E1 RESIDENTIAL ELECTRICAL
INSPECTOR QUESTIONS WITH
CORRECT ANSWERS 2026
Electrical devices operating at less than ___ volts and not
supplying more than ___ watts of energy shall be exempt from
requiring an electrical permit. - correct answer-25,50
Section R105.2 Electrical #4
Who has the authority to give permission to provide temporary
power? - correct answer-Building Official
Section R107.3
A ______ conductor is a conductor that is encased within a
material or has a thickness NOT recognized by the IRC as
electrical insulation. - correct answer-Covered
Definitions Section E3501 - Conductor, Covered
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22
pf23

Partial preview of the text

Download E1 RESIDENTIAL ELECTRICAL INSPECTOR QUESTIONS WITH CORRECT ANSWERS 2026 and more Exams Electrical Engineering in PDF only on Docsity!

E1 RESIDENTIAL ELECTRICAL

INSPECTOR QUESTIONS WITH

CORRECT ANSWERS 2026

Electrical devices operating at less than ___ volts and not supplying more than ___ watts of energy shall be exempt from requiring an electrical permit. - correct answer-25, Section R105.2 Electrical # Who has the authority to give permission to provide temporary power? - correct answer-Building Official Section R107. A ______ conductor is a conductor that is encased within a material or has a thickness NOT recognized by the IRC as electrical insulation. - correct answer-Covered Definitions Section E3501 - Conductor, Covered

An approved enclosure shall be used to guard people against accidental contact with energized parts that operate at a minimum of ______ volts. - correct answer- 50 Section E3404. When splicing, terminating, or connecting a conductor to a fixture or device the minimum length of free conductor required at an outlet, junction box, or switch point shall be at least ____ inches?

  • correct answer- 6 Section E3406.11. Electrical copper conductors used for feeders and branch circuits shall have a minimum size of ______. - correct answer-No. 14 AWG Section E3406. An overhead service conductor spanning over a driveway shall maintain a minimum vertical clearance of ____ feet from final grade. - correct answer- 12

True or False. The disconnecting means for an electrical service cannot be installed in a bathroom. - correct answer-True Section E3601.6. A metal underground water pipe must be in direct contact with the earth for a minimum of ___ feet to be considered as a grounding electrode. - correct answer- 10 Section E3608.1. A ground ring can be used as a grounding electrode if located a minimum ___ inches below the earth and at least ___ feet of bare copper wire no smaller than ___ AWG is used. - correct answer- 30, 20, 2 Section E3608.1. Two grounding rods used in one grounding electrode system must be located at least ___ feet apart. - correct answer- 6 Section E3608.

When a rod is used as a grounding electrode, it shall not be less than ___ feet in length. - correct answer- 8 Section E3608.1. When a rod used as a grounding electrode is buried in a trench, what must the minimum depth of the trench be? - correct answer- 30 Inches Section E3608.1.4. A supplemental grounding electrode is not required when the single grounding electrode provided has a resistance of ___ ohms or less to the earth. - correct answer- 25 Section E3608.4 Exception A minimum unit load of ___ volt-amperes shall be used to size feeder conductors for lighting and general use receptacle loads per square foot of floor area. - correct answer- 3

No. 14 copper conductors are permitted to have a maximum overcurrent protection device rating of many amps? - correct answer-15 amps Table E3705.5. Which of the following is considered to be a standard ampere rating for fuses? 25amps, 55amps, 75amps, 95amps - correct answer-25amps Section E3705. What is the minimum size a circuit conductor is required to be when a branch circuit having two or more outlets is rated at 20 amps? - correct answer-12 AWG Table E3702. Fixed utilization equipment shall be supplied with a minimum ___- ampere branch circuit. - correct answer- 30

Section E3702. True or False. An electric space heating and water heating appliance shall be considered as a continuous loads. - correct answer-True Section E3702. Lighting units are permitted to be supplied with either a ___- ampere or ___-ampere branch circuit. - correct answer-15, Section E3702. The ampacity of branch circuit conductors shall not be less than ___ percent of the motors full-load current rating when supplying a single motor. - correct answer- 125 Section E3702.

Section E3907. Cabinets and Panelboards installed in a wall of noncombustible material such as concrete or tile shall be installed to where the front edge of the cabinet is not set back more than ___ inch from the finished surface material. - correct answer-1/ Section E3907. Openings in which conductors enter ______ shall be closed in an approved manner. - correct answer-cabinets, panelboards, meter sockets Section E3907. Where cables are protected from physical damage by PVC rigid nonmetallic conduit, it shall be a minimum Schedule ___. - correct answer- 80 Section E3802.3.

Cables not sleeved yet exposed to direct sunlight shall be listed and marked as "______". - correct answer-Sunlight Resistant Section E3802.3. When determining the required number of receptacle outlets within a room, floor receptacle outlets cannot be counted unless they are located within ____ inches from the wall. - correct answer- 18 Section E3901.2. Bathrooms shall have at least one wall receptacle outlet installed within ___ inches of the outside edge of a lavatory basin. - correct answer- 36 Section E3901. Receptacle outlets shall be equipped with ground-fault circuit interrupter protection when located within ___ feet from the outside edge of a sink. - correct answer- 6

When thread-forming machine screws are used to connect grounding conductors to metal boxes, they shall be engaged not less than ___ thread(s) in the enclosure. - correct answer-Two Section E3908.15 # At no point shall an equipment bonding jumper on the load side of an overcurrent device be smaller than ____ AWG. - correct answer-No. 14 Section E3908. A trash compactor appliance listed to be connected with a flexible cord shall have a minimum cord length of ____ inches and a maximum cord length of ____ inches. - correct answer-36, 48 Table E4101. An electrical circuit that energizes signaling equipment is known as a _______. - correct answer-Signaling Circuit Section E4301 - Definitions

Switches and circuit breakers must be installed where the center of the grip of the operating handle of the switch or circuit breaker is located not more than ___ feet ___ inches above the working platform. - correct answer-6, 7 Section E4001. True or False. Snap switches that are rated for 20 amperes or less and directly connected to aluminum conductors must be marked CO/ALR. - correct answer-True Section E4001. Receptacles located more than ___ feet above the floor are NOT required to be tamper resistant. - correct answer-5. Section E4002.14 Exception # True or False. Metal faceplates for receptacles are NOT required to be grounded. - correct answer-False

A flexible cord for a cord-and-plug connected trash compactor must have a minimum cord length of ____ and maximum length of ____ inches. - correct answer-36, 48 Section E4101.3, Table E4101. Appliances and equipment shall be installed in accordance with which of the following? - correct answer-Manufacturer's installation instructions Section E4101. A ___ ampere-rated receptacle outlet servicing heating, air- conditioning and refrigeration equipment must be installed at an accessible location. - correct answer-15 & 20 Section E3901. A receptacle outlet servicing heating, air-conditioning and refrigeration equipment must be located on the same level and within ____ feet from the equipment. - correct answer- 25

Section E3901. Receptacles located within ___ feet from the inside wall of a swimming pool must be protected by a ground-fault circuit- interrupter. - correct answer- 20 Section E4203.1. At least one receptacle must be located between ___ feet and ___ feet from the inside wall of an indoor spa and hot tub. - correct answer-6, 10 Section E4203.1. Underground wiring installed in a rigid metal conduit and located within 5 feet horizontally from the inside wall of a swimming pool shall have a minimum burial depth of ___ inches. - correct answer- 6 Section E4203.7, Table E4203.

Section E3905.12.1, E3905.12.1.1, Table E3905.12. Boxes installed in openings of noncombustible surfaces with a flush-type cover or faceplate shall have no gap greater than ___ inch around the edge of the box. - correct answer-1/ Section E3906. Non-current-carrying metal parts of fixed equipment supplied by or enclosing conductors likely to become energized must be connected to the equipment grounding conductor when located within ___ feet vertically or ___ horizontally of the earth and where subject to contact by persons. - correct answer-8, 5 Section E3908.2 # True or False. Grounded Circuit conductors shall NOT be used for grounding noncurrent-carrying metal parts or equipment on the load side of the service disconnecting means. - correct answer- True Section E3908.

Flexible cords shall NOT run through which of the following locations? (Holes in a wall, suspended ceilings, dropped floors, all of the above) - correct answer-All of the above Section E3909. Type CL2X limited-use cables are permitted to be installed without a raceway when have a diameter less than ___ inch. - correct answer-1/ Section E4303.2. General-use snap switches that control motor loads shall not exceed ___ percent of the ampere rating of the switch at its rated voltage. - correct answer- 80 Section E4001.1 # True or False. When single-throw switches are operated vertically, the up position of the handle shall be in the off position.

  • correct answer-False