Sampling plastic concrete Answer: Pass receptacle through discharge
stream or divert stream into sampling container
Grab samples for uniformity testing Answer: 3 grab samples required
Sample size for casting 3 100mm x 200mm cylinders Answer:
Minimum 20L sample size needed
Sample size for casting 150mm x 300mm cylinders Answer:
Minimum 30L sample size needed
Sample size for casting 150mm x 150mm x 535mm beams Answer:
Minimum 55L sample size needed
Extra sample for more than 3 cylinders/specimens Answer: Volume
of cylinders/specimens plus 10% extra needed
Time for obtaining, transporting, and remixing sample Answer:
Allowed 10 minutes for the process
pf3
pf4
pf5

Partial preview of the text

Download CCIL PRACTICE TEST PRACTICE SCRIPT UPDATED 2026 TESTED SOLUTIONS and more Exams Nursing in PDF only on Docsity!

CCIL PRACTICE TEST PRACTICE SCRIPT

UPDATED 2026 TESTED SOLUTIONS

⫸ Sampling plastic concrete Answer: Pass receptacle through discharge stream or divert stream into sampling container ⫸ Grab samples for uniformity testing Answer: 3 grab samples required ⫸ Sample size for casting 3 100mm x 200mm cylinders Answer: Minimum 20L sample size needed ⫸ Sample size for casting 150mm x 300mm cylinders Answer: Minimum 30L sample size needed ⫸ Sample size for casting 150mm x 150mm x 535mm beams Answer: Minimum 55L sample size needed ⫸ Extra sample for more than 3 cylinders/specimens Answer: Volume of cylinders/specimens plus 10% extra needed ⫸ Time for obtaining, transporting, and remixing sample Answer: Allowed 10 minutes for the process

⫸ Aggregate larger than appropriate Answer: Must be wet-sieved before testing ⫸ Information required on reports Answer: Includes conc mix no, sample details, project info, technician, and deviations ⫸ Air Content in concrete Answer: Volume of air voids in plastic concrete, excluding pore space in aggregate ⫸ Slump in concrete Answer: Measure of consistency post-removal of slump cone, indicating subsidence ⫸ Slump Flow in concrete Answer: Horizontal spread post-removal of slump cone, indicating fluidity ⫸ Water-to-cementing materials ratios Answer: 3 ratios needed for concrete trial mixes ⫸ Stable temperature before mixing concrete Answer: 23 C +/- 2 C considered stable ⫸ Storage of cementing materials Answer: In dry, moisture-proof containers ⫸ Surface moisture in aggregate Answer: Sample size of 500g-1000g for obtaining surface moisture

⫸ Internal Vibration Answer: Method for concrete compaction with specific dimensions and insertions. ⫸ Specimen Removal Time Answer: Specimens removed from moulds after 20 +/- 4 hrs. ⫸ Initial Curing Temperature Answer: Maintained between 15 and 25 degrees C. ⫸ Extended Demoulding Time Answer: Extended to 76hrs for strength <35MPa. ⫸ Transport After Initial Curing Answer: Wait 20hrs before transporting specimens. ⫸ Flexural Test Specimen Size Answer: Specific dimensions and ratios for flexural test specimens. ⫸ Placing Concrete - Flexural Test Answer: Mould filling instructions based on thickness. ⫸ Rodding Flex Specimens Answer: Rodding instructions for flexural test specimens. ⫸ Internal Vibration for Flexural Specimens Answer: Interval guidelines for internal vibration during specimen preparation.

⫸ Flexural Test Specimen Initial Cure Answer: Cure for 48 +/- 4 hrs before demoulding. ⫸ Tampering Rod Dimensions Answer: Specified dimensions for air content test tampering rod. ⫸ Measuring Bowl Answer: Rigid bowl specifications for limiting expansion. ⫸ Air Gauge Dial Answer: Allows direct reading of air volumes. ⫸ Calibration Cylinder Answer: Volume range relative to base container volume. ⫸ Air Meter Readings Answer: Readings to the nearest 0.1%. ⫸ Air Test Time Limit Answer: Conduct air test within 10 minutes of sample collection. ⫸ Air Meter Rodding Answer: Number of rod strokes based on bowl size. ⫸ Slump on Mixtures >40mm Aggregate Answer: Procedure for conducting slump test on larger aggregates.