1. T
he special inspector shall furnish daily inspection reports to the
and
:
Building
oflcial
and
Registered
design
professional
2. According to the Specifications for Structural joints, how can high
strength bolts and nuts be identified on a job site?: Bolt and nut
markings
3. Who shall the special inspector demonstrate competence to?:
Building Oflcial
4. Who is responsible for preparing the statement of special
inspection?: Regis-
tered design professional
5. According to the Specifications for Structural Joints, where twist-off
tension control bolts are used, what field inspection is of primary
importance for joint strength?: Bolt length
6.
The Special inspections required by this code are not required
where the
work is done on the premises of a (an):: Approved
fabricator
7. Th
e type and extent of each special inspection shall be located in
:
The
statement of special inspection
8.
When tension-control bolts are used, and F436 was her
shall be used under the
: Nut
pf3
pf4
pf5

Partial preview of the text

Download Bolting Test #1 updated correctly answered and more Exams Advanced Education in PDF only on Docsity!

1 /

Bolting Test #1 updated correctly answered

1. T

he special inspector shall furnish daily inspection reports to the and : Building oflcial and Registered design professional

  1. According to the Specifications for Structural joints, how can high strength bolts and nuts be identified on a job site?: Bolt and nut markings
  2. Who shall the special inspector demonstrate competence to?: Building Oflcial
  3. Who is responsible for preparing the statement of special inspection?: Regis-tered design professional
  4. According to the Specifications for Structural Joints, where twist-off tension control bolts are used, what field inspection is of primary importance for joint strength?: Bolt length
  5. The Special inspections required by this code are not required where the work is done on the premises of a (an):: Approved fabricator
  6. Th e type and extent of each special inspection shall be located in : The statement of special inspection
  7. When tension-control bolts are used, and F436 was her shall be used under the : Nut

2 /

  1. Who can hire a special inspector?: Owner's agent
  2. When discrepancies go uncorrected and a correction notice is issued, who must be notified?: City inspector and Registered design professional
  3. Faying surfaces and surfaces adjacent to the bolt head and nut shall be : Free of dirt and other foreign material
  4. A bolted connection designed to resist movement by friction on the faying surface of the connection under clamping forces of the bolts is what type of connection.: Slip Critical
  5. Bolts, nuts, and washers.....: Must be kept in protective storage
  6. A bolt calibration device is required for pre-installation testing whenev-er......: • Slip critical joints are being used
  • Pretensioned joints are being used
  • When the calibrated wrench method of installation is being used
  1. Pretensioned joints are only required in the following applications ex-cept....: Joints that are subject to fatigue load with reversal of the loading direction
  2. According to the Specifications for Structural Joints, where calibrated wrench pretensioning is used, how often is the installation wrench to be calibrated by testing in a tension calibrator?: Daily
  3. Who is required to receive the final report?: Building department
  4. A ccording to the Specification for Structural Joints, not fewer than

4 /

  1. According to the Specification for Structural Joints, when bolts are installed with direct-tension indicators, they are verified for the correct tension by.....: - Measuring the gap between the direct tension indicator and the bolt head
  2. According to the Specification for Structural Joints, what additional inspec-tion is required for a slip critical joints?: Checking the condition of faying surfaces
  3. What is the maximum diameter anchor rod hole allowed in a 1-3/4 in. thick base plate for a W14 x 211 column that will be anchored with 1 inch diameter anchor rods?: 1 - 13/16 in.
  4. According to the Specification for Structural Steel Buildings, ASTM Standard is to be used for the material tests to determine the type of structural steel consisting of hot-rolled structural shapes.: A
  5. What is the flange width of a W14 x 211: 15 - 3/4 in.
  6. Accor ding to the Specification for Structural Steel Buildings, sample for hot-rolled steel would not apply to ashapes: ASTM A
  7. What is the nominal weight of an HSS 9x5x1/2 in. ?: 41.91 lbs./ft.
  8. What is the ASTM designation for flat circular washer?: F
  9. What is the web thickness for a WT15 x 146?: 1 in.
  10. A MC12 x 40 has a flange width of?: 3.89 or 3-7/
  11. What is the web thickness for a W33 x 291?: 15/16 in.
  12. According to the AISC Steel Construction Manual, the

5 / recommended maxi-mum size of anchor-rod hole in a base plate for a 1-inch diameter anchor-rod is inches: 1- 13/

  1. What is the web thickness in inches of a C8 x 18.7?: 1/2 in.