Illinois Private Sewage Contractor Exam Questions and Answers, Exams of Nursing

A comprehensive set of questions and answers related to the illinois private sewage contractor exam. It covers essential topics such as private sewage disposal systems, domestic sewage, approved pipe materials, septic tank regulations, and subsurface seepage systems. This study guide is designed to help contractors prepare for the exam by testing their knowledge of key concepts and regulations related to sewage disposal in illinois. It includes detailed explanations and correct answers for each question, making it a valuable resource for exam preparation. The document also covers topics such as variance permits, experimental permits, and soil investigation requirements.

Typology: Exams

2025/2026

Available from 10/17/2025

aim-higher
aim-higher 🇺🇸

5

(2)

9.8K documents

1 / 14

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
Illinois Private Sewage Contractor
Exam with correct answers
Private Sewage Disposal System - correct answer✔✔Any sewage handling or
treatment facility receiving domestic
sewage from less than 15 people or population equivalent (less than 1,500
gallons} and having a ground
surface discharge or any sewage handling or treatment facility receiving
domestic sewage and having
no ground surface discharge
Domestic Sewage - correct answer✔✔Waste water derived principally from
dwellings, business, or office buildings, institutions, food service
establishments, and similar facilities
Clear Water Permitted to Drain in Septic System - correct answer✔✔Cooling
water
Groundwater
Discharge from roof drains
Discharge from footing tile
Condensate waste from refrigeration system
Condensate from steam heating system
Backwash from Water Softener
Prohibited Materials for Septic System - correct answer✔✔Automotive
Grease
Oil
Solvents
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe

Partial preview of the text

Download Illinois Private Sewage Contractor Exam Questions and Answers and more Exams Nursing in PDF only on Docsity!

Illinois Private Sewage Contractor

Exam with correct answers

Private Sewage Disposal System - correct answer✔✔Any sewage handling or treatment facility receiving domestic sewage from less than 15 people or population equivalent (less than 1, gallons} and having a ground surface discharge or any sewage handling or treatment facility receiving domestic sewage and having no ground surface discharge Domestic Sewage - correct answer✔✔Waste water derived principally from dwellings, business, or office buildings, institutions, food service establishments, and similar facilities Clear Water Permitted to Drain in Septic System - correct answer✔✔Cooling water Groundwater Discharge from roof drains Discharge from footing tile Condensate waste from refrigeration system Condensate from steam heating system Backwash from Water Softener Prohibited Materials for Septic System - correct answer✔✔Automotive Grease Oil Solvents

Chemicals The use of a private sewage disposal system to service more than one property is: - correct answer✔✔Prohibited except when common property under joint ownership is provided or where the system is under public jurisdiction Sewers are to be installed at least ______ feet horizontally from an existing or proposed water line. - correct answer✔✔10 Feet Horizontally If the distance between the sewer and water line must be less than 10 feet horizontally then the sewer line must be at least __________ inches below the invert of the water line. - correct answer✔✔18" Approved Pipe Materials - correct answer✔✔Ductile Iron, Vitrified Clay, or Plastic at least 4" in diameter Raw or improperly treated domestic sewage cannot be discharged into: - correct answer✔✔Farm tiles Streams Rivers Ponds Lakes Other collectors of water. Septic Tanks cannot be located: - correct answer✔✔Where surface water will accumulate or near: Driveways Accessory building

When installing a new or innovative type of sewage disposal system, what type of permit shall be required? - correct answer✔✔Experimental Permit A solids retention tank is required before a septic tank if: - correct answer✔✔A garbage grinder is used The minimum liquid depth of septic tank is: - correct answer✔✔42" The maximum liquid depth of a septic tank is: - correct answer✔✔72" Inlet & Outlet Openings Shall Be: - correct answer✔✔Cast-In Watertight The invert of the inlet needs to be at least how many inches above the liquid level? - correct answer✔✔2" How is the liquid level of the tank determined? - correct answer✔✔Equal to the Invert of the Outlet The inlet baffle extends ______ inches below the liquid level. - correct answer✔✔6" Below the Liquid Level The outlet baffle needs to extend to a depth equal to what percent of the liquid depth? - correct answer✔✔40% An outlet baffle for a tank with a liquid depth of 60" need to extend how many inches below the liquid depth? - correct answer✔✔24" 60" X 40% = 24"

Maximum distance from the inlet wall to the inlet baffle - correct answer✔✔12" Maximum distance from the outlet wall to the outlet baffle - correct answer✔✔6" Distance from the top of the baffle to the bottom of the lid - correct answer✔✔1" - 3" Slip in baffles shall extend: - correct answer✔✔The full width of the tank Semi-Circular Baffles (V) shall have sides that fit tightly against: - correct answer✔✔The tank wall The vent for the baffle shall be equal in size to: - correct answer✔✔The building sewer Minimum Inlet Baffle Size Diameter - correct answer✔✔6" Minimum Outlet Baffle Size Diameter - correct answer✔✔4" A single compartment tank needs to have a gas deflection baffle provided __________ the outlet of the baffle. - correct answer✔✔Below Access Manhole Requirements - correct answer✔✔Above the Inlet of the Tank Above the Outlet of the Tank 12" in Diameter

Tanks are to be set level to +/- ______ inches in any direction and backfilled to prevent floating or drifting. - correct answer✔✔1/2" There are to be no connections within the area of __________. - correct answer✔✔The over dig around the tank If access openings are at or below the season high water table, they shall be _____________. - correct answer✔✔Water-Tight Abandoned Treatment Units shall be: - correct answer✔✔Crumbled and filled with sand or soil Septic tanks that are removed from the earth shall be replaced with: - correct answer✔✔Soil A distribution box can be installed: - correct answer✔✔Between a septic tank/aeration tank and a subsurface seepage system/buried sand filter The distribution box needs to provide for: - correct answer✔✔Equal distribution of flow to the subsurface system The distribution box shall be constructed of: - correct answer✔✔Watertight, Non-Corrosive Material Subsurface seepage systems shall be designed based on: - correct answer✔✔The absorption capacity of the soil Who is qualified to conduct a soil investigation? - correct answer✔✔Soil Classifier

Licensed Professional Engineer Local Health Department Employee (3 Years Approving Systems with 6 Hours of Soils Coursework) Local Health Department Employee (5 Years Direct Supervision) A minimum of ______ soil borings at least ______ feet apart are to be located within the area of the proposed subsurface seepage system. - correct answer✔✔3 Soil Borings 50 Feet Apart Each soil boring shall extend at least ________ inches below the surface. - correct answer✔✔At least 60" Below the Surface One of the soil borings shall be located: - correct answer✔✔At the lowest elevation of the subsurface seepage system Domestic sewage or effluent from a private sewage disposal system cannot be discharged into a: - correct answer✔✔Well Cistern Basement Underground Mine Cave Sinkhole Tunnel The bottom of a subsurface field, each trench, and its distribution levels are to be: - correct answer✔✔Level to +/- 1 inch

The bedding material extends the full width of the trench to a depth at least ______ inches below the line and _______ inches above the line. - correct answer✔✔6" below 2" above The ends of the trenches are to be looped except when using a: - correct answer✔✔Serial Distribution System Approved corrugated polyethylene tubing must be _____ inches or _____ inches in diameter. - correct answer✔✔8" or 10" On a serial distribution system, there needs to be a minimum of _______ feet of undisturbed earth between the septic tank and the first trench and ______ feet between each trench. - correct answer✔✔5" Feet from the Septic 6" from the next trench The total bottom area for a seepage bed is ________ times the area determined for a gravel seepage field system. - correct answer✔✔1.5x the area Buried sand filters need to have _________ square feet per bed room when on a septic system which is cut by ________ on aerobic system. - correct answer✔✔200 Square Feet 1/ The sand filter needs to be dosed ______ times per day with equal flows which cannot exceed the design capacity. - correct answer✔✔4 times A buried sand filter needs to be designed for a minimum of ________ gallons/day. - correct answer✔✔100 gallons per day

The sand filter media needs to be a minimum of ______ inches thick, and clear of clay and silt. - correct answer✔✔24" Collection lines need to have a slope of ________ inches per 100 feet with a collection line every _____ feet with caps on the top of the collection line. - correct answer✔✔6" per 100 feet 10' Illinois Raised Filter Beds are constructed using: - correct answer✔✔Batch Aeration System and a Filter Bed The aeration tank volume for a residential system is to be ______ times greater than the average daily wastewater flow in residential applications and ______ times greater in commercial applications. - correct answer✔✔2x Residential 3x Commercial The filter loading rate for residential systems is: - correct answer✔✔ 4 Gallons per Square Foot per Day Filter beds cannot exceed ________ square feet. - correct answer✔✔ 600 Square Feet Aerobic Treatment Plants need to be followed by which type of system? - correct answer✔✔Subsurface Seepage System Sand Filter Waste Stabilization Pond The depth of waste stabilization pond shall be between ________ and ______ feet. - correct answer✔✔3' and 5'

A sanitary dump station with no disposal system is to be designed for _____ gallons per day for each RV site. - correct answer✔✔140 Gallons per day per site Swimming pool waste may not be discharged into a private sewage disposal system if: - correct answer✔✔The system contains domestic sewage Single Family Dwelling Sewage Flow Rate - correct answer✔✔200 Gallons Per Day Per Bedroom Multi Family Dwelling Sewage Flow Rate - correct answer✔✔200 Gallons Per Day Per Bedroom Individual Mobile Home Sewage Flow Rate - correct answer✔✔200 Gallons Per Day Per Bedroom Campground Sewage Flow Rate - correct answer✔✔150 Gallons Per Day Per Site Commercial Sewage Flow Rate - correct answer✔✔400 Gallons Per Day Per Toilet Minimum Volume of Septic Tank in Residential Application - correct answer✔✔2 Bedrooms = 750 Gallons 3 Bedrooms = 1000 Gallons 4 Bedrooms = 1250 Gallons 5 Bedrooms = 1500 Gallons 6 Bedrooms = 1750 Gallons 7 Bedrooms = 2000 Gallons

Gravelless System Construction Requirements - correct answer✔✔Max Trench Length = 100 Feet Minimum Trench Width = 18" Maximum Trench Width = 24" Minimum Trench Depth = 18" Maximum Trench Depth = 24" Trench Slope = Level