Metal Detector Training
Model – Profile advantage V-48
Password settings.
User-1 ---- operator ---- (111111) Six times one.
User-2 ---- Supervisor ---- (222222) Six times two.
User-3 ---- Engineer ---- (333333) Six times Three.
Admin----- (999999) Six times nine.
Engineer Mode:
Change sensitivity
Click setting or key -----add Engineer password--- go to product setting ----
1. Here we can change mode which is different frequency settings. Right now, its Mode-7
which operator on 2 frequencies: 300Khz & 100 Khz.
2. Sensitivity – default is 869 (Max -- 999). Note We have sensitivity -2: 764 which can only
be seen in vector diagram.
3. Phase --- 175.81
We can do reset reject counter and change product, create product etc.
Admin Mode:
1. Edit account password:
Click setting or key -----add Admin password--- Go to advance setting—Access account
management--- Edit account—Select user and change password.
2. To enable Vector diagram:
Click setting or key -----add Admin password--- options installed--- select vector diagram--- click
on start. It will enable vector diagram in product setting screen for 60 mins. Then we need to
start again following same procedure.
3. Restore default setting:
Click setting or key -----add Admin password--- Go to advance setting—system default --- click on
restore default settings.

Partial preview of the text

Download metal detector parameters and more Study notes Physics in PDF only on Docsity!

Metal Detector Training

Model – Profile advantage V- Password settings. User-1 ---- operator ---- (111111) Six times one. User-2 ---- Supervisor ---- (222222) Six times two. User-3 ---- Engineer ---- (333333) Six times Three. Admin----- (999999) Six times nine. Engineer Mode: Change sensitivity Click setting or key -----add Engineer password--- go to product setting ----

  1. Here we can change mode which is different frequency settings. Right now, its Mode- which operator on 2 frequencies: 300Khz & 100 Khz.
  2. Sensitivity – default is 869 (Max -- 999). Note We have sensitivity -2: 764 which can only be seen in vector diagram.
  3. Phase --- 175. We can do reset reject counter and change product, create product etc. Admin Mode:
  4. Edit account password: Click setting or key -----add Admin password--- Go to advance setting—Access account management--- Edit account—Select user and change password.
  5. To enable Vector diagram: Click setting or key -----add Admin password--- options installed--- select vector diagram--- click on start. It will enable vector diagram in product setting screen for 60 mins. Then we need to start again following same procedure.
  6. Restore default setting: Click setting or key -----add Admin password--- Go to advance setting—system default --- click on restore default settings.