Bosch solution 6000 cheat sheets, Exams of Voice

Setting up a door for access only. • Assign user to a door/s. Menu 145. • Untick “reader area control”. Menu 614. • Assign reader/keypad to a door ...

Typology: Exams

2021/2022

Uploaded on 07/05/2022

allan.dev
allan.dev 🇦🇺

4.5

(86)

1K documents

1 / 10

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Bosch solution 6000 cheat sheets
Adding a token to a user
Select add token and user if prompted by keypad select reader Menu 120
Select door/s that the user will have access to (if applicable) Menu 145
Select areas that the user will belong to Menu 141
Adding a keyfob
Enable the receiver - Select option 4 bosch serial receiver Menu 350
Select add keyfob and select user, then enter 9 digit code Menu 130
Select areas that the user will belong to Menu 141
Adding a Fingerprint
Select add a fingerprint Menu 180
Select door/s that the user will access to(if applicable) Menu 145
Select area's that the user will belong to Menu 141
Setting up a door for access only
Assign user to a door/s Menu 145
Untick “reader area control” Menu 614
Assign reader/keypad to a door assignment Menu 617
Set output to required function (e.g. 60 Door) Menu 411
Select event assignment (door Name) Menu 412
Select output polarity (e.g. Open one shot low = 4) Menu 413
Set time parameter for the output (e.g. 10sec) Menu 414
Set any options required for the output Menu 415
pf3
pf4
pf5
pf8
pf9
pfa

Partial preview of the text

Download Bosch solution 6000 cheat sheets and more Exams Voice in PDF only on Docsity!

Adding a token to a user

 To open door press 5 and ok.

Communications setup

Tx 1 used for the e.g.

  •  Select add token and user if prompted by keypad select reader Menu
  •  Select door/s that the user will have access to (if applicable) Menu
  •  Select areas that the user will belong to Menu
  •  Enable the receiver - Select option 4 bosch serial receiver Menu Adding a keyfob
  •  Select add keyfob and select user, then enter 9 digit code Menu
  •  Select areas that the user will belong to Menu
  •  Select add a fingerprint Menu Adding a Fingerprint
  •  Select door/s that the user will access to(if applicable) Menu
  •  Select area's that the user will belong to Menu
  •  Assign user to a door/s Menu Setting up a door for access only
  •  Untick “reader area control” Menu
  •  Assign reader/keypad to a door assignment Menu
  •  Set output to required function (e.g. 60 Door) Menu
  •  Select event assignment (door Name) Menu
  •  Select output polarity (e.g. Open one shot low = 4) Menu
  •  Set time parameter for the output (e.g. 10sec) Menu
  •  Set any options required for the output Menu
  •  Assign user to a door/s Menu Setting up a door & User with arm, disarm & badging required
  •  Select reader & enable all on & disarming allowed. Menu
  •  Select reader and enable reader badging (& egress if required) Menu
  •  Select reader and enable reader area control Menu
  •  Assign reader/keypad to a door assignment Menu
  •  Set output to event type 60 Door Menu
  •  Select event assignment (door Name) Menu
  •  Select output polarity (e.g. Open one shot low = 4) Menu
  •  Set time parameter for the output (e.g. 10sec) Menu
  •  Set any options required for the output Menu
  •  Select options for reader/keypad (e.g.; arm/disarm/part) Menu Setting up a door with D.O.T.L triggering an output
  •  If required Select reader badging & reader area control Menu
  •  Assign reader/keypad to a door assignment Menu
  •  Set output to required function (e.g. 60 Door) Menu
  •  Select event assignment (door Name) Menu
  •  Select output polarity (e.g. Open one shot low = 4) Menu
  •  Set time parameter for the output (e.g. 10sec) Menu
  •  Set any options required for the output Menu
  •  Select a zone for D.O.T.L function in pulse count ( 13 ) Menu
  •  Set D.O.T.L time frame in pulse count time Menu
  •  Select the door the the D.O.T.L will work with Menu
  •  Set report route in Menu
  •  Set alarm condition if required for door forced Menu
  •  Select output type 61 D.O.T.L alarm Menu
  •  Select the door the D.O.T.L is operating on Menu
  •  Set output polarity for the output. Menu
  •  Set time parameter for the output Menu
  •  Select output options for the output Menu
  •  Assign user to a door/s Menu Access control with time zones
  •  Assign user to a time zone (e.g. time zone 2) Menu
  •  Assign reader/keypad to a door assignment Menu
  •  Select options for reader/keypad (e.g.; arm/disarm/part) Menu
  •  If required Select reader badging Menu
  •  Set output to required function (e.g. 60 Door) Menu
  •  Select event assignment (door Name) Menu
  •  Select output polarity (e.g. Open one shot low = 4) Menu
  •  Set time parameter for the output (e.g. 10sec) Menu
  •  Set any options required for the output Menu
  •  Select door options in Menu
  •  Select name for time zone Menu
  •  Set time frame that the user will have access (e.g. 9am-5pm) Menu
  •  Set the days that the time zone will be active Menu
  •  Assign user to a door/s Menu Access control with door auto open/close
  •  Assign reader/keypad to a door assignment Menu
  •  Select options for reader/keypad (e.g. arm/disarm/part) Menu
  •  If required Select reader badging Menu
  •  Set output to required function (e.g. 60 Door) Menu
  •  Select event assignment (door Name) Menu
  •  Select output polarity (e.g. Open one shot low = 4) Menu
  •  Set time parameter for the output (e.g. 10sec) Menu
  •  Set any options required for the output Menu
  •  Select unlock time zone for door (e.g. time zone 2) Menu
  •  Select door options in Menu
  •  Select name for time zone 2 Menu
  •  Set the unlock time period for the door Menu
  •  Set the days that the time zone will be active Menu
  •  Select desired output & select event type 58 time zone Menu Using outputs with time zones
  •  Select output event assignment (e.g. time zone 2) Menu
  •  Select output polarity Menu
  •  Select output time parameter Menu
  •  Select time zone and set time frame for that time zone Menu
  •  Select the days of the week that the time zone will operate Menu
  •  Set user pin length to “0” ( 0 = variable ) Menu Operating a door with a single digit code
  •  Set user 10 pin code to 5 Menu
  •  Set user 10 Area assignment to no area Menu
  •  Set output 5 to event type 56-follow pin Menu
  •  Set output 5 to 10 in event assignment-( 10 =this user ) Menu
  •  Set output 5 to 4 = ( normally open one shot low ) Menu
  •  Set output 5 to 000 000 005 000 ( 5 seconds ) Menu
  •  Enable output 5 to display status message Menu
  •  Select zone and set to Display only ( 14 ) Menu Setting up an Request to exit zone.
  •  Select an area for the zone Menu
  •  Select the door that the zone belongs to. Menu
  •  Select Tx 1 and set to contact id (default is C.I.D) Menu Contact ID
  •  Enter account number per area Menu
  •  Enter base station numbers Menu
  •  Test report period Menu
  •  Test report route Menu
  •  Open/close route Menu
  •  Report route(per zone) Menu
  •  Status route (system events E.g. low battery, ac fail) Menu
  •  Emergency route (keypad fire, panic, medical) Menu
  •  Select Tx 1 and set to GSM contact id (default is C.I.D) Menu Contact ID using GSM
  •  Enter Account number per area Menu
  •  Enter base station numbers Menu
  •  Test report period Menu
  •  Test report route Menu
  •  Open/close route Menu
  •  Report route (per zone) Menu
  •  Status route (system events E.g. low battery, ac fail) Menu
  •  Emergency route (keypad fire, panic, medical) Menu
  •  Select Tx 1 and set to sms Menu SMS
  •  Enter mobile phone numbers in Menu
  •  Test report period Menu
  •  Test report route Menu
  •  Open/close route Menu
  •  Report route (per zone) Menu
  •  Status route (system events E.g. low battery, ac fail) Menu
  •  Emergency route (keypad fire, panic, medical) Menu
  •  Select Tx1 and set to GSM SMS (12) Menu SMS using GSM
  •  Enter mobile numbers in Menu
  • number/s that you will be sending the command from. Menu  To use SMS commands to control the system enter the mobile
  •  Test report period Menu
  •  Test report route Menu
  •  Open/close route Menu
  •  Report route per zone Menu
  •  Status route (system events E.g. low battery, ac fail) Menu
  •  Emergency route (keypad fire, panic ,medical) Menu
  •  Default panel to domestic dial (only effects comms programming) Menu Domestic dial
  •  Enter phone numbers in Menu
  •  Home area Menu Commonly used locations
  •  Home area only Menu
  •  Add token Menu
  •  Add key fob Menu
  •  Display area icons Menu
  •  Enable Bosch R.F receiver (option 4) Menu
  •  Turn off part arm via key fob Menu
  •  Turn off audible key fob panic Menu
  •  Zone array Menu
  •  Operate output manually Menu
  •  Output array Menu
  •  Panel tamper options Menu
  •  Lan scan Menu
  •  E.O.L value Menu
  •  Disable dialler Menu
  •  Service interval Menu
  •  Monitor default pin Menu
  •  First to open/last to close Menu
  •  Rf beep volume Menu
  •  Test report time Menu
  •  Test report period Menu
  •  Test route Menu
  •  Time/date Menu
  •  Speaker beeps via key fob Menu
  •  Strobe flash via key fob Menu
  •  Set chime zones Menu
  •  Chime mode Menu
  •  Chime mode on ( Press and hold the 4 key) to toggle or use Menu
  •  Zone silent alarm Menu
  •  Invert zone seal Menu
  •  Zone test on exit Menu
  •  Service mode Menu
  •  Start direct link Menu
  •  Dial number test Menu
  •  History log Menu
  •  System trouble Menu
  •  Open close after alarm Menu
  •  Cancel reports Menu
  •  Battery test Menu
  •  Open/close reports (per user) Menu

 System Components

Expansion modules

 CM101B voice module  CM195B Multi RF receiver interface  CM704B 8/16 zone input expander  CM705B universal expansion module  CM707B piggy back zone input expander (used with CM705B)  CM710B 4 way relay output module  CM720B 1 amp power supply module  CM743B GSM/GPRS 2G plug on module  CM751B TCP/IP interface module  CM760B Real time clock module  CM797B LAN isolator module

Accessories

 SW500B Solution link software  SW501B Site manager software ( customer software )  CM900 Direct link cable  CM901 Firmware upgrade cable  CM255 Default key module (one time use only)  CM940B 6 way programmable relay card. (Can be separated into single cards )