The assignment of civil engineering contain these points:Compressive Strength, Concrete Column, Non-Air-Entrained Concrete, Data, Specified Slump, Properties, Absorption, Dry Bulk Specific Gravity, Natural Moisture Content, Dry-Rodded Unit Weight
Typology: Exercises
1 / 1
This page cannot be seen from the preview
Don't miss anything!

A concrete mix for a concrete column exposed to mild climate is to be designed according to the ACI Absolute Volume Method. A non-air-entrained concrete is to be used. The specified 28- day compressive strength (f’ (^) c) is 4,800 psi. No past data are available to establish the standard of deviation of the compressive strength of the concrete. The specified slump of the fresh concrete is 3 to 4 inches. The cement used will be a Type I cement. Assume the following properties for the aggregates: Coarse Agg. Fine Agg. Dry Bulk Specific Gravity 2.35 2. Absorption 4.9% 0.4% Natural Moisture Content 2.5% 0.2% Dry-Rodded Unit Weight 88 pcf - Nominal Maximum Aggregate Size 3/4 inch - Fineness Modulus - 2.