Architectural drawings, Study Guides, Projects, Research of Art

For art guide in drawings aspiring architects

Typology: Study Guides, Projects, Research

2025/2026

Uploaded on 01/25/2026

unknown user
unknown user 🇸🇬

1 / 9

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
pf3
pf4
pf5
pf8
pf9

Partial preview of the text

Download Architectural drawings and more Study Guides, Projects, Research Art in PDF only on Docsity!

WATERLINE LAYOUT (a) _|SOMETRIC DIAGRAM (27 Mis mast 0 soma eves - 8 ‘sono 0 aves TTT TALS T ] => > aK cig ‘OUTLET ; i TONEAREST ; Sewenun 5 l at Jeary) at e = al LOS Lf at ‘oy oP LEACHING CHAMBER l C cv Hee i (rveical) 70 r 10 Io oe [RIDE ERO OF GESTION De ren ae =| as sr (2 SEPTIC VAULT PLAN Pe 1:50MTS SANITARY (2) _|SOMETRIC DIAGRAM (27 MTs FIN, GRADE LINE FIN. GRADE LINE 150MMD PvCsP. 2 'W/2% SLOPE, = $ a TI INLET \ 16 Ma HOA, BARS Fy @ 250MMOC. & IGESTIOK 16 Mi VERT. BARS @ #300 MMO.C. (TYP) st 18 MMO EXTRA BARS ores #600 MM 0.6 16.04 0 BARS AT 259 MMO.c, wo ‘CUT-OFF ALTERNATE @ 452 Mu FROM FACE OF SUPPORT 16 MMC LONGITUDINAL ‘BARS AT 269 MMO.C. (SEPTIC VAULT SECTION DETAIL 14 (P27 1:50 MTS 8 STORM DRAIN rf] 3) ISOMETRIC DIAGRAM P2 MTS 150 MM PVCSP on W/2% SLOPE (INLEN, FINISH GRADELINE ad 2 800_ HEAVY DUTY BRASS CO Fj ‘COVER(TYPICAL) ET fy ef ‘=F i cl le] Drs oUBER ASE 8 temmaextra_/ BARS AT 4-600 MMOL, SMM BARS AT259 MO. CUT-OFF ALTERNATE @ 462 WMI FROM FACE OF SUPPORT dia a 150MM THK. RC. WALL WITH 18MM G HOR. BARS AT 2504M (0.C. AND 16 Mido VERT. BARS ‘AT #300 MMO.C. (TYPICAL) 150 MM THK. BOTTOM ‘I eR) ‘COMPACTED GRAVEL cr (@\ SEPTIC VAULT SECTION DETAIb, 2 P27 1:50 MTS REPUBLIC OF THE PHILIPPINES DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS. PROUECT NAME AND LOCATION, SHEET CONTENTS: (CONVERGENCE AND SPECIAL SUPPORT PROGRAM - BASIC INFRASTRUCTURE PROGRAM (3IP)- CAVITE 3RD DISTRICT ENGINEERING OFFICE CARMONA, CAVITE ZAPOTE 5), BAGOOR CTY, CAVITE Eaaae ISOMETAIG DIAGRAMS suBMiTTED: recom ; SOMMENDED: SET NO. SHEET No. SEPTIC VAULT DETAILS heenapeery = PREPARED: a PAUL GAap€L c. DONES ae ax woe ro =a See Sa? eg (> STORM DRAIN LAYOUT Nay 1:100 MTS pccepererar a SHED STORM DRAIN (2> 'SOMETRIC DIAGRAM 37 MTs \ je \ REPUBLICOF THe PALIPTRIcE PROJECT NAME AND LOCATION: SHEET CONTENTS reves) +) —_—| suawrrep————_ -_[ necomenoeo wernoven, ||| seine. | sieervo, DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS REGINA CONVERGENCE AND SPECIAL SUPPORT PROGRAM |” SHED STORM DAAINAGE LAYOUT 4 BASIC INFRASTRUCTURE PROGRAW (I) SHED ISOMETRIC DIAGRAM nee € CAVITE SRD DISTRICT NULT: PURPOSE BUILONGSIPACILITIS TO SUPPORT ra mGaeuig(n si iFeR FA Don Cuma Foe DNGINEERING OFFICE SOGIAL SERVICES CONSTRUCTION (COMPLETON) OF ‘CARMONA, CAVITE MULTLPURPOSE BUILDING, 2APOTE 3 (FORMERLY 2APOTE 5}, BACOOR CITY, CAVITE Pau. oARiEgeroONES Ko 2 MDP ENCLOSURE 2 NEMA LOCATION 2 GROUND FLOOR TAMPERE KT yout PROTECTION WIRES (THAN) yNDUIT LOAD DESCRIPTION voLT LOAD nOrECTO pasa! Sen NO AWPERE| ‘PHASE [ AT [AF] P [RAC] UNE | GROUND | PVC 1 LIGHTING LOAD zo] 1600 [696 | 20 | 50 | 2 | 10 | 235mnP E Zone 2 CONVENIENCE OUTLET 230 wo _[ 626 | 20 | 50[ 2 | 10 | 235mm | 1-3.5mm? | 20mmaC 3_| CONVENIENCE OUTLET z0_[ toe [470 [20 | 50 | 2 [ 10 | 235mm? | 135mm? | 20mmac 4 CONVENIENCE OUTLET. 230 1260 [548 [ 20] 50 [ 2 [ 10 | 235mm | 135mm? | 20mmac oO ACU 1 -3.0H.P z0_| aso | 17.00 [40 | 50 | 2 | 10 | 2s.smm? | 1-3.5mm? | 20mmac 6 ‘ACU 2-3.0HP zo | 3910 | 1700 [ 0 | 50] 2 | 10 | 256mm | 135mm? | 20mmac 7 ‘ACU 3 -3.0HP zo | 3e10 [1700 [40 | 50 | 2 | 10 | 256mm | 135mm? | 20mmoc 8 CCTV AND FDAS 20 | 1000 | 435 | 20 | 50] 2 | 10 | 235mm? | 1.3.5mm? | 20mmac TOTAL CONNECTED LOAD rao | 7874 resoas = (7874)(80}+(0.25N17) NOTE : Al branch CB's should be commercial bolton = 67.24 Amps use industrial type CB for motor loads. USE 2-30,0mn? THHN & 1-8 Om? THHIN IN 32mm@ RSC MAIN ‘00AT, 100AF, 2P, 230, 1BKAIC, C.. 1 \ ELECTRICAL SCHEDULE OF LOADS Nor 70 ‘SCALE YANDRCAL DONNA, SURFACE MEUNTED eae verre Beprmee aml (C4) LIGHTING INSTALLATION DETAILS INCOMING POWER 2.90.0mm THAN & 1-8.0rin? THHN JGROUNO, STRANDED WIRE IN 2mm@ RSC PIPE 230V, 1PHASE, 60H DIGITAL WATT-HOUR METE} o0ar,2P230¥ MANUAL TRANSFER TO SERVICE PROVIDER POWER SERVICE HEAD = EYEBOLT I (ryeIcaL) | wae 43 ‘ 1 -8.0mmF THHN IN 20mmd C. - ios GROUND FLOOR, EAM Rees | RORRETTRETO Bea EIS 3 —s maaan ‘3000mm COPPERCLAD SERUOE ETE FOST ‘GROUND ROD GROUND ROD GROUNDING ELECTRODE SOALE (2 SINGLE LINE DIAGRAM Eyer 77 (C3 ELECTRICAL RISER DIAGRAM NOT E-2 70 SOME = —— l seaivam™ | |_[-—— Site pee [ienese eoncsma concen ty. i aries EMERGENCY LIGHT INSTALLATION DETAILS (8 \ OUTLET AND SWITCHES INSTALLATION DETAILS aN E2 J wo 70 SCALE NOT To SCE Nez NOT 70 SOHLE \ REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: (SHEET CONTENTS: Ra revewes) [SuBMIrTED. RECOMMENDED: aperoven | Z| seine [sveerne DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS. 2 REGION IV-8 CONVERGENCE AND SPECTAT SUPPORT PROGRAM - BASIC] ELECTRICAL SCHEDULE OF LOADS. EIR. PAS ny INFRASTRUCTURE PROGRAM (2IP) MULTI-PURPOSE | ShiGlE INE DIAGRAM A F = (==> BUILDINGSIFACILITIES TO SUPPORT SOCIAL SERVICES CAVITE 3RD DISTRICT “CONSTRUCTION (COMPLETION) OF MULTIPURPOSE | RISER DIAGRAM = PrREr REL: ARSE he ENGINEERING OFFICE BUILDING, ZAPOTE 3 (FORMERLY ZAPOTE 5), BACOOR CITY LIGHTING INSTALLATION DETAILS "ASSISTANT DJSTRICT EF ‘DISTRICT ENGINEER Ey, By oneces oni CATE EMERGENCY LIGHT INSTALLATION DETALS Fn ies ty) shut OUTLET AND SWITCHES INSTALLATION DETAILS. mice Rie T T = see &B | ¥ Ic a) LEGEND MAK EF PROPOSED SERVICE ENTRANCE. 2118 WTS LED WEATHER PROOF FIXTURE ELECTRICAL SITE DEVELOPMENT aN ey ‘SCALE NTS REPUBLIC OF THE PHILIPPINES DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS. REGION IV.A, CAVITE 3RD DISTRICT ENGINEERING OFFICE CARMONA, CAUTE proer ane oor seecrcowrenre 2 Ravens) a recone womans | TY were [eweeTno BUILDING, ZAPOTE 3 (FORMERLY ZAPOTE 5), BACOOR CITY, ae sia Laetitia iy GENERAL NOTES AND SPECIFICATIONS 4: 12. CONTRACTOR IS ADVISED TO VISIT AND SURVEY THE PLACE OF INSTALLATION. ALL AIR CONDITIONING UNITS AND VENTILATING UNITS TO BE SUPPLIED SHALL BE NEW AND APPROVED PRODUCTS OF REPUTABLE MANUFACTURERS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE CLOSELY HIS WORK WITH THE OTHER TRADES CONCERNED. REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 25 mm THICK PREMOULDED ELASTOMERIC RUBBER INSULATION AS MANUFACTURED BY “ARMAFLEX' AEROFLEX OR APPROVED EQUAL. INDIVIDUAL WEATHER PROOF TYPE CIRCUIT BREAKER SHALL BE PROVIDED PROVIDED FOR ALL CONDENSING UNITS. ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH INSULATION TYPICAL TO REFRIGERANT PIPING. (REFER TO PIPE INSULATION DETAIL.) ALL EXPOSED DRAIN LINES TO THE CEILING SHALL BE PROVIDED WITH INSULATION TYPICAL TO REFRIGERANT PIPING.(REFER TO PIPE INSULATION DETAIL.) ALL NECESSARY GOVERNMENT PERMITS SHALLBE § SECURED AND FOR ACCOUNT OF THE CONTRACTOR, AS-BUILT PLANS SHALL BE PROVIDED BY THIS CONTRACTOR AFTER COMPLETION OF = WORKS. ALL INSTALLATION WORKS SHALL BE DONE IN A NEAT AND WORK- MANLIKE MANNER. ALL REFRIGERANT SUCTION LINES EXPOSED INDOORS AND/OR EXPOSED TO WEATHER SHOULD BE PROVIDED WITH GAUGE #24 ALUMINUM CLADDING. (SUBMIT SHOP DRAWING PRIOR TO INSTALLATION) ALL ACCU's AND FCU's SHALL BE PROVIDED WITH ANGULAR BAR SUPPORTS. (SUBMIT SHOP DRAWING PRIOR TO INSTALLATION) LEGENDS AND SYMBOLS: (@}m FAN COIL UNITS AIR COOLED CONDENSING UNITS GROUND FLOOR (4. ACU LAYOUT SCHEDULE OF SPLIT TYPE AIR CONDITIONER © ©® MOP) @® pews = acianet| SECOND FLOOR (2 \ACU LAYOUT So THIRD FLOOR (3. \ ACU LAYOUT \ME-1/ = 4100 Ww INDOOR UNIT REMARKS: COOLING CAPACITY FCU-1 FCU-3 ELECTRICAL DATA ALL UNITS SHALL BE BRAND NEW & DESIGNATION | QTY. 1 BTU/hr kJ/hr POWER INPUT (kW) | EER FCU-2 3 20,500 | 21,600 | 295 x 990 x 266 6.0 9.8 7 CURRENT (Ay STARTING | RUNNING [VOLTS] PHASE COMPLETE ELECTRONIC (REMOTE)CONTROL HERTZ WITH STANDARD ACCESSORIES, READY FOR SERVICE, 60 NOTE : ALL FAN COIL UNITS (FCUS) SHALL BE PROVIDED WITH EVAPORATOR DRAIN PIPE, OUTDOOR UNIT COMPRESSOR | ] DESIGNATION | QTY. Type | ary. FAN MOTOR OUTPUT PIPING CONNECTIONS REFRIGERANT MAX LENGTH (m)]LIQUID (rmm)] GAS (mm) ACCU-1 | ACCU -2 | 3 HERMETIC. ACCU -3 SCROLL 3 695 x 930 x 350 30 6.408 12.78 WEIGHT LOCATION (hg) GROUND FLOOR 44 SECOND FLOOR THIRD FLOOR REPUBLIC OF THE PHILIPPINES PROJECT NAME AND LOCATION: SHEET CONTENTS: ao SUBMITTED. = TZ [= ‘SHEET NO. DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS REGION V.A TAC SUPPORT PROGRAM BRET SRVERGENCE AND SPECT INFRASTRUCTURE PROGRAM (BIP) - MULT-PURPOSE BUILDINGSIFACILITIES TO SUPPORT SOCIAL SERVICES ‘CONSTRUCTION (COMPLETION) OF MULT-PURPOSE BUILDING, ZAPOTE 3 {FORMERLY ZAPOTE 5}, BACOOR CITY| CAVITE, CAVITE 3RD DISTRICT ENGINEERING OFFICE WED) YESS! TECENDS AD ruBCLS AOE (GROUND FLOOR ACU LAYOUT PREPARED: ‘SECOND FLOOR ACU LAYOUT THIRD FLOOR ACU LAYOUT CARMONA, CATE SCHEDULE OF EQUIPMENTS eh { with a I a rSTION oe Uh WY Ce a B, T F y MOUNTING BOLT Me<25 WT RUBBER ANTL-VIBRATION DISK AND, [NUT MB WITH NO. 8 (8) WASHER NO. (4 ACCU MOUNTING DETAIL ENCLOSED ORCUT BREAKER, INHER ECLOSIRE (SUES ERUED) eri Mmm SPACE {WITH EQUPHENT SUPPLIER ‘EQUIPMENT BASE AGU NEOPRENE VB Iseustor =— FEATURES. TWRELESICORENOTECOMTCUER 2 aleeausres WALL MOUNTED FCU. {INDOOR UNIT) CONCRETE BOLT ST) WTHND 818) Waste no WASHER 1) 80 NLONPWS if TOWASHER (4) Leonor preto CGRCUTHEMERUN (SZEASREQURED) FIN, FLOOR LINE. Leu 270m ORAS PER ARGHTECT CALVANIZED IRON GAUGE @20 WEATHER METAL SCREW WITH EXPANSION SHIELD (TYPICAL) (2 FCU MOUNTING DETAIL ME-2 EXPANSK TOOMM CHANNEL, 12MMg. HANGER 1oMMe NUT & NOT To CONCRETE SLAB ON BOLT ROD Y BOLT W/ WASHERS SUCTION UNE: (3 \ PIPE HANGER DETAIL SCALE NoT ME-2 INSULATION REFRIGERANT PIPE To SCALE (3 PIPE THRU F BOX WITH EPOXY PAINT BY MECHANICAL CONTRACTOR ‘SUCTION. LINE WITH INSULATION CONCRETE SLAB ANG su ULAR BAR IPPORT (TYP) ME-2 ALUMINUM METAL JACKET FOR PIPING EXPOSED IN OUTDOOR LOCATION 6mm BOLT & NUT WITH LOCK WASHER GAGE 16x25mm ALUMINUM STEEL BOND 6 \ PIPE INSULATION DETAIL NOT 7 PVC_PIPE: SLEEVE CONCRETE WALL, BY CIVIL CONTR—J LOOR DETAIL SCALE WATERPROOF. HEAT RESISTANT CAULKING COMPOUND ALL AROUND PIPE ( TYPICAL ) QUID LINE Je SEALED ALL AROUND: WHERE PIPE IS EXPOSED Ss Ber I SUCTION LINE REFRIGERANT PIPE INSULATION AS PER ‘SPECIFICATION ON PVC PIPE SLEEVE CONCRETE WALL—t BY CML CONTR NOUIT PII | —conour PIPE LIQUID. LINE SUCTION LINE REFRIGERANT PIPE INSULATION AS PER ‘SPECIFICATION (1 REFRIGERANT PIPES THRU WALL DETAIL (8 \ REFRIGERANT PIPE INSULATION ELEVATI ON CONDENSATE DRAIN’ PAN REFRIGERANT COPPER PIPE TYPE "L” NOTE: CAPPED TEES FOR ALL ELBOW MECHANICAL CONTRACTOR (HVAC) SHALL BE FURNISH ‘AND INSTALL ALL CONDENSATE DRAIN PIPING FROM COOLING COIL DRAIN PAN TO NEAREST FLOOR DRAIN “AT EQUAL TO OR LARGER THAN THE PLENUM NEGATIVE STATIC PRESSURE AT DESIGN OPERATING CONDIONS. “BY MUST BE EQUAL TO OR LARGER THAN 1/2 THE PLENUM. MAXIMUM NEGATIVCE STATIC PRESSURE. “C” EQUAL TO MAXINUM NEGATIVE STATIC PRESSURE IN THE PLENUN, CONDENSATE TRAP (4 CONDENSATE DRAIN PIPING DETAIL TO NEAREST DRAIN ee MEQ] Nor POLYETHYLENE, BLUE FILM TAPE. VAPOR. BARRIER 25 mm. THICK PRE-FORMED THERMAL ELASTOMERIC CLOSED CELL TUBE INSULATION HO NOTES 1 DO NOT EXCEED MAXIMUM PIPE DISTANCE, REFER TO EQUIPMENT MANUFACTURER'S TABLE TO SCALE REFRIGERANT COPPER PIPE TYPE “L” HD ‘DISCHARGE PIPE ME2/ Nor To ‘SCALE ME2/ Nor TO SCALE NUS) NOT To ‘SCALE (WEZ/ NOT 70 SCALE = — DEPARTARERUBLIC OF THE PHILIPPINES | [PROJECT NAME ANO LOCATON [SHEET CONTENTS: essere ZZ revenso—) 7) SUBMITTED: RECOMMENDED: ‘APPROVED: Il setno, | sheerno. react Sees su sele She RRCeEIRoanl Peeee anTiD Ga ease ar mnatecmia ma 4 TE NE | a aN CE A REFSERAT (ane CAVITE 3RD DISTRICT BULDNGSFACKTIES TO SUPPORT cOCIA SERVICES | Fea FLOORDETAL _ REFIGERANT PPE NSLLATION REFTRES a Co=\\Ce ENGINEERING OFFICE BUILDING, ZAPOTE 3 (FORMERLY ZAPOTE 5), BACOOR ciTy | CONDENSATE DRAIN DETAIL = Pere Kos CARMONA, CATE PIPE INSULATION DETAL,