - Correct Answer-5,400 pounds What is the MINIMUM clearance that combustible insulation MUST other heat- producing devices - Correct Answer-1 inch What is the MAXIMUM flame spread index for insulation materials - Correct Answer- The amount of water per sack of cement is what controls all EXCEPT - Correct Answer- Wear resistance The escape device for a trench over 4 feet deep MUST be within a MAXIMUM of - Correct Answer-25 feet of the worker What is the correct sequence for installing a bi-fold door - Correct Answer-Top track, lower track, insert bottom pivot, insert upper pivot What is the MINIMUM height for a stairway handrail - Correct Answer-34 inches How MUST rafters be framed to each other - Correct Answer-With rectangular ties The nailing holes in aluminum and vinyl siding are elongated to allow for - Correct Answer-Expansion and contraction What are batter boards - Correct Answer-stakes and ledger boards marking building lines The first step that needs to be taken prior to starting any excavation work is - Correct Answer-contracting the local utility companies What is the MAXIMUM distance horizontal reinforcement can be placed from the top of a masonry partition wall - Correct Answer-16 inches What is the MINIMUM vertical reinforcement spacing for a reinforced concrete foundation wall that is 7 feet high and 10 inches thick on type SP soil - Correct Answer- 48 inches on center

A third stairway stringer should be used when the stair width exceeds - Correct Answer- 30 inches Unless otherwise specified, the standard guideline for spacing contraction joints is to space them in feet - Correct Answer-2 times the stab depth in inches What is the MINIMUM lap of riveted horizontal lap siding - Correct Answer-1 inches For multiple-width masonry (mampostería de ancho múltiple) what is the MINIMUM thickness of grout between masonry units and reinforcements? - Correct Answer-1/ inch What is the MAXIMUM dimension of the ventilation coverings for under-floor space - Correct Answer-1/4 inch The MOST specific information about the size and location of windows would be found in a - Correct Answer-Floor plan What is the MINIMUM illumination for general constructions area lighting - Correct Answer-5 foot candles in drywall 3 trim is used to - Correct Answer-provide a finish edge What is the MINIMUM number of anchor bolts REQUIRED for anchoring a 12 foot section of wood still plate to a foundation - Correct Answer-two bolts What is the MINIMUM square footage of net clear opening area for an egress window in a second floor sleeping area - Correct Answer-5.70 square feet Which window type consists of an upper and a lower sash that slide vertically in the side jambs - Correct Answer-Double hung windows Damp proofing on below-grade masonry foundation walls shall extend from the top of the footing to - Correct Answer-6 inches above the finished grade Scaffolds MUST remain a MINIMUM of how many feet from a 50-kV power line - Correct Answer-10 feet The REQUIREMENT for the thickness of masonry unit bed joints for the second course shall be - Correct Answer-3/8 inches What is not REQUIRED in exterior non bearing walls - Correct Answer-a singles flat 2" x 4 member for opening up to 8 feet wide What is the typical exposure of 3-tab asphalt shingles - Correct Answer-5 inches

A lengthwise grain separation between or through the growth rings of lumber is called a

  • Correct Answer-Shake What is the MINIMUM roof slope REQUIRED for modified biturmen roofing - Correct Answer-1/4 inch in 12 Flexible insulation placed in floor joists above an unheated crawl space should - Correct Answer-Be well supported between joists When lumber dries in tends to shrink - Correct Answer-More in width than length What is the MAXIMUM thickness for an 8 foot high hollow masonry foundation wall that is 4 feet below finish grade on the exterior - Correct Answer-8 inches When MUST a saddle be installed on a chimney - Correct Answer-When the chimney is greater than 30 inches wide What is the MAXIMUM recommended spacing for 5/8 inch drywall installed on a wall at right angies to framing members - Correct Answer-24 inches increasing the slump of concrete - Correct Answer-increases the wetness In a Vinyl soffit installation what type of accessory is used - Correct Answer-J & F Chanel In a crawl space how far from the floor joints do you need to place vapor retarder - Correct Answer-Top Soil What is the maximum lateral distance to egress when working in a trench? 10 - 15 - 25 - Correct Answer- What type of latex coating will not chalk when applied to exterior walls - Correct Answer- Latex Employee brought his own tools to work, who's responsible for the tools safety Employer or the employee - Correct Answer-employer What is the maximum thickness of bed joint - Correct Answer-3.8 joint What is first step in finishing concrete - Correct Answer-screeding Ice dam protection needs to be _________ from the edge of eaves - Correct Answer- inch Prior to the installation of wood floor how long for acclimation - Correct Answer-4-5 days

Where to install radiant heat barrier in attic - Correct Answer-Rafters High wind area how many fasteners per shingle - Correct Answer-6 fasteners what kind of siding can be vertically installed - Correct Answer-Panel Boarden space ties on concrete walls distance between ties - Correct Answer-24 inch When building a block foundation where does one start - Correct Answer-Corners What is the maximum area for a window glazing panel in a 1 hr fire rated door installation on interior wall - Correct Answer-100 sq A door frame consists of what parts - Correct Answer-one head, two sidejob What material is acceptable for valley on asphalt shingle roof installation - Correct Answer-mineral surfaced asphalt Guards on open sided walking surfaces need to be located more than________measured vertically to the floor - Correct Answer-6 feet what type of gypsum is used in veneer plaster system - Correct Answer-Blueboard Where do you art laying parquet flooring - Correct Answer-centerline The top of the ladder shall extend at least _______ above the edge of the roof - Correct Answer-3 feet about roof Concrete with a clump of 4" can be used for _______ - Correct Answer-flatwork The abbreviation "d" in "16d" means - Correct Answer-penny What is the purpose of a sash - Correct Answer-glazzing What is the major advantage of icynene over polyurethane foam - Correct Answer-Fast expansion What is the maximum threshold height for R-3 egress door (non sliding) - Correct Answer-1/2 inches Door casing should be - Correct Answer-Nailed to trimmer stud and then chalked to the wall When installing ceiling drywall, end butt joints should - Correct Answer-Be butted tightly

When installing a string of wall cabinets, the cabinets should - Correct Answer-Be attached to the adjacent cabinets before to the wall Which type of hydrated lime should be used for structural masonry wall - Correct Answer-type S Fiber cement siding for exterior weather wall, the minimum thickness should be - Correct Answer-0. For board and batten installation, how should batten be applied - Correct Answer- between joists What is the clearance for an exterior wood siding and finish grade where the wood is untreated - Correct Answer-8 inches