DTHY 405 Final.docx....DTHY 405 Final.docx, Exams of Nursing

DTHY 405 Final.docx....DTHY 405 Final.docx

Typology: Exams

2025/2026

Available from 03/28/2026

real-grades
real-grades 🇬🇧

5

(3)

11K documents

1 / 16

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
DTHY 405 Final
When a person in is the pre-contemplative stage of change, where are they on the
the importance ruler? - correct answer0
All are basic principles that are encouraged during motivational interviewing
EXCEPT:
Demonstrate genuine concern and empathy
Reflect what the person is saying by paraphrasing
Strive to understand the person's situation
A tough approach is the best approach - correct answer A tough approach is the
best approach
What is your task as a health care provider trying to encourage tobacco cessation
when the individual is in a pre-contemplation change stage? - correct answer
Recommend quitting to the individual
When an individual is in the action stage of change, where are they on the
importance ruler? - correct answer10
When an individual is thinking about making a change, what change stage is he/she
in? - correct answer contemplation
What is your task as a health care provider trying to encourage tobacco cessation
when the individual is in a preparation change stage? - correct answer Set a quit
date
What is your task as a health care provider trying to encourage tobacco cessation
when the individual is in a maintenance change stage? - correct answer Identify
strategies to prevent relapse
The use of reflective listening in motivational interviewing lets the person know that
you are listening and understand their point of view. - correct answer True
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff

Partial preview of the text

Download DTHY 405 Final.docx....DTHY 405 Final.docx and more Exams Nursing in PDF only on Docsity!

DTHY 405 Final

When a person in is the pre-contemplative stage of change, where are they on the the importance ruler? - correct answer All are basic principles that are encouraged during motivational interviewing EXCEPT: Demonstrate genuine concern and empathy Reflect what the person is saying by paraphrasing Strive to understand the person's situation A tough approach is the best approach - correct answer A tough approach is the best approach What is your task as a health care provider trying to encourage tobacco cessation when the individual is in a pre-contemplation change stage? - correct answer Recommend quitting to the individual When an individual is in the action stage of change, where are they on the importance ruler? - correct answer When an individual is thinking about making a change, what change stage is he/she in? - correct answer contemplation What is your task as a health care provider trying to encourage tobacco cessation when the individual is in a preparation change stage? - correct answer Set a quit date What is your task as a health care provider trying to encourage tobacco cessation when the individual is in a maintenance change stage? - correct answer Identify strategies to prevent relapse The use of reflective listening in motivational interviewing lets the person know that you are listening and understand their point of view. - correct answer True

Knowledge about a habit one needs to change will always be a motivator for that person to change. - correct answer False What is your task as a health care provider trying to encourage tobacco cessation when the individual is in a contemplation change stage? - correct answer Have tobacco user evaluate pros and cons of tobacco use The following are examples of a helpful tobacco cessation professional EXCEPT one: Attempt to understand the person's frame of reference and motivation Affirming person's freedom of choice Provider decides the right time for patient to change Eliciting and reinforcing person's self motivational statements - correct answer Provider decides the right time for patient to change Increasing the power setting on the ultrasonic device increases the displacement amplitude of the tip, shortening the stroke - correct answer False Magnetostrictive devices (cavitron) employ an alternating electromagnetic field which causes magnetization resulting in elongation and contraction and high- frequency oscillation of the insert tip. Which metal is utilized within the Cavitron insert for magnetization to occur when in contact with the copper wire in the hand piece? - correct answer Nickel The magnetostrictive scalers utilized at WVU are 30 kilohertz. Convert these cycle per second (cps) mechanical vibrations to hertz. - correct answer30,000cps There are three operational variables to assess and adjust for effective calculus removal/root debridement/biofilm removal. Match the operational variable tern with the best description/definition. - correct answer power setting : length of oscillating strokes to affect the displacement amplitude of the tip water flow : Cool and maximize cavitation and microstraming activity at the activated tip

Select the best instrument for efficient periodontal therapy in tight grooves and furcation entrances. - correct answer narrow-diameter (slim), curved ultrasonic tip In the past, magnetostrictive scalers were avoided in patients with pace makers, vagus nerve stimulators for epilepsy or on pediatric patients. Modern shielded pacemaker's/vagus nerve stimulator's manufacturers and cardiologists are not concerned of the risk of electromagnetic interference with the function of these devices. On pediatric patients, sensitivity and pulpitis can be avoided by maintaining adequate water irrigation, tip movement with light pressure, and reduced power settings during usage. - correct answer True Select the appropriate sites to assess furcation involvement on mandibular molars. - correct answer mid-buccal, mid-lingual Valid research studies reflect healing following periodontal therapy analyzing the probe depth reduction in sites that were 5mm or greater prior to treatment and ignore the sites that were 4mm or less prior to treatment. This show a true reduction in probing depths rather than an average of healthy sites (<5mm) and unhealthy sites (>5mm) together which can minimize the amount of improvement. - correct answer True Select the reason that mean probing depth calculations for the entire mouth may make the magnitude of probing depth reduction seem less effective following non- surgical periodontal therapy. - correct answer mean probing depths is an average of all pockets in the mouth (4mm). Including the shallow pockets in the average calculation reduces the magnitude of depth reduction that occurred at the sites that were deep prior to treatment. Select the ultrasonic scaling technique(s) that one should use to minimize surface roughness on existing restorations in the area needing periodontal therapy. - correct answer keep tip moving multiple light strokes don't apply tip point directly against the restoration surface When you diagnose a periodontal condition, it is important to ask the patient if they have any other planned dental treatment so that you can make that dental provider aware of the active infection which may result in an alteration to the treatment plan. - correct answer True

There is no evidence to suggest that dental and/or periodontal treatment is harmful to the pregnant woman or her developing fetus. - correct answer True Select the appropriate sites to assess furcation involvement on maxillary molars. - correct answer mid-buccal, mesio-palatal, disto-palatal The force that should be applied when performing periodontal probing is 0. Newton. What can a provider do to equate .25 Newton to an activity? - correct answer Practice depressing skin on pad of thumb by 1mm with periodontal probe A straight insert tip is best utilized when instrumenting the coronal surfaces of teeth or on flat root surfaces of anterior teeth with moderate amounts of calculus. - correct answer True What increases the cavitation activity that occurs at the clinically active area of a slim diameter tip? - correct answer Lateral pressure An ultrasonic insert tip's geometry, affects the clinician's ability to: - correct answer access the treatment site make adequate contact with the tooth surface Match the ultrasonic tip design key element term with the appropriate definition - correct answer Profile : Number of bends in tip, single bend, double bend, triple bend Shape : Contour of the active area in cross section; rectangular, circular Dimension : Width or diameter of the active area of the tip; standard, slim, ultra- slim Geometry : Number of planes crossed by the shank; straight, curved

Straight Ultrasonic Insert Tip's Access : Coronal surfaces; anterior roots Based on the key element of an ultrasonic insert tip's profile, which design is best for improved adaptation around line angles and interproximal spaces? - correct answer double or triple bend You are scaling in the Maxillary Left Buccal Quadrant. Which area specific curved tip is appropriately utilized? - correct answer Right Curved You begin your sequenced scaling in the Maxillary Right Buccal Quadrant. Which area specific curved tip is appropriately utilized? - correct answer Left Curved You are performing scaling in the Mandibular Right Buccal Quadrant. Which area specific curved tip is appropriately utilized? - correct answer Right Curved A curved insert tip is best utilized when instrumenting the root surfaces of posterior teeth with light calculus and biofilm. - correct answer True What are the four key elements of design of an ultrasonic insert tip that are assessed to make the correct tip selection for effective root debridement? - correct answer profile, geometry, shape, dimension The shape of an ultrasonic insert tip can be either rectangular or circular in cross section. The circular insert tip is more beneficial to the removal of heavy, tenacious calculus. - correct answer The first statement is true. The second statement is false. Ultrasonic Insert Tips that are designed for specifically for safe debridement of dental implants are include: - correct answer Plastic coated Carbon fiber There are three diameters of ultrasonic inserts; standard, slim and ultraslim. Match the name that these 3 diameters are referred to based on their dimension. - correct answer ultraslim : extra-thin tip

standard : traditional or scaling tip slim : thin, modified, micro-ultrasonic or period tip Select the ultrasonic insert tip's diameter that is most efficacious with moderate to heavy calculus removal when it is oscillating against calculus, not root surface. - correct answer Standard The point of an ultrasonic tip exerts a very concentrated output of energy. Since all surface of the insert can be utilized for calculus and biofilm removal, adapt the point of the ultrasonic insert tip toward the root for effective root debridement. - correct answer The first statement is true. The second statement is false. Regarding ultrasonic insert tip selection, choose the best for removal/reduction of moderate-heavy calculus to ensure adequate penetration to the base of the pocket.

  • correct answer standard, 1 bend Based on an ultrasonic insert tip's profile, which profile is best for interproximal spaces with shallow pockets? - correct answer3 bends In regards to the two staged approach to ultrasonic periodontal instrumentation's tip diameter, the ________ insert is utilized during the scaling stage versus the _____ insert during the debridement stage. - correct answer standard, slim or ultraslim Between ultrasonic and hand instrumentation, which requires the lateral pressure to be light maintaining contact with the tooth? - correct answer Ultrasonic Between ultrasonic and hand instrumentation, which requires an intermittent and apico-coronal in direction working stroke? - correct answer Hand A vertical ultrasonic adaption is parallel to the long axis of the tooth with the point of the tip directed apically, toward the pocket. Choose the indication for use with vertical adaption. - correct answer subgingival and supragingival surfaces excluding interproximal spaces using any surface of the tip

constant As the angulation of the active tip to the tooth surface increases, there is also an increase in root surface loss/damage/defect even on a low power setting. - correct answer True In regards to the two staged approach to ultrasonic periodontal instrumentation's angulation, the ________ angulation is utilized during the scaling stage versus the _____ angulation during the debridement stage. - correct answer0-15 degree, 0- degree A horizontal ultrasonic adaption is perpendicular to the long axis of the tooth. Choose the indication for use with horizontal adaption. - correct answer interproximal space using back or face of the tip An oblique ultrasonic adaption is oblique or off center laterally to the long axis of the tooth. Choose the indication for use with oblique adaption. - correct answer utilized for manual instrumentation and not recommended for ultrasonic instrumentation except at line angle when changing from vertical to horizontal adaptation For pockets equal to or greater than 4mm, choose the correct technique to avoid incomplete subgingival instrumentation. - correct answer channel In regard to the two staged approach to ultrasonic periodontal instrumentation's lateral pressure, utilize_____ degree with a wider tip during the scaling stage and _____ degree with a slim tip during the debridement stage. - correct answerless than or equal to .5N; greater than 1-2 N Between ultrasonic and hand instrumentation, which requires a firm modified pen grasp and a fulcrum in the immediate treatment area to leverage the working stroke? - correct answer Hand Select the correct adaption of an ultrasonic tip to the matching text below: - correct answer Horizontal Adaption : perpendicular to long axis of tooth, used primarily in interproximal space utilizing the back and face of the active tip

Vertical Adaption : preferred during ultrasonic debridement for access to base of pocket, increase surface area debrided per stroke and easy adaption of any surface Oblique Adaption : Lateral surface of tip diagonal to long axis of tooth, utilized during transition of tip at the line angles Between ultrasonic and hand instrumentation, which adapts the lateral surface of the tip in an oblique orientation? - correct answer Hand To provide efficient execution of instrumentation, the appropriate strategy for instrumentation sequencing is to work by ________________. This avoids the operator having to change the ultrasonic tip/operator position needed for the location in mouth and the two stage instrumentation of calculus removal first, followed by debridement secondly. - correct answer sextant In regards to instrument sequencing for both left and right-handed operators, posterior sextant instrumentation begins on the most anterior tooth and advances posteriorly, while anterior sextant instrumentation begins on the most posterior tooth and advances anteriorly. - correct answer False The appropriate ultrasonic insert for moderate to heavy calculus removal in the maxillary right buccal sextant is: - correct answer Standard straight The appropriate point of adaptation and type of stroke utilized when beginning in the maxillary right buccal sextant area #2 is: - correct answer distobuccal line angle; horizontal stroke As the insert tip crosses the distal buccal line angle of #2, transition toward the distal root surface with ________ adaptation and _______ stroke. - correct answer vertical; oblique Once in the distal interproximal space on the crown surface of #2, utilize a ___________ adaptation with the face of the tip against the distal surface and stroke __________. - correct answer horizontal; vertically

In the mandibular anterior lingual sextant, begin ultrasonic use at the tooth furthest away from you as the operator. With proper instrumentation sequencing, you will end on the tooth closest to you in that sextant. - correct answer true Starting with an active tip, the appropriate point of adaptation is at the _______ of the tooth utilizing _______ strokes. One can vertically adapt either the lateral side or back of tip, determined by which adapts to the area the best. - correct answer midline, horizontal As the tip crosses the distolingual line angle of the canine, transition to the distal root surface by maintaining a _________ adaptation of lateral surface of tip to the distal aspect of the tooth. - correct answer vertical Once transitioned to the distal interproximal space of the canine's crown surface, utilize a __________ adaptation with the _______of the tip stroking vertically. - correct answer horizontal, face Next, cross the line angle and proceed across the lingual aspect of the tooth with __________ strokes to advance tip subgingivally and mesially across lingual surface. - correct answer horizontal Utilize slightly oblique at the mesial line angle and transition to the _____ of the tip advance subgingivally and toward facial until hindered by the contact point. - correct answerback Next transition to ________________ adaptation keeping the back of the tip adapted to the mesial of the canine and stroke _________ against the mesial surface. Proceed through the sextant with this instrumentation sequencing. - correct answer horizontal; vertically Which tip is best adapted to the mesial furcation of #3 from the lingual or palatal aspect? - correct answer right curved To ultrasonically scale the mesial furcation from the lingual aspect, maintain adaptation of the __________ surface of tip at 0 degree angulation to the dome of the furcation and debride the dome with short, in and out strokes. - correct answer lateral

Once complete with the mesial dome of #3 furcation, the internal surface of the palatal root dome is best scaled with the ______of the tip in an oblique or vertical pattern. - correct answerback Next sequence from the dome to the mesial buccal root and adapt the ________ surface of the tip with a _________ stroke. This same adaptation and stroke is then applied to the palatal root. - correct answer lateral, vertical Select the appropriate administration instructions for Phos-Flur Rinse®. - correct answer Use once a day after brushing teeth with toothpaste. Vigorously swish 10 mL of rinse between teeth for one minute and then spit out. Select the remineralizing product with the active ingredients, 0.2% Sodium Fluoride with Casein Phosphopeptide (CPP) and Amorphous Calcium Phosphate (ACP). - correct answer MI Paste Plus Select the active ingredient(s) in Novamin products. - correct answer Amorphous Calcium Sodium Phosphosilicate (CSPS) Select the remineralizing product with the active ingredient, 0.4% stannous fluoride gel - correct answer Gel Kam Select the Prevident 5000 product with the active ingredients: 1.1% Sodium Fluoride, Fluorigard Technology, & Tricalcium Phosphate - correct answer President 5000 Booster Plus Match the term with the appropriate definition: - correct answer Demineralization : stage of dental caries process in which calcium and phosphate minerals are dissolved from the tooth structure by oral biofilm acids Remineralization : Process of replenishing calcium, phosphate and fluoride ions to damaged tooth structure

Select the active ingredients in Clinpro 5000 - correct answer1.1% sodium fluoride and Tri - Calcium Phosphate Select the agonist which stimulates certain nerves to increase the amount of saliva you produce, making it easier and more comfortable to speak and swallow. - correct answer Cholinergic Which salivary substitute contains a catechin-containing natural formula and xylitol.

  • correct answer Mighteaflow